| Violation | Inspector Comments | Address | Category | Status | View |
|---|---|---|---|---|---|
| HEAT UNIT ADEQUATELY | NO HEAT, 2ND FL APT., 60 F | 11630 S NORMAL AVE | COMPLAINT | FAILED | View |
| SUPPLY HOT WTR MIN TEMP 120DEG | NO HOT WATER, 2ND FL APT. | 11630 S NORMAL AVE | COMPLAINT | FAILED | View |
| INSTALL SMOKE DETECTORS | NO SMOKE DETECTOR THRU-OUT BUILDING | 11630 S NORMAL AVE | COMPLAINT | FAILED | View |
| CARB MONOX DETECT IN RESID | NO CARBON MONOXIDE DETECTORS | 11630 S NORMAL AVE | COMPLAINT | FAILED | View |
| PROV HOT WTR TO ALL FIXTURES | ALL OCCUPIED UNITS, SR#07-00034800 (18-29-604.5.1) | 11630 S NORMAL AVE | COMPLAINT | FAILED | View |
| RAT STOP AROUND EXTERIOR | AROUND BASE AT REAR PORCH ENCLOSURE | 11630 S NORMAL AVE | COMPLAINT | FAILED | View |
| POST OWNER/MANAGERS NAME/# | POST OWNER I.D. | 11630 S NORMAL AVE | COMPLAINT | FAILED | View |
| REPAIR EAVES | MISSING SECTION OF ALUMINUM EAVES NORTH | 11630 S NORMAL AVE | COMPLAINT | FAILED | View |
| REPLCE WINDOW PANES, PLEXGLAS | BASEMENT WINDOWS BOARDED TWO BROKEN PANE BASEMENT SOUTH 1 AT 1SAT FLOOR EAST | 11630 S NORMAL AVE | COMPLAINT | FAILED | View |
| NOTIFY DOB, USE OF VACANT LND | VACANT BUILDING | 11630 S NORMAL AVE | COMPLAINT | FAILED | View |
| ARRANGE PREMISE INSPECTION | NO ENTRY TO INTERIOR | 11630 S NORMAL AVE | COMPLAINT | FAILED | View |
| SERVICE WALK, PASSAGE, AREAWAY | UNEVEN CONCRETE AT PRIVATE WALK WAY SOUTH ELEVATION | 11630 S NORMAL AVE | COMPLAINT | FAILED | View |
| REPAIR EXTERIOR WALL | MISSING SIDING AT REAR PORCH ENCLOSE SOUTH AND WEST ELEVATIONS | 11630 S NORMAL AVE | COMPLAINT | FAILED | View |
| REPAIR PORCH SYSTEM | FRONT PORCH EAST ELEVATION WEAK TREADS GRADE TO 1ST FLOOR 11'4" SPAN ON 2"X6" FLOOR JOISTS 16" ON CENTER STRINGERS ARE OVER CUT | 11630 S NORMAL AVE | COMPLAINT | FAILED | View |
| MAINTAIN WINDOW | ROTTED WINDOW FRAMES 2ND FLOOR NORTH | 11630 S NORMAL AVE | COMPLAINT | FAILED | View |
| PROVIDE GUARD RAIL 42 IN HIGH | PROVIDE GUARD RAIL FRONT BASEMENT STAIRWELL EAST 38" DROP OFF | 11630 S NORMAL AVE | COMPLAINT | FAILED | View |
| MAINTAIN WINDOW | BROKEN WINDOW FRAME BASEMENT WEST | 11630 S NORMAL AVE | COMPLAINT | FAILED | View |
| DEBRIS, EXCESSIVE | DEBRIS AT FRONT BASEMENT STAIRWELL & JUNK | 11630 S NORMAL AVE | COMPLAINT | FAILED | View |
| STOP/REMOVE NUISANCE | HIGH WEEDS FRONT REAR AND SOUTH SIDES | 11630 S NORMAL AVE | COMPLAINT | FAILED | View |
| REPAIR FENCE | DILAPIDATE CHAIN LINK FENCE AT REAR YARD | 11630 S NORMAL AVE | COMPLAINT | FAILED | View |
| SCREEN OUTER DOORS, WINDOWS | MISSING SCREENS 1SAT AND SECOND FLOORS WEST MISSING FRONT & REAR SCREEN DOORS BASEMENT AND 1SAT FLOOR | 11630 S NORMAL AVE | COMPLAINT | FAILED | View |
| RATS | REAR IS A RAT HARBORAGE | 11630 S NORMAL AVE | COMPLAINT | FAILED | View |
| RAT PROOF EXTERIOR DOOR | BASEMENT DOOR EAST AND GRADE DOOR ENTRANCE SOUTH | 11630 S NORMAL AVE | COMPLAINT | FAILED | View |
| RAT PROOF BSMENT DOOR | BASEMENT DOOR EAST | 11630 S NORMAL AVE | COMPLAINT | FAILED | View |
| REPAIR DOWNSPOUT | MISSING SECTION OF DOWN SPOUT SOUTH ELEVATION | 11630 S NORMAL AVE | COMPLAINT | FAILED | View |
| DEFECTIVE METER EQUIPMENT | METER BOX OUTSIDE REAR | 11630 S NORMAL AVE | COMPLAINT | FAILED | View |
| SECURE RACEWAY | SERVICE POLE OUTSIDE REAR | 11630 S NORMAL AVE | COMPLAINT | FAILED | View |
| VACANT BUILDING - REGISTER | INSPECTED BY BL00627 ON 18-AUG-10 AND RE-INSPECTED BY BL00627 ON 13-OCT-10. DEPT. OF BUILDINGS DATABASE REVIEWED ON 01-NOV-10 BY BL00393. NO PROOF OF REGISTRATION AS OF 18-AUG-10 AND 13-OCT-10 :: | 11630 S NORMAL AVE | COMPLAINT | CLOSED | View |
| VACANT BUILDING - REGISTER | 11630 S NORMAL AVE | COMPLAINT | CLOSED | View | |
| ARRANGE FOR REINSPECTION REGAR | ENTIRE BUILDING | 11630 S NORMAL AVE | COMPLAINT | FAILED | View |
| PLANS & PERMITS REQ - CONTRCTR | OBTAIN PERMIT FOR BUT NOT LIMITED TOO: 1) NEW FRONT PORCH: 2) REDUCTION OF WINDOW SIZE AT 1SAT FLOOR WEST ELEVATION. | 11630 S NORMAL AVE | COMPLAINT | FAILED | View |
| REPUTTY WINDOW PANES | LOOSE & MISSING WINDOW PUTTY 2ND FLOOR WEST | 11630 S NORMAL AVE | COMPLAINT | FAILED | View |