Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-22 @ 2:16 AM
PIN: 13353050240000
Property Address: 1940 N MONTICELLO AVE
City - Zip: CHICAGO - 60647
2023 Property Class: 211
2023 Township: 71 - Jefferson
2023 Neighborhood: 71180
2023 Tax District: 71163
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 20 Violations
Violation Inspector Comments Address Category Status View
REPAIR PORCH SYSTEM FRONT PORCH - 2X8 JOISTS SPANNED 10 FEET 6 INCHES BUTTING 2X8 SINGLE BEAM, MISSING BOLTS ON RIM JOISTS TO 6X6 COLUMN, MISSING BOLTS ON TOP OF STRINGER RAILS ARE ONLY 36" HIGH. SUBMIT PLANS AND OBTAIN PERMIT FOR REPAIRS. REAR PORCH - FOUNDATION STATUS UNKNOWN, LANDINGS ARE SEVERELY OUT OF LEVEL, MISSING BOLTS ON TOP OF STRINGERS, MISSING BOLTS ON STRINGERS ALONG BUILDING, MISSING BOLTS ON 4X4 POST WHICH MAKE UP RAIL SYSTEM. ENCLOSED PORCH, SUBMIT PLANS AND OBTAIN PERMIT TO REPLACE REAR PORCH. 1940 N MONTICELLO AVE COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR SUBMIT PLANS AND OBTAIN PERMIT FOR BUILDING OF NEW BALCONY, 4X6 COLUMN BEARING DOWN ON CONCRETE SLAB. 2X8 LEDGER BEAM NOT BOLTED ONLY SCREWED. 1940 N MONTICELLO AVE COMPLAINT FAILED View
PROVIDE GUARD RAIL 42 IN HIGH SOUTH ELEVATION - MISSING GUARDRAIL AT GRADE LEVEL. 1940 N MONTICELLO AVE COMPLAINT FAILED View
REPAIR EXTERIOR STAIR SOUTH ELEVATION - MISSING HANDRAIL GRADE TO BASEMENT. 1940 N MONTICELLO AVE COMPLAINT FAILED View
PERMIT REQUIRED - CONTRACTOR OBTAIN PERMIT FOR INSTALLATION OF NEW FRONT SIDE ENTRY DOOR. 1940 N MONTICELLO AVE COMPLAINT FAILED View
REPAIR INTERIOR STAIR SYSTEM FRONT INTERIOR STAIRS - BROKEN BRACKET ON HANDRAIL 1ST TO 2ND. 1940 N MONTICELLO AVE COMPLAINT FAILED View
REPAIR EXTERIOR DOOR HARDWARE 2ND FLOOR - FRONT ENTRY DOOR - MISSING DOOR KNOB. 1940 N MONTICELLO AVE COMPLAINT FAILED View
INSTALL DOOR VIEWING DEVICE 2ND FLOOR/ 1ST FLOOR - MISSING VIEWING DEVICE. 1940 N MONTICELLO AVE COMPLAINT FAILED View
INT WALL/CEILING CHIP PLASTER 2ND FLOOR - FRONT CLOSET - LARGE HOLES. 1940 N MONTICELLO AVE COMPLAINT FAILED View
DEBRIS, EXCESSIVE 1ST FLOOR REAR ENCLOSED PORCH STORAGE OF WASHER AND DRYER. 1940 N MONTICELLO AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS REAR ENCLOSED PORCH - MISSING SMOKE DETECTOR. 1940 N MONTICELLO AVE COMPLAINT FAILED View
PERMIT REQUIRED - CONTRACTOR REAR BASEMENT - OBTAIN PERMIT FOR PLUMBING WORK, SEE NEW COPPER PIPE, PVC. NEW DRYWALL. 1940 N MONTICELLO AVE COMPLAINT FAILED View
REMV OBSTR FROM DRAINAGE SYSTM 2ND FLOOR - BATHROOM CLOGGED BATHROOM SINK. 1940 N MONTICELLO AVE COMPLAINT FAILED View
RESET LOOSE FIXTURE 2ND FLOOR - BATHROOM - LOOSE TOILET. 1940 N MONTICELLO AVE COMPLAINT FAILED View
RATS ATTIC FLOOR - RAT DROPPINGS. 1940 N MONTICELLO AVE COMPLAINT FAILED View
NO POSTED ADDRESS NO ADDRESS POSTED. 1940 N MONTICELLO AVE COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# NO OWNER I.D. SIGN POSTED. 1940 N MONTICELLO AVE COMPLAINT FAILED View
NO KEY TO USE EXIT DOOR FRONT GATES DOUBLE KEYED LOCK. 1940 N MONTICELLO AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING- NO RESPONSE, UNVERIFIED DETECTORS. 1ST FLOOR APARTMENT- NO ENTRY, UNVERIFIED COMPLAINT OF: CLOGGED BATHROOM DRAIN, AND OUT OF SERVICE AIR CONDITIONER. 1940 N MONTICELLO AVE COMPLAINT FAILED View
REPAIR SCREENS FRONT 2ND FLOOR - WINDOW SCREENS TORN. 1940 N MONTICELLO AVE COMPLAINT FAILED View