Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-23 @ 11:49 PM
PIN: 16233050190000
Property Address: 1655 S RIDGEWAY AVE
City - Zip: CHICAGO - 60623
2023 Property Class: 211
2023 Township: 77 - West Chicago
2023 Neighborhood: 77091
2023 Tax District: 77125
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 41 Violations
Violation Inspector Comments Address Category Status View
TENANT ACCESS TO SERVICE NO TENANT ACCESS TO MAIN SWITCH LOCATED BASEMENT UNIT 1655 S RIDGEWAY AVE COMPLAINT FAILED View
EXPOSED WIRING FIXTURES EXPOSED WIRES IN BASEMENT UNIT NEAR PANELS D&H 1655 S RIDGEWAY AVE COMPLAINT FAILED View
DEFECTIVE METER EQUIPMENT DETECTIVE METER BOX & MISSING METER D&H 1655 S RIDGEWAY AVE COMPLAINT FAILED View
CIRCUIT ONE UNIT ONLY 3 UNIT BUILDING NEED PUBLIC METER 1655 S RIDGEWAY AVE COMPLAINT FAILED View
WORKING SPACE NEED TO PROVIDE 3 FEET OF SPACE AT PANEL 1655 S RIDGEWAY AVE COMPLAINT FAILED View
ADD RECEPTACLES ADD GFCI TO COUNTER TOP BASEMENT KITCHEN 1655 S RIDGEWAY AVE COMPLAINT FAILED View
ADD RECEPTACLES ADD OUTLETS TO EASE CORD USE 1655 S RIDGEWAY AVE COMPLAINT FAILED View
DEFECTIVE OUTLETS DEFECTIVE OUTLETS THOUGHT OUT BASEMENT 1655 S RIDGEWAY AVE COMPLAINT FAILED View
BOND AROUND FITTINGS VERIFY COLD WATER GROUND 1655 S RIDGEWAY AVE COMPLAINT FAILED View
CIRCUIT ONE UNIT ONLY RESOLVE MIXED CIRCUITS 1ST FLOOR AND BASEMENT 1655 S RIDGEWAY AVE COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# BLDG. - OWNER'S I.D. SIGN - MISSING. 1655 S RIDGEWAY AVE COMPLAINT FAILED View
REPLACE D&H PORCH 2-STORY REAR WOODEN PORCH: 4X4 AND 6X6 COLUMNS ERECTED ON CONCRETE BLOCKS AND SERVICE WALKS - FOUNDATION STATUS UNKNOWN. 4X4 COLUMNS ARE BUTT-JOINTED, AND 6X6 COLUMNS SPLICE CONNECTIONS ARE ONLY 7 INCHES OVERLAPS WITH ONLY A BOLT THRU-OUT. COLUMNS ARE BOWING AT POINTS OF CONNECTIONS. TREAD WIDTH THRU-OUT ARE ONLY 9 INCHES, WITH RISER BOARD MISSING AT GRADE. RAILS LOOSE AND PULLING, WITH GUARDRAIL PICKETS BROKEN AND MISSING. GUARDRAIL HEIGHT ARE ONLY 38 INCHES AND SPAN 8' TO 12' WITHOUT INTERMIDATE 4X4 POSTS. RAILS ATTACHED TO WALL AND COLUMNS WITH ONLY NAILS. 2X8 RIM BEAM AT 2 DISCONNECTED FROM COLUMN. STRINGERS ARE ONLY TOE-NAILED TO COLUMNS. DECKBOARDS ARE ROTTING, BROKEN, TWISTING AND MISSING SECTIONS. LANDING JOISTS ARE ONLY TOE-NAILED TO RIM BEAMS. ENTIRE STRUCTURE IS WEAK, UNSTABLE AND SWAYING. PLANS AND PERMIT REQUIRED TO REPLACE REAR PORCH. 1655 S RIDGEWAY AVE COMPLAINT FAILED View
REPAIR CATCH BASIN REAR YARD - CATCH BASIN - CRACKED AND SINKING. 1655 S RIDGEWAY AVE COMPLAINT FAILED View
DEFECTIVE FIXTURES REAR PORCH AT 1 AND 2 - LIGHT FIXTURES BROKEN AND MISSING BUILBS. BASEMENT APARTMENT - UTILITY ROOM - LIGHT FIXTURE LOOSE AND HANGING. 1655 S RIDGEWAY AVE COMPLAINT FAILED View
DEFECTIVE OUTLETS BASEMENT APARTMENT - LIVING ROOM - OUTLET LOOSE AND BROKEN. 1655 S RIDGEWAY AVE COMPLAINT FAILED View
USE SANITARY REFUSE CONTAINERS REAR PORCH AT 1 AND 2 - ACCUMULATION OF REFUSE AND GARBAGE. 1655 S RIDGEWAY AVE COMPLAINT FAILED View
DEBRIS, EXCESSIVE REAR PORCH BASEMENT, 1 AND 2 - JUNK AND DEBRIS ACCUMULATION. 1655 S RIDGEWAY AVE COMPLAINT FAILED View
NO CLOSET/STORAGE UNDER STAIR TWO LAWN MOWERS STORED UNDER THE PORCH 1655 S RIDGEWAY AVE COMPLAINT FAILED View
PARTITIONS, N/L/B - BASEMENT BASEMENT APARTMENT - KITCHEN AND BEDROOMS - PARTITIONS ARE ONLY 1/2 INCH DRYWALLS AND PANELLING, WITH OPEN WALLS AND CEILINGS - EXPOSING WOOD STUDS AND INSULATION MATERIALS. 1655 S RIDGEWAY AVE COMPLAINT FAILED View
REPAIR INTERIOR WALLS/CEILING BASEMENT APARTMENT - KITCHEN AND BATHROOM - WALLS AND CEILINGS - WATER DAMAGE. 1655 S RIDGEWAY AVE COMPLAINT FAILED View
REPAIR FLOOR BASEMENT APARTMENT - LOOSE AND BUCKLING FLOORING THRU-OUT. 1655 S RIDGEWAY AVE COMPLAINT FAILED View
RESET LOOSE FIXTURE BASEMENT APARTMENT - BATHROOM - LOOSE AND PULLING TOILET. 1655 S RIDGEWAY AVE COMPLAINT FAILED View
REPAIR EXTERIOR DOOR FRAME BASEMENT APARTMENT - BATHROOM DOOR FRAME - UNFINSHED TRIM AND MOLDING. 1655 S RIDGEWAY AVE COMPLAINT FAILED View
CARB MONOX DETECT IN RESID BASEMENT APARTMENT - CARBON MONOXIDE DETECTOR - OUT OF SERVICE. 1655 S RIDGEWAY AVE COMPLAINT FAILED View
REPAIR SCREENS ALL ELEVATIONS - TORN AND MISSING SCREENS. 1655 S RIDGEWAY AVE COMPLAINT FAILED View
REPAIR EXTERIOR STAIR FRONT GRADE TO 1 / STAIRWAY - RAILINGS LOOSE AND PULLING, WITH NEWEL POST ROTTING. GUARDRAIL HEIGHT ONLY 39 INCHES. 1655 S RIDGEWAY AVE COMPLAINT FAILED View
CHIMNEY CHIMNEY - LEANING INWARD, WITH LOOSE AND SPALLING BRICKS. 1655 S RIDGEWAY AVE COMPLAINT FAILED View
WORK NOT ALLOWED BASEMENT ALTERED INTO A DWELLING UNIT. REMOVE ALL PARTITIONS AND FIXTURES (INCLUDING PLUMBING AND ELECTRIC) INSTALLED IN THE BASEMENT WITHOUT A PERMIT. 1655 S RIDGEWAY AVE COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT, OR RESTORE THE BUILDING TO THE ORIGINAL STATE. 1655 S RIDGEWAY AVE COMPLAINT FAILED View
FOUNDATION, ADEQUATELY SUPPORT ALL ELEVATION - FOUNDATION WALLS - OPENING AROUND THE PERIMETER WALLS, WITH WATER SEEPING INTO THE BASEMENT APARTMENT. 1655 S RIDGEWAY AVE COMPLAINT FAILED View
REPAIR FENCE REAR CHAIN-LINKED FENCE - BROKEN, WITH TOP RAIL DISCONNECTED. 1655 S RIDGEWAY AVE COMPLAINT FAILED View
ROACHES BASEMENT APARTMENT - ROACHES INFESTATION. 1655 S RIDGEWAY AVE COMPLAINT FAILED View
STOP LEAKING WATER BASEMENT APARTMENT - KITCHEN AND BATHROOM CEILINGS - WATER LEAKAGE. 1655 S RIDGEWAY AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING- NO ENTRY, UNABLE TO VERIFY COMPLAINT OF SEWAGE SMELL. 1655 S RIDGEWAY AVE COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# NO OWNER'S ID SIGN POSTED. 1655 S RIDGEWAY AVE COMPLAINT FAILED View
SCREEN OUTER DOORS, WINDOWS WINDOWS SCREENS AND STORM PANES MISSING. 1655 S RIDGEWAY AVE COMPLAINT FAILED View
CHIMNEY SOUTH CHIMNEY PARTLY REMOVE, WASHED OUT MORTAR AND SPALLING BRICKS. 1655 S RIDGEWAY AVE COMPLAINT FAILED View
OBSTRUCTIONS IN EXIT WAY GATE PADLOCK. 1655 S RIDGEWAY AVE COMPLAINT FAILED View
PROVID SELF CLSING SCREEN DVCE ENTIRE BUILDING, INCLUDING BASEMENT APARTMENT - EXTERIOR DOORS - MISSING SELF-CLOSING SCREEN DEVICES. 1655 S RIDGEWAY AVE COMPLAINT FAILED View
SUPPORT FIXTURES HANGING LIGHT IN PANEL ROOM BASEMENT 1655 S RIDGEWAY AVE COMPLAINT FAILED View
STOP/REMOVE NUISANCE REAR YARD - BOAT ABANDONED. 1655 S RIDGEWAY AVE COMPLAINT FAILED View