Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-24 @ 12:26 PM
PIN: 20182000070000
Property Address: 1935 W GARFIELD BLVD
City - Zip: CHICAGO - 60636
2023 Property Class: 211
2023 Township: 72 - Lake
2023 Neighborhood: 72120
2023 Tax District: 72001
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 35 Violations
Violation Inspector Comments Address Category Status View
PARAPET EAST PARAPET: DISPLACED BRICKWORK 1935 W GARFIELD BLVD COMPLAINT FAILED View
CHIMNEY EAST CHIMNEY: OPEN MORTAR JOINTS-DISPLACED BRICKWORK 1935 W GARFIELD BLVD COMPLAINT FAILED View
REPAIR / REBUILD SHED BRICK GARAGE: PARAPET WALL OUT OF PLUMB-SEVERE (15 FEET) BACKWARD TILT-UNSAFE CONDITION; BRICKWORK ABOVE OVERHEAD DOOR STRUCTURAL LINTEL DISPLACED, SHIFTED-UNSAFE CONDITION AT ALLEY-SEVERELY ERODED MORTAR AND FAILED MORTAR PATCH JOB 1935 W GARFIELD BLVD COMPLAINT FAILED View
PERMIT REQUIRED - CONTRACTOR FOR ALL MASONRY REPAIRS 1935 W GARFIELD BLVD COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# NO OWNER'S ID NOT OWNER OCCUPIED. 1935 W GARFIELD BLVD COMPLAINT FAILED View
CARB MONOX DETECT IN RESID MISSING CARBON MONOXIDE DETECTOR 1ST FLR. 1935 W GARFIELD BLVD COMPLAINT FAILED View
REPAIR BALCONY NORTH 2STORY BRICK BALCONY BULGING, BRICKS ON COLUMNS, OPEN MORTAR JOINTS ON 2ND FLR LINTEL, LIMESTONE MOVEMENT ON 2ND FLR GUARDRAILS. MASON PERMIT. 1935 W GARFIELD BLVD COMPLAINT FAILED View
REPAIR / REBUILD SHED REAR BRICK GARAGE SOME SPALLING ON CEMENT COATING, OUTWARD BULGING ON WEST WALL, MISSING GUTTER. 1935 W GARFIELD BLVD COMPLAINT FAILED View
REPAIR LINTELS NORTH ELEVATION BALCONY LINTELS SEVERLY RUSTING AND SAGGING, EAST ELEVATION LINTELS SAGGING AND RUSTING.PERMIT REQUIRED. 1935 W GARFIELD BLVD COMPLAINT FAILED View
INSTALL SMOKE DETECTORS SMOKE DETECTORS NOT WORKING IN FRONT STAIRWAY AND REAR STAIRWAY. 1935 W GARFIELD BLVD COMPLAINT FAILED View
REPAIR GUTTER NORTHWEST ELEVATION /DOWNSPOUTS - RUSTED, WITH LARGE HOLES; 1935 W GARFIELD BLVD COMPLAINT FAILED View
CHIMNEY CAPPING WEST ELEVATION /CHIMNEY CAPPING - WASHED OUT MORTAR; 1935 W GARFIELD BLVD COMPLAINT FAILED View
WORK NOT ALLOWED REMOVE ALL PARTITIONS AND FIXTURES [INCLUDING PLUMBING AND ELECTRIC] INSTALLED IN THE BASEMENT WITHOUT PERMIT. 1935 W GARFIELD BLVD COMPLAINT FAILED View
REPAIR BALCONY 2 STORY FRONT BALCONY: BRICKWORK ABOVE STRUCTURAL LINTELS IS SEVERELY SHIFTED, DISPLACED 1935 W GARFIELD BLVD COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION 1ST. AND 2ND. FL. APTS. - ENTRY REFUSED;INTERIOR OF BUILDING ¿ NO RESPONSE; UNABLE TO VERIFY DETECTORS, CONDITIONS AND OCCUPANCY;UNABLE TO INSPECT INTERIOR STAIRWAY; UNABLE TO INSPECT REAR ENCLOSED PORCH; 1935 W GARFIELD BLVD COMPLAINT FAILED View
REPAIR LINTELS FRONT, EAST, WEST ELEVATION /METAL BALCONY LINTELS/"I" BEAMS - RUSTED, BENT, SAGGING, WITH GAPS ABOVE IT;EAST ELEVATION /METAL WINDOW LINTELS - RUSTED, BENT, SAGGING, WITH GAPS ABOVE IT;MOST WINDOW LINTELS CAPPED WITH METAL, UNABLE TO INSPECT CONDITIONS; NOTE: REMOVE METAL WRAP COVERING LINTELS, WRAP IS CAUSING PREMATURE FAILURE; PLANS AND PERMIT REQUIRED; 1935 W GARFIELD BLVD COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# BUILDING /OWNER¿S I.D. SIGN ¿ [ADDRESS] MISSING; 1935 W GARFIELD BLVD COMPLAINT FAILED View
PROVIDE GUARD RAIL 42 IN HIGH FRONT ELEVATION [GRADE TO BASEMENT] /METAL GUARD RAIL AND HAND RAIL SECTION UNDERSIZED - RUSTED, LOOSE AND PULLING; 1935 W GARFIELD BLVD COMPLAINT FAILED View
REPAIR COPING EAST ELEVATION /COPING - WASHED OUT MORTAR; WEST ELEVATION /COPING - MISSING; 1935 W GARFIELD BLVD COMPLAINT FAILED View
REPAIR CORNICE EAST ELEVATION /CORNICE - WASHED OUT MORTAR; 1935 W GARFIELD BLVD COMPLAINT FAILED View
REPAIR WINDOW SILLS EAST ELEVATION /STONE WINDOW SILLS - WASHED OUT MORTAR; 1935 W GARFIELD BLVD COMPLAINT FAILED View
REPAIR EXTERIOR WALL FRONT ELEVATION /EXTERIOR [WING] WALL - WASHED OUT MORTAR; 1935 W GARFIELD BLVD COMPLAINT FAILED View
PARAPET WEST ELEVATION /PARAPET WALL [AT FRONT] - SPALLING BRICK, WITH WASHED OUT MORTAR; 1935 W GARFIELD BLVD COMPLAINT FAILED View
DEBRIS, EXCESSIVE REAR ELEVATION [AT WEST] /JUNK, DEBRIS - EXCESSIVE BROKEN UP CONCRETE; 1935 W GARFIELD BLVD COMPLAINT FAILED View
REPAIR EXTERIOR DOOR FRONT ELEVATION /EXTERIOR DOOR [1ST. FL.] - OFF HINGES, LOOSE PLEXIGLAS;FRONT ELEVATION /EXTERIOR DOOR [BASEMENT] - OFF HINGES; 1935 W GARFIELD BLVD COMPLAINT FAILED View
REPAIR EXTERIOR DOOR HARDWARE FRONT ELEVATION /EXTERIOR DOOR HARDWARE LOOSE; CLOSER - MISISING; 1935 W GARFIELD BLVD COMPLAINT FAILED View
REPAIR/REBUILD GARAGE OR SHED GARAGE /OVER HEAD DOOR - METAL LINTEL/"I" BEAM - RUSTED, BENT, SAGGING, WITH HOLES ABOVE IT; WEST ELEVATION /EXTERIOR WALL - OUT OF PLUMB - LEANING OUTWARD; PARGED, SPALLING BRICK, WITH WASHED OUT MORTAR;SOUTH ELEVATION /EXTERIOR WALL - LOOSE, PARGED, SPALLING BRICK, WITH WASHED OUT MORTAR;PLANS AND PERMIT REQUIRED; 1935 W GARFIELD BLVD COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS EAST ELEVATION /BASEMENT WINDOWS - BOARDED UP; 1935 W GARFIELD BLVD COMPLAINT FAILED View
INSTALL SMOKE DETECTORS REAR BASEMENT AREA AND ENCLOSED PORCH AREA [SEPARATED BY DOORS] /SMOKE DETECTOR - MISSING; 1935 W GARFIELD BLVD COMPLAINT FAILED View
CARB MONOX DETECT IN RESID REAR BASEMENT AREA /CARBON MONOXIDE DETECTOR - MISSING; 1935 W GARFIELD BLVD COMPLAINT FAILED View
REPAIR PORCH SYSTEM REAR ENCLOSED PORCH /HEADER [AT BASEMENT] - CUT OUT - MISSING;NOTE: VIEW FROM BASEMENT ONLY - HEADER [AT UNDERSIDE OF 1ST. FL] /DECK JOISTS AND STRINGER - CONNECTION - MISSING; 1935 W GARFIELD BLVD COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT OR RESTORE BUILDING TO THE ORIGINAL STATE. SUBJECT TO FIELD INSPECTION AND APPROVAL BY ALL RELATED TRADES; 1935 W GARFIELD BLVD COMPLAINT FAILED View
REPAIR INTERIOR WALLS/CEILING BASEMENT APT. /BATHROOM CEILING - WATER DAMAGE; FRONT [NORTH] ELEVATION /BASEMENT BEDROOM WALL - WATER DAMAGE [AT WINDOW]; 1935 W GARFIELD BLVD COMPLAINT FAILED View
RELOCATE SMOKE DETECTOR BASEMENT APT. /RELOCATE SMOKE DETECTOR INSTALLED ON THE CEILING TOO CLOSE 2 INCHES TO WALL; 1935 W GARFIELD BLVD COMPLAINT FAILED View
REPAIR/REPLACE SMOKE DETECTORS BASEMENT APT. /SMOKE DETECTOR ¿ OUT OF SERVICE, WITH MISSING BATTERY; 1935 W GARFIELD BLVD COMPLAINT FAILED View