The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR EXTERIOR WALL | SR#06-01707664 BRICKS BULGING OVER 2ND FLOOR WINDOWS (NORTH) | 716 N TROY ST | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | REAR PORCH COLUMNS ERECTED ON TOP OF CONCRETE SLAP FOUNDATION STATUS UNKNOWN COLUMN ARE ONLY 4X4 AND 6X6 OUT OF PLUMB(BOWING TWISTING) WITH INADEQUATE HALF-LAP LEDGER BEAMS (ROTTING) AND STRINGERS ATTACHED TO BUILDINGS EXTERIOR WALLS WITH NAILS ONLY FEAR JOISTS ARE TOP NAILED TO HEADER JOISTS THRU-OUT STRINGERS ARE INADEQUATELY SUPPORTED AT COLUMNS RAILING SECTION ARE ONLY 30" HIGH LOOSE AND PULLING ESPECIALLY BOTTOM RAILS DECKS ARE WEAK WITH ROTTING FLOOR BOARDS TREADS ARE CRACKED WORN OUT ONLY 8" WIDE 1ST FLOOR GUARD RAILS MISSING ENTIRELY ENTIRE PORCH STRUCTURE IS UNSTABLE AND SWAYING OBTAIN PLANS AND PERMITS TO REPLACE DANGEROUS AND HAZARDOUS REAR PORCH PORCH POSTED DANGEROUS AND HAZARDOUS | 716 N TROY ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR PLATFORM | REAR YARD CONCRETE PLATFORM CRACKED BROKEN UP | 716 N TROY ST | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | JUNK AND DEBRIS REAR YARD | 716 N TROY ST | COMPLAINT | FAILED | View |
POST OWNER NAME OF VACNT BLDG | POST OWNER'S ID SIGN FOR VACANT AND SECURED RESIDENTIAL PREMISES | 716 N TROY ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING UNVERIFIED DETECTORS | 716 N TROY ST | COMPLAINT | FAILED | View |
PARAPET | BLDG. - MISSING OWNER'S I.D. SIGN. | 716 N TROY ST | COMPLAINT | FAILED | View |
PARAPET | NORTH AND SOUTH PARAPET WALLS - LOOSE AND SPALLING BRICKS, WITH WASHED OUT MORTAR. | 716 N TROY ST | COMPLAINT | FAILED | View |
CHIMNEY | NORTH AND SOUTH CHIMNEY - WASHED OUT MORTAR. | 716 N TROY ST | COMPLAINT | FAILED | View |
REPAIR LINTELS | NORTH AT 2 - WINDOW LINTEL RUSTING WITH LOOSE AND SAGGING BRICKS. | 716 N TROY ST | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | NORTH GANGWAY - SERVICE WALKS - BROKEN CONCRETE. | 716 N TROY ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | 2-STORY / REAR PORCH: RAILING AND GUARDRAIL SECTIONS ARE LOOSE AND PULLING, WITH LOOSE, BROKEN AND MISSING PICKETS. LEDGER BOARD LAG BOLTS SPACED 32 INCHES APART. TREADS LOOSE AND SPLIT FROM GRADE TO 1. PERMIT ONLY (NO PLANS) REQUIRED TO REPAIR REAR PORCH. | 716 N TROY ST | COMPLAINT | FAILED | View |
REPAIR CATCH BASIN | REAR YARD - CATCH BASIN COLLAR - BROKEN CONCRETE, WITH LOOSE AND UNSECURED COVER. | 716 N TROY ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BLDG. - ENTRY REFUSED BY 1ST FLOOR TENANT - UNVERIFIED DETECTOS AND CONDITIONS. | 716 N TROY ST | COMPLAINT | FAILED | View |
REPAIR/WRECK DANGER RESID PREM | 716 N TROY ST | COMPLAINT | CLOSED | View | |
VACANT BUILDING - REGISTER | 716 N TROY ST | COMPLAINT | CLOSED | View | |
POST OWNER INFO ON ABDN BLDG | 716 N TROY ST | COMPLAINT | CLOSED | View | |
SUBMIT FOR APPROVAL PLANS | 716 N TROY ST | COMPLAINT | CLOSED | View | |
MAINTAN BLDG IN SAFE CONDITION | 716 N TROY ST | COMPLAINT | CLOSED | View | |
WATCHMAN | 716 N TROY ST | COMPLAINT | CLOSED | View | |
POST OWNER NAME OF VACNT BLDG | VIOLATIONS CLOSED WHEN INSPECTION IS CLOSED OR CANCELLED | 716 N TROY ST | COMPLAINT | CLOSED | View |
REPAIR LINTELS | LINTEL (NORTH) 2ND FLOOR SAGGING/ROTTED | 716 N TROY ST | COMPLAINT | FAILED | View |