Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR EXTERIOR WALL | EXTERIOR WALLS- WORN; MISSING SECTIONS OF SIDING. | 1248 S TRIPP AVE | COMPLAINT | FAILED | View |
REPAIR WINDOW SILLS | WINDOW SILLS- WORN; ROTTED. | 1248 S TRIPP AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | ENCLOSED PORCH (WORK IN PROGRESS; WITHOUT PLANS / PERMIT)- COLUMNS AND BEAMS FROM (B) TO (1) WERE REPLACED. COLUMNS ARE SET ON A NEW SECTION OF RETAINING WALL; FOUNDATION STATUS IS UNKNOWN. OPEN HOLE IS MISSING FOOTING. OPEN BEAM POCKETS; NO VISIBLE CONNECTORS / STRAPS. BEAMS ARE ONLY RESTED ON TOP OF THE COLUMNS. COLUMN IS PULLING FROM THE BEAM SUPPORTING THE SECOND FLOOR LANDING. UNDERSIZED 2X6 JOISTS FOR A 12 FEET SPAN. IMPROPER CONNECTIONS- MOST MEMBERS ARE ONLY TOE NAILED TOGETHER. PLANS AND PERMIT REQUIRED FOR REPAIRS. | 1248 S TRIPP AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | WINDOW PANES- BROKEN; MISSING; BOARDED UP. | 1248 S TRIPP AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW SASH | WINDOW SASHES- WORN; MISSING. | 1248 S TRIPP AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | WINDOW FRAMES- WORN. | 1248 S TRIPP AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | OWNER'S I.D. SIGN IS NOT POSTED. | 1248 S TRIPP AVE | COMPLAINT | FAILED | View |
REPAIR DOWNSPOUT | SOUTHWEST CORNER AT GRADE - DOWNSPOUT - MISSING 4FT SECTION. | 1248 S TRIPP AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING NO RESPONSE,UNVERIFIED COMPLAINT OF CHIPPING PAINT,WINDOW SASH AND SMOKE ALARM TOO HIGH.UNVERIFIED DETECTORS AND CONDITIONS. | 1248 S TRIPP AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | SOUTH ELEVATION - MASONRY WALL NEAR TOP - SPALLING BRICKS AND WASHED OUT MORTAR. | 1248 S TRIPP AVE | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | EAST ELEVATION - BASEMENT GUARDRAILS - SPACED 10" APART. | 1248 S TRIPP AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | EAST ELEVATION - RAILINGS SPACED 12" APART. | 1248 S TRIPP AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | 312-743-0413 MON -FRI | 1248 S TRIPP AVE | COMPLAINT | FAILED | View |
TEST ALTERED SYSTEM | SR# 11-04234018 | 1248 S TRIPP AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | EAST ELEVATION - 2ND FLOOR WINDOW PANE - BROKEN. | 1248 S TRIPP AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | GAINED ENTRY TO 2ND FLOOR BUT NOT TO 1ST FLOOR,BASEMENT AND ATTIC TO VERIFY OCCUPANCY,DETECTORS AND CONDITIONS. | 1248 S TRIPP AVE | COMPLAINT | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | 2ND FLOOR FRONT ROOM - SMOKE DETECTOR - OUT OF SERVICE. | 1248 S TRIPP AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | 2ND FLOOR KITCHEN AND FRONT HALLWAY - SMOKE DETECTORS - MISSING. | 1248 S TRIPP AVE | COMPLAINT | FAILED | View |
INSTALL EXTRA SMOKE DETECTORS | 2ND MISSING SMOKE DETECTOR. | 1248 S TRIPP AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | 2ND MISSING CARBON MONOXIDE CARBON. | 1248 S TRIPP AVE | COMPLAINT | FAILED | View |
EXPOSED WIRING | ELECTRIC PANELING AT BASEMENT MISSING COVER AND EXPOSED WIRING. | 1248 S TRIPP AVE | COMPLAINT | FAILED | View |
INSTALL EXTRA SMOKE DETECTORS | 2ND MISSING SMOKE DETECTOR. | 1248 S TRIPP AVE | COMPLAINT | CLOSED | View |
CARB MONOX DETECT IN RESID | 2ND MISSING CARBON MONOXIDE CARBON. | 1248 S TRIPP AVE | COMPLAINT | CLOSED | View |
EXPOSED WIRING | ELECTRIC PANELING AT BASEMENT MISSING COVER AND EXPOSED WIRING. | 1248 S TRIPP AVE | COMPLAINT | CLOSED | View |
EXPOSED WIRING | OPEN METER SOCKETS DANGEROUS AND HAZARDOUS REAR EXTERIOR FLEX WITH WIRES FRONT BASEMENT EXTERIOR DOOR | 1248 S TRIPP AVE | COMPLAINT | FAILED | View |
SECURE SEC | UNSUPPORTED UNTERMINATED DANGEROUS AND HAZARDOUS REAR EXTERIOR SERVICE ENTRANCE CABLE | 1248 S TRIPP AVE | COMPLAINT | FAILED | View |
TENANT ACCESS TO SERVICE | NO TENANT ACCESS TO SERVICE BASEMENT | 1248 S TRIPP AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNER'S ID SIGN POST. | 1248 S TRIPP AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLAN AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT OR RESTORE THE BUILDING TO THE ORIGINAL STATE. | 1248 S TRIPP AVE | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | REMOVE ALL PARTITIONS AND FIXTURE (INCLUDING PLUMBING AND ELECTRIC) INSTALLED IN THE BASEMENT WITHOUT A PERMIT. | 1248 S TRIPP AVE | COMPLAINT | FAILED | View |
CIRCUIT ONE UNIT ONLY | INSTALL PUBLIC METER SEPARATED TENANT CIRCUITRY SERVICE | 1248 S TRIPP AVE | COMPLAINT | FAILED | View |
STRAP SERVICE CONDUIT | STRAP SERVICE ENTRANCE CABLE ON REAR OF BUILDING | 1248 S TRIPP AVE | COMPLAINT | PASSED | View |
NO PERMIT WIRING | PROVIDE PERMIT FOR NEW 4 METER SERVICE INSTALLED WITHOUT | 1248 S TRIPP AVE | COMPLAINT | PASSED | View |
SEE INSPECTOR COMMENTS | PROVIDE FULL INTERIOR INSPECTIONS18-27-110.3 | 1248 S TRIPP AVE | COMPLAINT | PASSED | View |
POST OWNER/MANAGERS NAME/# | MANAGEMENT SIGN - MISSING | 1248 S TRIPP AVE | COMPLAINT | CLOSED | View |
REPUTTY WINDOW PANES | 2ND FLOOR - WINDOW TRIM - PAINT PEELING | 1248 S TRIPP AVE | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR WALL | EXTERIOR WALL - WASHED OUT MORTAR NEAR GRADE. | 1248 S TRIPP AVE | COMPLAINT | CLOSED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | 1ST FLOOR APT | 1248 S TRIPP AVE | COMPLAINT | FAILED | View |
DEFECTIVE METER EQUIPMENT | 2 - MISSING METER | 1248 S TRIPP AVE | COMPLAINT | PASSED | View |