The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
HEAT UNIT ADEQUATELY | UNITS #2F, 64.5 DEGREES AND UNIT #3B INADEQUATE HEAT DURING TIME OF INSPECTION | 643 W 62ND ST | COMPLAINT | FAILED | View |
SAFE WORKING CONDITIONS | DEFECTIVE RADIATORS IN UNIT #2F AND UNIT #3B DURING TIME OF INSPECTION RADIATORS GENERATE NO HEAT | 643 W 62ND ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | UNIT #1S MISSING SMOKE DETECTOR | 643 W 62ND ST | COMPLAINT | FAILED | View |
REPAIR OR REPLACE | EAST ELEVTION, REAR DISCONNECTED DOWNSPOUT 18-29-1101.2.1 | 643 W 62ND ST | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | BUILDING NOT REGISTERED 2002-07 | 643 W 62ND ST | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | OWNER/MANAGEMENT INFORMATION NOT POSTED | 643 W 62ND ST | PERIODIC | FAILED | View |
REPAIR ROOF STRUCTURE | EAST EXTERIOR STAIRS ROOF SHEATHING ROTTED | 643 W 62ND ST | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | EAST ELEVATION, EXTERIOR STAIRS COLUMNS MISSING CONCRETE FOUNDATIONS AND STEEL SHOE JOISTS MISSING HANGERS COLUMN 1/2 LAP JOINTS UNDERSIZED 4X4 COLUMNS OVERSPANNED 645 PORCH 1ST AND 2ND FLIGHT OF STAIRS BROKEN TREADS AND RISERS. GUARDRAILS MISSING BOLTS FOR CONNECTION TO MASONRY WALL GUARDRAIL IMPROPER CONTINUOUS LATTICE DESIGN GRADE TO LEVEL 3 GUARDRAIL AT 645 PORCH 2ND LEVEL BROKEN PICKETS IMPROPER WINDING STAIRSPORCH VIEWED FROM ALLEY 643 PORCH NOT VISIBLE OBTAIN PLANS AND PERMIT FOR REPAIR OR REPLACEMENT | 643 W 62ND ST | PERIODIC | FAILED | View |
DWELLING CLEAN AND SANITARY | 643-45 INTERIOR STAIRWELLS, FILTHY | 643 W 62ND ST | PERIODIC | FAILED | View |
INT WALL/CEILING PEELING PAINT | 643-45 INTERIOR STAIRWELLS, LARGE HOLES | 643 W 62ND ST | PERIODIC | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | 643-45 LOOSE AND DAMGED TREADS, 643 BROKEN STRINGER, 645 LANDING LOOSE AND SAGGING INTERIOR STAIRWELLS | 643 W 62ND ST | PERIODIC | FAILED | View |
REPAIR SKYLIGHT | 645 SKYLIGHT, WATER DAMAGE | 643 W 62ND ST | PERIODIC | FAILED | View |
STOP SMOKE, NOXIOUS ODORS | 643 STAIRWELL, NOXIOUS ODORS | 643 W 62ND ST | PERIODIC | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | 643 AND 645 TOP OF INTERIOR STAIRWELL, SMOKE DETECTOR INOPERABLE | 643 W 62ND ST | PERIODIC | FAILED | View |
CHIMNEY CAPPING | REAR EAST ELEVATION, WING WALL SUPPORTING 643 PORCH, WASHED OUT MORTAR AND BROKEN MASONRY | 643 W 62ND ST | PERIODIC | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | 643-45 INTERIOR STAIRWELLS, HOLES AND LARGE CRACKS EXPOSING WOOD LATH | 643 W 62ND ST | PERIODIC | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | INTERIOR OF BUILDING - NO RESPONSE, UNVERIIFED DETECTORS, INTERIOR CONDITIONS AND COMPLAINT OF MISSING SMOKE DETECTOR AT APT. 643 W./ 1N AND RAT INFESTATION. | 643 W 62ND ST | PERIODIC | FAILED | View |
REPAIR LINTELS | WEST ELEVATION AT 645 / 3RD FLOOR WINDOW LINTEL - RUSTED DETERIORATED. PLANS AND PERMIT REQUIRED TO REPAIR LINTEL. | 643 W 62ND ST | PERIODIC | FAILED | View |
TEST ALTERED SYSTEM | (312) 743-0413 | 643 W 62ND ST | COMPLAINT | PASSED | View |
REPAIR COPING | WEST ELEVATION / COPING - MISSING. | 643 W 62ND ST | PERIODIC | FAILED | View |
MAINTAIN WINDOW | WEST ELEVATION 3RD FLOOR WINDOW - MISSING ALUMINUM CAPPING. | 643 W 62ND ST | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | EAST ELEVATION / REAR 3 STORY PORCH AT 643 / 1ST FLOOR GUARD RAIL - ROTTING TOP RAIL. | 643 W 62ND ST | PERIODIC | FAILED | View |
REPAIR WINDOW SILLS | WEST ELEVATION AT 645 / 3RD FLOOR SILLS - WASHED OUT MORTAR. | 643 W 62ND ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR HARDWARE | EAST AND SOUTH BASEMENT DOORS - DO NOT LOCK.SOUTH BASEMENT DOOR - DELAMINATED WOOD VENEER | 643 W 62ND ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | EAST ELEVATION AT 643 BASEMENT TO GRADE / STAIRS - MISSING HANDRAIL. | 643 W 62ND ST | PERIODIC | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | NORTH ELEVATION / 1ST FLOOR WINDOW - BROKEN. | 643 W 62ND ST | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING / OWNER'S ID SIGN - MISSING | 643 W 62ND ST | PERIODIC | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | PERMIT REQUIRED -FOR NEW COPPER PIPES. BASEMENT APT / PERMIT REQUIRED - FOR NEW FURNACE AND PIPES. BASEMENT/ PERMIT REQUIRED - FOR NEW BOILER FOR 13 UNIT BUILDING THAT IS BROKEN AND GOING TO BE REPLACE. | 643 W 62ND ST | COMPLAINT | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | VARIOUS REAR APARTMENT DOORS AT PORCH - SCREEN DOORS MISSING | 643 W 62ND ST | PERIODIC | FAILED | View |
PARAPET | WEST PARAPET - ERODED MORTAR JOINTS. | 643 W 62ND ST | PERIODIC | FAILED | View |
STOP LEAKING WATER | 643 S./ - APT. 2S BATHROOM AND BEDROOM CEILING AND WALLS - WATER LEAK. | 643 W 62ND ST | PERIODIC | FAILED | View |
MICE/RODENTS | BUILDING INFESTED WITH MICE, INCLUDING APT. 643 S./ -2S. | 643 W 62ND ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | SOUTH AND EAST EXTERIOR WALLS AT GRADE - SPALLING BRICKS AND ERODED MORTAR JOINTS. | 643 W 62ND ST | PERIODIC | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | FRONT INTERIOR STAIRS AT 643 S./ - HANDRAILS AND GUARDRAILS MISSING PICKETS; 1ST TO 3RD LOOSE AND SQUEAKY STAIRS. | 643 W 62ND ST | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | BASEMENT, INTERIOR STAIRWAY AND APARTMENTS AT 645 S./ - NO ENTRY, NO RESPONSE, UNABLE TO VERFY DETECTORS AND INTERIOR CONDITIONS. | 643 W 62ND ST | PERIODIC | FAILED | View |
EXPOSED WIRING | EXTENSION CORD RUNNING FROM BASEMENT UNDER CENTER PORCH TO APT. 1S. | 643 W 62ND ST | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | SOUTH AND CENTER PORCHES - LOOSE, SPLIT AND BROKEN TREADS. | 643 W 62ND ST | PERIODIC | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | 643 E. FRONT STAIRWAY GROUND FLOOR - FURNITURE BLOCKING THE EXIT | 643 W 62ND ST | PERIODIC | FAILED | View |
REPLACE DEFECTIVE TRAP | 643 S./ -2S, KITCHEN SINK - A PASTIC PIPE INSTALLED AS A P TRAP. | 643 W 62ND ST | PERIODIC | FAILED | View |
REMV OBSTR FROM DRAINAGE SYSTM | 643 S./ -2S, BATHTUB DRAIN - CLOGGED. | 643 W 62ND ST | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO MOST UNITS. | 643 W 62ND ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR | SOUTH BASEMENT EXTERIOR DOOR DRY ROTTED,NORTH DOOR RUSTED THRU. | 643 W 62ND ST | PERIODIC | FAILED | View |
PROVIDE DEADLOCK FOR ENTRANCE | 643-45 FRONT EXTERIOR DOORS; NO LOCKS. | 643 W 62ND ST | PERIODIC | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | SERVICE WALKS; BROKEN CONCRETE. | 643 W 62ND ST | PERIODIC | FAILED | View |
NO POSTED ADDRESS | POST ADDRESS ON ENTRANCE DOORS. | 643 W 62ND ST | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | POST OWNERSHIP ON BUILDING. | 643 W 62ND ST | PERIODIC | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | 643 INTERIOR STAIR HAND RAILS; LOOSE. | 643 W 62ND ST | PERIODIC | FAILED | View |
INSTALL DOOR VIEWING DEVICE | APARTMENT DOORS; NO PEEPHOLES. | 643 W 62ND ST | PERIODIC | FAILED | View |
DEBRIS, EXCESSIVE | PORCH AND BASEMENT AREA; JUNK AND DEBRIS. | 643 W 62ND ST | PERIODIC | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | WINDOW SCREENS; MISSING OR TORN. | 643 W 62ND ST | PERIODIC | FAILED | View |
MAINTAIN WINDOW | SOUTH WINDOW FRAME; METAL CAPPING MISSING. | 643 W 62ND ST | PERIODIC | FAILED | View |
REPAIR SKYLIGHT | 645 INTERIOR STAIR SKYLIGHT; LEAKS. | 643 W 62ND ST | PERIODIC | FAILED | View |
DWELLING CLEAN AND SANITARY | 645 INTERIOR STAIR WALLS; UNSANITARY CONDITION. | 643 W 62ND ST | PERIODIC | FAILED | View |
KEEP FIXTUR CLEAN AND SANITARY | 643 2-N,643 3-N AND 645 1-N BATHROOM TUBS; UNSANITARY CONDITION. | 643 W 62ND ST | PERIODIC | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | 645 INTERIOR STAIR 3RD FLR.CEILING; WATER DAMAGE. 645 1-N BATHROOM CEILING WATER DAMAGE AND HAS MILDEW. 643 2-N BATHROOM CEILING; BUCKLING. | 643 W 62ND ST | PERIODIC | FAILED | View |
INT WALL/CEILING CHIP PLASTER | 645 1-N BATHROOM HALLWAY CEILING; BROKEN PLASTER. | 643 W 62ND ST | PERIODIC | FAILED | View |
INSTALL SMOKE DETECTORS | 645 1-N NO SMOKE DETECTOR. | 643 W 62ND ST | PERIODIC | FAILED | View |
REPAIR FLOOR | 645 1-N LIVING ROOM FLOOR; WOOD STRIPS BROKEN. | 643 W 62ND ST | PERIODIC | FAILED | View |
PROV HOT WTR TO ALL FIXTURES | 645 1-N BATHROOM SINK LOW WATER PRESSURE. | 643 W 62ND ST | PERIODIC | FAILED | View |
INT WALL/CEILING PEELING PAINT | 645 1-N LIVING ROOM; PEELING PAINT. | 643 W 62ND ST | PERIODIC | FAILED | View |
PROVIDE HOT WATER TO FIXTURES | APARTMENT 2 SOUTH - KITCHEN SINK | 643 W 62ND ST | COMPLAINT | PASSED | View |
STOP LEAKING WATER | FROM APARTMENT 3-SOUTH TO CEILING AT 2-SOUTH. | 643 W 62ND ST | COMPLAINT | PASSED | View |
SOIL/WASTE,VENT PIPE MATRL | KITCHEN SINK P-TRAP | 643 W 62ND ST | COMPLAINT | PASSED | View |
SUPPORT FIXTURES | 643 2-N LIVING ROOM WALL LIGHT FIXTURE; HANGING OFF THE WALL. | 643 W 62ND ST | PERIODIC | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | INTERIOR OF BUILDING - NO RESPONSE, UNVERIIFED DETECTORS AND CONDITIONS. UNABLE TO VERIFY COMPLAINT ON SR# 183126589 FOR MOLD, ROACHES AND DOORBELLS NOT WORKING AT 2ND FLOOR APT. | 643 W 62ND ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | ALL ELEVATIONS / EXTERIOR WALLS - MASONRY FRACTURES. SOUTHEAST CORNER AT GRADE - MASONRY FRACTURES WITH SPALLING MASONRY AND LOOSE BRICK WORK. PERMIT REQUIRED FOR ALL MAONRY REPAIRS. | 643 W 62ND ST | PERIODIC | FAILED | View |
REPAIR WINDOW SILLS | WEST ELEVATION AT 645 / 3RD FLOOR SILLS - WASHED OUT MORTAR. | 643 W 62ND ST | PERIODIC | FAILED | View |
REPAIR COPING | WEST ELEVATION / COPING - MISSING. | 643 W 62ND ST | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | EAST ELEVATION / REAR 3 STORY PORCH AT 643 / 1ST FLOOR GUARD RAIL - ROTTING TOP RAIL. | 643 W 62ND ST | PERIODIC | FAILED | View |
RAT PROOF OPENINGS | NORTHWEST ELEVATION / DOORWAY THAT HAS BEEN BOARDED WITH PLYWOOD HAS A GAP AT THE BOTTOM UP TO 3 INCHES. | 643 W 62ND ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | SOUTHEAST CORNER AT GRADE - MASONRY FRACTURES WITH SPALLING MASONRY AND LOOSE BRICK WORK. PERMIT REQUIRED FOR ALL MAONRY REPAIRS. | 643 W 62ND ST | PERIODIC | FAILED | View |
RAT PROOF OPENINGS | SOUTH AND EAST BASEMENT DOORS - DO NOT LOCK. (ALLOWING RODENTS IN TO BUILDING). | 643 W 62ND ST | PERIODIC | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | SOUTH, WEST AND NORTH ELEVATIONS - WINDOW SCREENS ARE MISSING OR RIPPED. | 643 W 62ND ST | PERIODIC | FAILED | View |
PARAPET | WEST PARAPET - WASHED OUT MORTAR. | 643 W 62ND ST | PERIODIC | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | INTERIOR OF MOST APTS. - NO ENTRY, UNVERIIFED DETECTORS AND INTERIOR CONDITIONS. | 643 W 62ND ST | PERIODIC | FAILED | View |
MAINTAIN WINDOW | SOUTH ELEVATION 2ND FLOOR WINDOW - MISSING ALUMINUM CAPPING. | 643 W 62ND ST | PERIODIC | FAILED | View |
STOP STORING GARBAGE | 945 AT CENTER PORCH / 2ND FLOOR - STORING GARBAGE. 3RD FLOOR - STORING DISGARDED CONSTRUCTION MATERIALS | 643 W 62ND ST | PERIODIC | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | 943 / FRONT INTERIOR STAIRWAY / HANDRAIL AND GUARDRAIL - MISSING BALLUSTERS. | 643 W 62ND ST | PERIODIC | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | 943 AND 945 / FRONT INTERIIOR STAIRWAYS / SMOKE DETECTORS - OUT OF DATE ( YELLOWING ). | 643 W 62ND ST | PERIODIC | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | 943 AND 945 / FRONT APT. DOORS - BURGLAR GATES INSTALLED. 945 AT CENTER REAR PORCH / PORCH STAIRS AT 2ND AND 3RD FLOORS - BLOCKED WITH PLYWOOD. | 643 W 62ND ST | PERIODIC | FAILED | View |
SAFE WORKING CONDITIONS | 13 UNIT BUILDING /SAFE WORK CONDITIONS - BOILER BROKEN . | 643 W 62ND ST | COMPLAINT | FAILED | View |
UNAPPROVED HEATING DEVICE | APT 643/ 3RD FLN /UNAPPROVE HEATING DEVICE- SPACE HEATERAPT 643 2ND FL S / STOVE USED FOR HEAT .PER SECTION CODE . (14X-7-705.4 | 643 W 62ND ST | COMPLAINT | FAILED | View |
WINDOW REPAIR FOR AIR SEEPAGE | 643/APT 3N / AIR SEE PAGE - FRONT ROOM AND KITCHEN PER SECTION CODE (14X-3-303.13 AND 14X-12-1202.4.3.3 | 643 W 62ND ST | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | BOILER RM / CARBON MONOXIDE - MISSING .3RD FL APT /643 /CARBON MONOXIDE - MISSING PER SECTION CODE . (14X-5-504.9, 14B-9-915.1.1, 14B-9-915.2 , AND 14R-11-1105 | 643 W 62ND ST | COMPLAINT | FAILED | View |
HEAT UNIT ADEQUATELY | 643 APT 2 /TEMP AT 119 PM BEDROOM 57 AND KITCHEN 56 DEGREES . PER SECTION CODE . (14X-8-802.2, 14X-8-802.2.1AND 14X-8-802.2.2) BHA CODES | 643 W 62ND ST | COMPLAINT | FAILED | View |
EXPOSED WIRING | APT 2S/ AND BASMENT APT / EXPOSED WIRES- BASEMENT THROUGH OUT. | 643 W 62ND ST | COMPLAINT | FAILED | View |
ROACHES | 3RD FL APT / ROACHES - IN KITCHEN . | 643 W 62ND ST | COMPLAINT | FAILED | View |
REPAIR ROOF | APT 3/ ROOF - LEAKING IN KITCHEN . | 643 W 62ND ST | COMPLAINT | FAILED | View |
MICE/RODENTS | 3RD FL AP / MICE - DROPING IN KITCHEN . | 643 W 62ND ST | COMPLAINT | FAILED | View |
DWELLING CLEAN AND SANITARY | BASEMENT APT / NOT SANITARY - WATER STAINS WALL AND CEILING THROUGH OUT. DEMO DEBRIS ON THE FLOOR .DEMO PERMIT REQUIRED FOR BASEMENT DEMO . | 643 W 62ND ST | COMPLAINT | FAILED | View |
FLOOR, KIT & BATH NON-ABSORB | 3RD FL APT / BATHROOM- WALLS AND CEILING WATER DAMAGE. | 643 W 62ND ST | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | 3RDFL APT / KITCHEN CEILING - LARGE SECTION OF PLASTER LOOSE. | 643 W 62ND ST | COMPLAINT | FAILED | View |
REPAIR LINTELS | WEST ELEVATION AT 645 / 3RD FLOOR WINDOW LINTEL - RUSTED DETERIORATED. PLANS AND PERMIT REQUIRED TO REPAIR LINTEL. | 643 W 62ND ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | EAST ELEVATION AT 643 BASEMENT TO GRADE / STAIRS - MISSING HANDRAIL. | 643 W 62ND ST | PERIODIC | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | NORTH ELEVATION / 1ST FLOOR WINDOW - BROKEN. | 643 W 62ND ST | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | REGISTER BUILDING FOR 1990 THRU 2013. | 643 W 62ND ST | PERIODIC | FAILED | View |
SELF-CLOSE CLASS B FIRE DOOR | FRONT EXTERIOR DOORS; NO SELF-CLOSING DEVICE. | 643 W 62ND ST | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING / OWNER'S ID SIGN - MISSING | 643 W 62ND ST | PERIODIC | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | 643 E. FRONT STAIRWAY GROUND FLOOR - SHOPPING CART AND BICYCLE BLOCKING THE EXIT | 643 W 62ND ST | PERIODIC | FAILED | View |
DEBRIS, EXCESSIVE | (1) FRONT ENTRY STAIRWAYS ALL FLOORS - TRASH OBSERVED THROUGHOUT(2) REAR OPEN WOOD STAIRS - TRASH OVSERVED THROUGHOUT | 643 W 62ND ST | PERIODIC | FAILED | View |
CORRODED CONDUIT & EQUIP | CORRODID CONDUIT IN FRONT OF BLDG | 643 W 62ND ST | COMPLAINT | FAILED | View |
SECURE RACEWAY | STRAP AND SECURE RACEWAY IN FRONT OF BLDG | 643 W 62ND ST | COMPLAINT | FAILED | View |
REPLACE************** | REPLACE OPEN PORCH FIXTURES WITH RATED OUTDOOR FIXTURES | 643 W 62ND ST | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | 3RD FL APT / CARBON MONOXIDE - MISSING. | 643 W 62ND ST | COMPLAINT | FAILED | View |
1HR FLR OVER BSMT, 1 OR 2 DU | BASEMENT APT / CEILING - HOLES. | 643 W 62ND ST | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | BASEMENT APT / WALLS AND CEILING - WATER DAMAGE THROUGH OUT . | 643 W 62ND ST | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | BASEMENT AND 2ND FL / PERMIT REQUIRED -FOR NEW COPPER PIPES. BASEMENT APT / PERMIT REQUIRED - FOR NEW FURNACE AND PIPES. BASEMENT/ PERMIT REQUIRED - FOR NEW BOILER FOR 13 UNIT BUILDING THAT IS BROKEN AND GOING TO BE REPLACE. | 643 W 62ND ST | COMPLAINT | FAILED | View |
OPEN | 643 W 62ND ST | PERMIT | FAILED | View |