Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-08-30 @ 5:11 PM
PIN: 14054070171137
Property Address: 5701 N SHERIDAN RD
City - Zip: CHICAGO - 60660
2023 Property Class: 299
2023 Township: 73 - Lake View
2023 Neighborhood: 73031
2023 Tax District: 73105
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 48 Violations
Violation Inspector Comments Address Category Status View
PROVIDE GUARD RAIL 42 IN HIGH GAURD RAILS AT SUNDECK/POOL AREA ARE INADEQUATE; MEASURING 3" TO 8" BETWEEN PLEXIGLASS PANELS AND 8" OPENING AT BOTTOM - FLOOR TO BOTTOM RAIL. HEIGHT REQUIRMENT IS 42" MIN., SPACING BETWEEN VERTICAL MEMBERS MUST BE LESS THAN 4". SPACING AT BOTTOM OPENING MUST BE LESS THAN 4". 5701 N SHERIDAN RD PERIODIC FAILED View
FIRE EXTNGSHR RECHARGE & TAG EXPIRED FIRE EXTINGUISHERS STAIRWAYS 5701 N SHERIDAN RD PERIODIC FAILED View
CLASS B DOOR IN STAIRWELL MISSING FIRE RATING LABELS FROM STAIRWAY DOORS 5701 N SHERIDAN RD PERIODIC FAILED View
ARRANGE PREMISE INSPECTION INTERIOR/APT.24-A TO INSPECT COMPLAINT OF BROKEN WINDOW/NO ENTRY 5729 NORTH TOWER TO INSPECT STAIRWAYS AND APTS. 5701 N SHERIDAN RD PERIODIC FAILED View
FIRE EXTNGSHR RECHARGE & TAG EXPIRED FIRE EXTINGUISHERS STAIRWAYS 5701 N SHERIDAN RD PERIODIC FAILED View
CLASS B DOOR IN STAIRWELL MISSING LABLES SOUTH BUILDING 24-28, 8TH AND 6TH FLOORS. 5701 N SHERIDAN RD PERIODIC FAILED View
ARRANGE PREMISE INSPECTION INTERIOR/APT.24-A TO INSPECT COMPLAINT OF BROKEN WINDOW/NO ENTRY 5729 NORTH TOWER TO INSPECT STAIRWAYS AND APTS. 5701 N SHERIDAN RD PERIODIC FAILED View
ARRANGE COMPLETED PERMIT INSP. 5701 N SHERIDAN RD PERIODIC PASSED View
GIVE VENT OPENINGS % FL. AREA PROVIDE MECHANICAL EXHAUST VENTILATION IN BEAUTY PARLOR & MESSAGE RM ETC PER 18-28-403.3 5701 N SHERIDAN RD PERIODIC PASSED View
MAINTAIN MECH. VENT SYSTEM MAINTAIN MECHANICAL VENTILATION EQUIPMENT IN GOOD REPAIR & OPERATE TO PROVIDE ADEQUATE VENTILATION SUPPLY AIR FOR GARAGE 5701 N SHERIDAN RD PERIODIC PASSED View
REPAIR EXTERIOR DOOR FRAME INTERIOR STAIRWELL DOORS OVERLAPS JAMB NORTH BUILDING 5,6,AND 23. SOUTH BUILDING 11TH FLOOR CHUTE ROOM, 8TH,AND 6TH FLOORS STAIRWELLS. 5701 N SHERIDAN RD PERIODIC FAILED View
CARB MONOX DETECT IN RESID INTERIOR 2ND FLOOR NORTH BUILDING LAUNDRY ROOM MISSING C02 DETECORS. 5701 N SHERIDAN RD PERIODIC FAILED View
CLASS B DOOR IN STAIRWELL MISSING LABLES SOUTH BUILDING 24-28, 8TH AND 6TH FLOORS. 5701 N SHERIDAN RD PERIODIC FAILED View
REPAIR EXTERIOR DOOR FRAME INTERIOR STAIRWELL DOORS OVERLAPS JAMB NORTH BUILDING 30E,23W,6E,5W, SOUTH BUILDING ,11W, 8E, AND 6W. 5701 N SHERIDAN RD PERIODIC FAILED View
CARB MONOX DETECT IN RESID INTERIOR 2ND FLOOR NORTH BUILDING LAUNDRY ROOM MISSING C02 DETECORS. 5701 N SHERIDAN RD PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA ALL ELEVATORS: A CURRENT FIRE SERVICE MONTHLY TEST LOG IS REQUIRED ON SITE. 5701 N SHERIDAN RD PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA ALL ELEVATORS: CLEAN PITS. 5701 N SHERIDAN RD PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA ELEVATORS 4 AND 5: THE DOOR HOLD BUTTON IN CAR OPERATING PANEL MUST BE DISABLED WHEN ON PHASE 2 FIRE SERVICE. 5701 N SHERIDAN RD PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA ELEVATORS 6 AND 7: REPAIR MALFUNCTIONING DOOR RESTRICTOR. 5701 N SHERIDAN RD PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA ELEVATORS 1 AND 3: REPAIR MALFUNCTIONING 2 WAY COMMUNICATION (PHONE). 5701 N SHERIDAN RD PERIODIC FAILED View
PROVIDE CLASS A FIRE DOOR BASEMENT AND SECOND LEVEL OF PARKING GARAGE - MISSING VESTIBLE WITH TWO 3 HOUR A LABELED RATED DOORS ON EACH SIDE OF 4 HOUR SEPARATION . ONLY ONE 3 HOUR LABEL DOOR PROVIDED . 5701 N SHERIDAN RD PERIODIC FAILED View
REPAIR EXTERIOR DOOR, RESET NORTH SERVICE DOOR EXIT FROM GARAGE ( BY TRASH CARTS ) RUBS ON FRAME , HARD TO OPEN . 5701 N SHERIDAN RD PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA ELEVATORS 2 AND 7: REPAIR MALFUNCTIONING ALARM BELL. 5701 N SHERIDAN RD PERIODIC PASSED View
INSTALL EXIT SIGN EXIT SIGN DIRECTIONAL MISSING IN LOWER AND UPPER LEVEL OF PARKING GARAGE . NORTH BASEMENT BOILER / PUMP ROOMS , FIRST FLOOR CORRIDOR , SOUTH HAIR SALON, MINI MART , LARGE TENANT STORAGE ROOMS , POOL DECK AT SECOND FLOOR , SECOND FLOOR PARTY ROOM AND ATTACHED NORTH AND SOUTH CORRIDORS. ELECTRICAL PERMIT REQUIRED . 5701 N SHERIDAN RD PERIODIC FAILED View
RESTORE EXIT AND EM ALL FLOORS AND GARAGE - STAIRWAY AND EXIT SIGNS MISSING BATTERY BACK-UP . 5701 N SHERIDAN RD PERIODIC FAILED View
PROVIDE PROVIDE PER CODE SECTION 13-76-075 STAIRWELL IDENTIFICATION . STAIRWELL IDENTIFICATION MISSING AT EACH FLOOR ON INTERIOR SIDE OF STAIRWELL . UPPER AND LOWER LEVELS OF GARAGE , FLOORS LEVELS NOT MARKED WITH SIGNAGE AND GARAGE ONLY STAIRS MISSING SIGNAGE . 5701 N SHERIDAN RD PERIODIC FAILED View
I-A I-B I-C AND II FIRE RESIST UPPER AND LOWER LEVELS OF PARKING GARAGE - REMOVE ALL WOOD PARTITIONS , WOOD STORAGE UNITS AND SHEDS CONSTRUCTED IN GARAGE AND RETURN TO ORIGINAL STATE OR PROVIDE PLANS AND OBTAIN PERMIT FOR RENOVATION . 5701 N SHERIDAN RD PERIODIC FAILED View
PROVIDE PROVIDE PER SECTION CODE 13-196-204 ONE WAY AND TWO WAY VOICE COMMUNICATION SYSTEMS. ONE WAY AND TWO WAY VOICE COMMUNICATION SYSTEMS , INSTALLATION NOT COMPLETE AT TIME OF LIFE SAFETY INSPECTION . 5701 N SHERIDAN RD PERIODIC FAILED View
REPAIR INTERIOR WALLS/CEILING LOWER LEVEL OF PARKING GARAGE - CONCRETE CEILING ,SPALLED, LOOSE , FLAKING MASONRY COATING , WITH SPALLED AREAS WITH RUSTED AND EXPOSED REBARS . LOOSE PREVIOUS REPAIRS . MASONRY REPAIR PERMIT REQUIRED . 5701 N SHERIDAN RD PERIODIC FAILED View
DEBRIS, EXCESSIVE UPPER AND LOWER LEVELS OF PARKING GARAGE - REMOVE COMBUSTIBLE STORAGE AND EXCESSIVE DEBRIS . 5701 N SHERIDAN RD PERIODIC FAILED View
WORK NOT ALLOWED REMOVE ALL WOOD FRAMED PARTITIONS (SMALL STORAGE ROOM ) INSTALLED AT THE SOUTH CORRIDOR ( ACROSS FROM HAIR SALON WINDOWS ) WITHOUT A PERMIT . 5701 N SHERIDAN RD PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA CODE DATA TAGS LOCATED ON CONTROLLERS MUST BE FILLED OUT. THEY ARE CURRENTLY BLANK - ELEVATORS 5701 N SHERIDAN RD PERIODIC PASSED View
MAINTAIN OR REPAIR ELECT ELEVA MAINTAIN A CURICUT FIVE SERVICE MONTHLY TEST LOG ON SUTE (PRIVIDED) - ALL EVEVATORS 5701 N SHERIDAN RD PERIODIC PASSED View
MAINTAIN OR REPAIR ELECT ELEVA NORTH TOWER PASSENGER ELEVATORS OD NOT RESPOND TO PHASE 1 COMMAND - REPAIR SAME 5701 N SHERIDAN RD PERIODIC PASSED View
MAINTAIN OR REPAIR ELECT ELEVA REPAIR MALFUNCTIONING DOOR RESTRICTORS ON ELEVATORS 3,4,5,6,7, AND 8 5701 N SHERIDAN RD PERIODIC PASSED View
MAINTAIN OR REPAIR ELECT ELEVA REPAIR MALFUNCATIONING 2- WAY COMMUNICATION (PHONE) IN ELEVATOR CAB #5 5701 N SHERIDAN RD PERIODIC PASSED View
SELF-CLOSE DOOR >4 STORY RES. ALL FLOORS - APARTMENT DOORS NOT CLOSING AND LATCHING . 5701 N SHERIDAN RD PERIODIC FAILED View
1HR PUB.CORRIDOR IN MULT. D.U. BASEMENT , FIRST AND SECOND FLOORS , ALL DOORS IN CORRIDORS REQUIRE FIRE RATED DOOR AND SELF CLOSING DEVICES . NORTH AND SOUTH LAUNDRY ROOMS , PUMP ROOM , TENANT STORAGE ROOMS , BIKE STORAGE ROOM ( FULL GLASS DOOR ), SOUTH HAIR SALON , NORTH MINI MART ( FULL GLASS DOOR ) , ELECTRICAL ROOMS , AT & T ROOMS AND EQUIPMENT ROOMS . SECOND FLOOR NORTH AND SOUTH LAUNDRY ROOMS AND FIRST FLOOR HAIR SALON AT SOUTH - LARGE GLASS HALF WALL WINDOWS NOT FIRE RATED . 5701 N SHERIDAN RD PERIODIC FAILED View
CLASS B DOOR IN STAIRWELL SOUTH BASEMENT AND SOUTH FIRST FLOOR STAIRWAY DOORS MISSING FIRE RATED TAGS . 5701 N SHERIDAN RD PERIODIC FAILED View
ROACHES UNIT #16H - DEAD ROACH INSIDE BATHROOM VANITY 5701 N SHERIDAN RD COMPLAINT CLOSED View
ARRANGE PREMISE INSPECTION UNABLE TO INSPECT COMPLETE INTERIOR, STAIRWELLS, APARTMENTS, BASEMENT, AND GARAGE. UNVERIFIED DETECTORS AND CONDITIONS. 5701 N SHERIDAN RD COMPLAINT FAILED View
REPAIR ROOF LOBBY ROOF/SOUTHWEST CORNER - CHIPPED OFF SECTION OF CONCRETE SLAB, WITH EXPOSED AND RUSTING RE-BARS.SOUTH TOWER/1ST FLOOR ROOF/SOUTH ELEVATION - CHIPPED OFF SECTIONS OF CONCRETE SLAB, WITH EXPOSED AND RUSTING RE-BARS. NORTH TOWER/1ST FLOOR ROOF/NORTH ELEVATION - CHIPPED OFF SECTIONS OF CONCRETE SLAB, WITH EXPOSED AND RUSTING RE-BARS. 5701 N SHERIDAN RD COMPLAINT FAILED View
STRUCTURAL MEMBER, PIER BLOCK NORTH TOWER/SOUTHWEST CORNER AND NORTH ELEVATION/3RD FLOOR CONCRETE SLABS - CHIPPED-OFF SECTIONS OF CONCRETE, WITH EXPOSED AND RUSTING RE-BARS.SOUTH TOWER/SOUTH ELEVATION/3RD FLOOR CONCRETE SLAB - CHIPPED-OFF SECTIONS OF CONCRETE, WITH EXPOSED AND RUSTING RE-BARS. 5701 N SHERIDAN RD COMPLAINT FAILED View
REPAIR FENCE NORTHWEST CORNER/PARKING LOT CONCRETE FENCE - SOUTHERN CONCRETE PANEL OUT OF PLUMB AND LEANING DUE WEST. 5701 N SHERIDAN RD COMPLAINT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA ALL ELEVATORS: PERFORM CATEGORY 5 TEST. TAG AND DOCUMENT AS REQUIRED. 5701 N SHERIDAN RD PERIODIC FAILED View
OBSTRUCTIONS IN EXIT WAY BASEMENT PARKING GARAGE -EXIT DOORS AT NORTH AND SOUTH ARE LOCKED AND REQUIRE A KEY TO EXIT INTO BUILDING AT EGRESS SIDE . NO FAIL SAFE INSTALLED . 5701 N SHERIDAN RD PERIODIC FAILED View
PROVIDE PROVIDE PER SECTION CODE 18-27-700.6 EMERGENCY LIGHTING . EMERGENCY LIGHTING MISSING IN NORTH BASEMENT BOILER / PUMP ROOMS . ELECTRICAL PERMIT REQUIRED . 5701 N SHERIDAN RD PERIODIC FAILED View
ARRANGE FOR REINSPECTION REGAR INTERIOR OF BUILDING MOST APARTMENTS NO RESPONSE. UNVERIFIED DETECTORS AND CONDITIONS. UNVERIFIED COMPLAINT OF APT. 4T - MICE. 5701 N SHERIDAN RD PERIODIC PASSED View