The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR EXTERIOR DOOR FRAME | SOUTH ENTRY DOOR JAMB IS BROKEN/DAMAGED. | 252 W 109TH ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | NORTH WOOD PORCH HAS UNDERSIZED GUARDRAILS. | 252 W 109TH ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | 1ST FLOOR/BASEMENT MISSING SMOKE DETECTORS. | 252 W 109TH ST | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | 1ST FLOOR/BASEMENT MISSING CARBON MONOXIDE DETECTORS. | 252 W 109TH ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | SOUTH WOOD STAIRS HAS UNDERSIZED GUARDRAILS, INCORRECT PICKET SPACING, LOOSE HANDRAILS, 4X4 SUPPORT COLUMNS RESTING ON BLOCKS. | 252 W 109TH ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | BASEMENT ORIGINAL CONSTRUCTION WAS FOR STORAGE AND TO CONTAIN THE HEATING UNIT. CURRENT CONSTRUCTION HAS WOOD FRAMED NON-LOAD BEARING PARTITION WALLS FORMING TWO BEDROOMS, BATH (13-32-010, 13-196-070, 13-196-650 THRU 13-196-740). ALL WORK CONSTRUCTED WITHOUT PLANS/PERMITS. | 252 W 109TH ST | COMPLAINT | FAILED | View |
VENT SYSTEM TO PRVNT BACK PRES | NO VENT ON LAUNDRY WASTE IN BASEMENT EAST ELEVATION. | 252 W 109TH ST | COMPLAINT | FAILED | View |
INSTALL FIXTURES PROPERLY | LAUNDRY WASTE FOR WASH MACHINE NOT TO CODE BASEMENT EAST ELEVATION. | 252 W 109TH ST | COMPLAINT | FAILED | View |
LICENSED BONDED PLMBG CONTRCTR | OBTAIN A LICENSED PLUMBER TO DO PLUMBING WORK. | 252 W 109TH ST | COMPLAINT | FAILED | View |
CEILING HEIGHT - 7' - BASEMENT | CEILING HEIGHT UNDER 7 FT. | 252 W 109TH ST | COMPLAINT | FAILED | View |
CONTRARY TO ORIGINAL PLAN | RETURN BASEMENT TO ORIGINAL CONSTRUCTION. REMOVE ALL NON-LOAD BEARING PARTITION WALLS FORMING TWO BEDROOMS AND A BATH. | 252 W 109TH ST | COMPLAINT | FAILED | View |
PROPER MATRL WATER SUPPLY PIPE | REMOVE FLEXIBLE SUPPLIES TO LAVATORY, TOILET AND KITCHEN SINK 1ST FLOOR; LAVATORY, TOILET BASEMENT. | 252 W 109TH ST | COMPLAINT | FAILED | View |
VENT SYSTEM TO PRVNT BACK PRES | NO VENT ON KITCHEN WASTE. | 252 W 109TH ST | COMPLAINT | FAILED | View |
SUBMIT PLANS FOR PLUMBING PRMT | NO PERMIT FOR LAVATORY, TOILET AND SHOWER BASEMENT. | 252 W 109TH ST | COMPLAINT | FAILED | View |
REMV OBSTR FROM DRAINAGE SYSTM | LAVATORY IN BASEMENT BATHROOM DOESN'T DRAIN. | 252 W 109TH ST | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | REPLACE DEFECTIVE LIGHT FIXTURES MISSING GLOBES, 1ST FLOOR AND BASEMENT. | 252 W 109TH ST | COMPLAINT | FAILED | View |
(18-27-210.8) INSTALL GFCI'S TO WET LOCATIONS SPECIFICALLY BATHROOMS AND AS NEEDED. | 252 W 109TH ST | COMPLAINT | FAILED | View | |
INSTALL COVERS | INSTALL COVERS TO OPEN DEVICES AND BOXES. | 252 W 109TH ST | COMPLAINT | FAILED | View |
INSTALL ILLUMINATION | INSTALL ILLUMINATION TO ALL EXTERIOR ENTRY DOORS. | 252 W 109TH ST | COMPLAINT | FAILED | View |
(13-12-360) PROVIDE PERMIT TO CORRECT VIOLATIONS. | 252 W 109TH ST | COMPLAINT | FAILED | View | |
OBTN PERMIT FOR PLUMBING WORK | PERMIT FOR VIOLATIONS. | 252 W 109TH ST | COMPLAINT | FAILED | View |
PROVIDE | HOT WATER TANK HAS A BACK PITCHED FLUE PIPE CAUSING A DANGEROUS AND HAZARDOUS CONDITION. (18-28-803.10.5) | 252 W 109TH ST | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | SERVICE WALK HAS BROKEN CONCRETE CAUSING A TRIP HAZARD. | 252 W 109TH ST | COMPLAINT | FAILED | View |