Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REMV OBSTR FROM DRAINAGE SYSTM | BASEMENT BACK-UP FROM FLOOR DRAIN (18-29-102) | 1542 N LEAMINGTON AVE | COMPLAINT | FAILED | View |
ENGAG LIC & BOND PLMBNG CNTRC | LICENSED AND BONDED PLBG CONT-(18-29-106) | 1542 N LEAMINGTON AVE | COMPLAINT | FAILED | View |
STOP SMOKE, NOXIOUS ODORS | BASEMENT 1ST, AND 2ND FLOORS SEWAGE ODORS. | 1542 N LEAMINGTON AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | SR#06-01941596 REAR PORCH FOUNDATION STATUS UNKNOWN, COLUMNS ARE ONLY 4X4, OUT OF PLUMB (BOWING, TWISTING). LEDGER BEAMS (ROTTING) AND STRINGERS ATTACHED TO BUILDINGS EXTERIOR WALLS WITH NAILS ONLY. UNDERSIZED 2X6 FLOOR JOISTS AT 2ND FLOOR OVER 9 FEET SPANS. FLOOR JOISTS ARE TOE-NAILED TO HEADER JOIST THRU-OUT STRINGERS ARE INADEQUATELY SUPPORTED AT COLUMS. RAILING SECTIONS ARE ONLY 30 INCHES HIGH. TREADS ARE ONLY 8 INCHES WIDE. OBTAIN PLANS AND PERMITS TO MAKE ALL NECESSARY REPAIRS OR REPLACE REAR PORCH. | 1542 N LEAMINGTON AVE | COMPLAINT | FAILED | View |
PROVIDE | REAR GUTTERS LEAKING / RUSTED SEC 18-29-1101.2.1 | 1542 N LEAMINGTON AVE | COMPLAINT | FAILED | View |
CUT OR REMOVE HIGH WEEDS | REAR YARD HIGH WEEDS | 1542 N LEAMINGTON AVE | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | REMOVE ALL PARTITIONS AND FIXTURES (INCLUDING PLUMBING AND ELECTRIC) INSTALLED IN THE BASEMENT WITHOUT A PERMIT. | 1542 N LEAMINGTON AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT OR RESTORE THE BUILDING TO THE ORIGINAL STATE. | 1542 N LEAMINGTON AVE | COMPLAINT | FAILED | View |
REMOVE STAGNANT WATER BSMT | BASEMENT FLOOR THRU-OUT APARTMENT AND HEATING / STORAGE ROOM - STAGNANT AND SEWAGE WATER | 1542 N LEAMINGTON AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | 1ST FLOOR REAR BEDROOM HOLES IN WALLS / BATHROOM TILES MISSING FROM WALLS | 1542 N LEAMINGTON AVE | COMPLAINT | FAILED | View |
WINDOW REPAIR FOR AIR SEEPAGE | 1ST FLOOR REAR WINDOWS DRAFTY (FRAMES) | 1542 N LEAMINGTON AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | MISSING OWNER'S I.D. SIGN (NOT POSTED) | 1542 N LEAMINGTON AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH: 4X4 COLUMNS UNDERSIZED FOR LENGTH OVER 12', 2X6 JOIST AT LAND ARE UNDERSIZED, STRINGER AT BUILDING SIDE NOT BOLTED, LEDGER AT 1ST FLOOR NOT BOLTED TO BUILDING, RAILS ONLY 39" HIGH; OBTAIN PERMIT | 1542 N LEAMINGTON AVE | COMPLAINT | FAILED | View |
INT WALL/CEILING PEELING PAINT | BATHROOM WALL TILE MISSING, REAR BEDROOM, 1ST FLOOR-CEILING HAS WATER DAMAGE | 1542 N LEAMINGTON AVE | COMPLAINT | FAILED | View |
WINDOW REPAIR FOR AIR SEEPAGE | WINDOWS ARE DRAFTY | 1542 N LEAMINGTON AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | WINDOW BROKEN AT SIDE STAIRWELL | 1542 N LEAMINGTON AVE | COMPLAINT | FAILED | View |
RELOCATE SMOKE DETECTOR | SMOKE DETECTOR: RELOCATE TO TOP OF STAIRWELL | 1542 N LEAMINGTON AVE | COMPLAINT | FAILED | View |
REPAIR OR REPLACE | GUTTER MISSING SECTION OF DOWNPOUT AT SOUTHEAST CORNER (SEC. 18-29-1101.2.1) | 1542 N LEAMINGTON AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | HOLE IN WALL AT REAR BY FOUNDATION WALL & HALF DOOR | 1542 N LEAMINGTON AVE | COMPLAINT | FAILED | View |
PRV CAST IRON COVER FOR BASIN | DRAIN COVER MISSING AT REAR BASEMENT BY DOOR | 1542 N LEAMINGTON AVE | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | GUARDRAIL MISSING AT REAR DROP OFF TO BASEMENT BY DOOR | 1542 N LEAMINGTON AVE | COMPLAINT | FAILED | View |
REPAIR WINDOW SILLS | OPEN MORTAR JOINT AT SILL, 1ST FLOOR, REAR | 1542 N LEAMINGTON AVE | COMPLAINT | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | DEFECTIVE SMOKE DETECTORS 1ST FLOOR APARTMENT, 2ND FLOOR APARTMENT, SOUTH ENTRANCE STAIRWAY AY 2ND FLOOR (TOP). | 1542 N LEAMINGTON AVE | COMPLAINT | FAILED | View |
REPAIR EAVES | EAVES AT SOUTHWEST CORNER, ROTTED-HAS A LARGE HOLE, GUTTER RUSTED | 1542 N LEAMINGTON AVE | COMPLAINT | FAILED | View |