The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR EXTERIOR STAIR | WEST BASEMENT STAIRS NO HANDRAIL. | 1450 W BARRY AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR ENCLOSED PORCH WITH THE FOLLOWING DEFECTIVENESS,NO BOLTS STRINGERS TO SUPPORT POST OR WALL FRAMING, NO BOLTS BEAM TO COLUMN CONNECTIONS, FLOOR JOIST UNDER SIZE 2X6 NO JOIST HANGER ON ANY FLOOR JOISTS, 6X6 COLUMNS SUPPORTING ENCLOSURE SITTING ON TOP OF FLAT ROOF, ALSO BOTH SHOWING SIGNS OF ROTTEN, PLANS & PERMITS REQUIRED FOR REPAIRS. | 1450 W BARRY AVE | COMPLAINT | PASSED | View |
1-HR STAIR ENCLOSURE, <3 STORY | EXPOSED WALL FRAMING THRU-OUT ENCLOSURE REQUIRED 1 HR FIRE RATING. | 1450 W BARRY AVE | COMPLAINT | PASSED | View |
1HR SEP-D.U. AND REST OF BLDG | UNDER SIDE OF 1ST FLOOR ENCLOSED PORCH EXPOSED FRAMING REQUIRED ONE HOUR FIRE RATING. | 1450 W BARRY AVE | COMPLAINT | PASSED | View |
1-HR HEATING PLANT ENCLOSURE | FORCE AIR FURNACE INSTALLED IN REAR ENCLOSED PORCHES REQUIRING IT TO BE ENCLOSED AND HAVE A ONE HOUR FIRE RATING TOP BOTTOM AND ALL FLOOR WALLS WITH A CLASS "B" DOOR. | 1450 W BARRY AVE | COMPLAINT | PASSED | View |
STOP WORK FOR PERMIT | STOP ALL WORK ON HVAC SYSTEM UNTIL PERMIT IS OBTAINED 13-32-110 | 1450 W BARRY AVE | COMPLAINT | PASSED | View |
SUBMIT PLANS/GET VENT PERMIT | DO NOT CONTINUE TO INSTALL HVAC SYSTEM UNTIL APPROVED PLAN IS OBTAINED 13-32-010 13-32-040 13-32-130 13-176-240 13-32-040 13-32-120 | 1450 W BARRY AVE | COMPLAINT | PASSED | View |
ARRANGE COMPLETED PERMIT INSP. | ARRANGE INSPECTION BEFORE ANY WORK IS COVERED OVER 13-176-310 13-184-140 3 STY BLDG-1ST FL COMM & 2ND,3RD FL RES APTS | 1450 W BARRY AVE | COMPLAINT | PASSED | View |
BLANK-TEXT MUST CITE CODE SECT | STOP ALL WORK UNTIL A BUILDING PERMIT HAS BEEN SECURED,SEC.13-32-035,13-12-080. | 1450 W BARRY AVE | COMPLAINT | PASSED | View |
ARRANGE PERMIT INSP. | 1450 W BARRY AVE | PERMIT | PASSED | View | |
PERMIT REQUIRED - CONTRACTOR | PROVIDE ORIGINAL PLANS & PERMITS FOR INSTALLATION OF FURNACES ON REAR PORCHES. | 1450 W BARRY AVE | COMPLAINT | PASSED | View |
PLANS & PERMITS REQ - CONTRCTR | REAR COACH HOUSE - INTERIOR ALTERATIONS GUTT REHAB / PARTITION RECONFIGURATION. | 1450 W BARRY AVE | COMPLAINT | PASSED | View |