Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
PROVIDE GUARD RAIL 42 IN HIGH | GAURD RAILS AT SUNDECK/POOL AREA ARE INADEQUATE; MEASURING 3" TO 8" BETWEEN PLEXIGLASS PANELS AND 8" OPENING AT BOTTOM - FLOOR TO BOTTOM RAIL. HEIGHT REQUIRMENT IS 42" MIN., SPACING BETWEEN VERTICAL MEMBERS MUST BE LESS THAN 4". SPACING AT BOTTOM OPENING MUST BE LESS THAN 4". | 5701 N SHERIDAN RD | PERIODIC | FAILED | View |
FIRE EXTNGSHR RECHARGE & TAG | EXPIRED FIRE EXTINGUISHERS STAIRWAYS | 5701 N SHERIDAN RD | PERIODIC | FAILED | View |
CLASS B DOOR IN STAIRWELL | MISSING FIRE RATING LABELS FROM STAIRWAY DOORS | 5701 N SHERIDAN RD | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR/APT.24-A TO INSPECT COMPLAINT OF BROKEN WINDOW/NO ENTRY 5729 NORTH TOWER TO INSPECT STAIRWAYS AND APTS. | 5701 N SHERIDAN RD | PERIODIC | FAILED | View |
FIRE EXTNGSHR RECHARGE & TAG | EXPIRED FIRE EXTINGUISHERS STAIRWAYS | 5701 N SHERIDAN RD | PERIODIC | FAILED | View |
CLASS B DOOR IN STAIRWELL | MISSING LABLES SOUTH BUILDING 24-28, 8TH AND 6TH FLOORS. | 5701 N SHERIDAN RD | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR/APT.24-A TO INSPECT COMPLAINT OF BROKEN WINDOW/NO ENTRY 5729 NORTH TOWER TO INSPECT STAIRWAYS AND APTS. | 5701 N SHERIDAN RD | PERIODIC | FAILED | View |
ARRANGE COMPLETED PERMIT INSP. | 5701 N SHERIDAN RD | PERIODIC | PASSED | View | |
GIVE VENT OPENINGS % FL. AREA | PROVIDE MECHANICAL EXHAUST VENTILATION IN BEAUTY PARLOR & MESSAGE RM ETC PER 18-28-403.3 | 5701 N SHERIDAN RD | PERIODIC | PASSED | View |
MAINTAIN MECH. VENT SYSTEM | MAINTAIN MECHANICAL VENTILATION EQUIPMENT IN GOOD REPAIR & OPERATE TO PROVIDE ADEQUATE VENTILATION SUPPLY AIR FOR GARAGE | 5701 N SHERIDAN RD | PERIODIC | PASSED | View |
REPAIR EXTERIOR DOOR FRAME | INTERIOR STAIRWELL DOORS OVERLAPS JAMB NORTH BUILDING 5,6,AND 23. SOUTH BUILDING 11TH FLOOR CHUTE ROOM, 8TH,AND 6TH FLOORS STAIRWELLS. | 5701 N SHERIDAN RD | PERIODIC | FAILED | View |
CARB MONOX DETECT IN RESID | INTERIOR 2ND FLOOR NORTH BUILDING LAUNDRY ROOM MISSING C02 DETECORS. | 5701 N SHERIDAN RD | PERIODIC | FAILED | View |
CLASS B DOOR IN STAIRWELL | MISSING LABLES SOUTH BUILDING 24-28, 8TH AND 6TH FLOORS. | 5701 N SHERIDAN RD | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR FRAME | INTERIOR STAIRWELL DOORS OVERLAPS JAMB NORTH BUILDING 30E,23W,6E,5W, SOUTH BUILDING ,11W, 8E, AND 6W. | 5701 N SHERIDAN RD | PERIODIC | FAILED | View |
CARB MONOX DETECT IN RESID | INTERIOR 2ND FLOOR NORTH BUILDING LAUNDRY ROOM MISSING C02 DETECORS. | 5701 N SHERIDAN RD | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ALL ELEVATORS: A CURRENT FIRE SERVICE MONTHLY TEST LOG IS REQUIRED ON SITE. | 5701 N SHERIDAN RD | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ALL ELEVATORS: CLEAN PITS. | 5701 N SHERIDAN RD | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ELEVATORS 4 AND 5: THE DOOR HOLD BUTTON IN CAR OPERATING PANEL MUST BE DISABLED WHEN ON PHASE 2 FIRE SERVICE. | 5701 N SHERIDAN RD | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ELEVATORS 6 AND 7: REPAIR MALFUNCTIONING DOOR RESTRICTOR. | 5701 N SHERIDAN RD | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ELEVATORS 1 AND 3: REPAIR MALFUNCTIONING 2 WAY COMMUNICATION (PHONE). | 5701 N SHERIDAN RD | PERIODIC | FAILED | View |
PROVIDE CLASS A FIRE DOOR | BASEMENT AND SECOND LEVEL OF PARKING GARAGE - MISSING VESTIBLE WITH TWO 3 HOUR A LABELED RATED DOORS ON EACH SIDE OF 4 HOUR SEPARATION . ONLY ONE 3 HOUR LABEL DOOR PROVIDED . | 5701 N SHERIDAN RD | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR, RESET | NORTH SERVICE DOOR EXIT FROM GARAGE ( BY TRASH CARTS ) RUBS ON FRAME , HARD TO OPEN . | 5701 N SHERIDAN RD | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ELEVATORS 2 AND 7: REPAIR MALFUNCTIONING ALARM BELL. | 5701 N SHERIDAN RD | PERIODIC | PASSED | View |
INSTALL EXIT SIGN | EXIT SIGN DIRECTIONAL MISSING IN LOWER AND UPPER LEVEL OF PARKING GARAGE . NORTH BASEMENT BOILER / PUMP ROOMS , FIRST FLOOR CORRIDOR , SOUTH HAIR SALON, MINI MART , LARGE TENANT STORAGE ROOMS , POOL DECK AT SECOND FLOOR , SECOND FLOOR PARTY ROOM AND ATTACHED NORTH AND SOUTH CORRIDORS. ELECTRICAL PERMIT REQUIRED . | 5701 N SHERIDAN RD | PERIODIC | FAILED | View |
RESTORE EXIT AND EM | ALL FLOORS AND GARAGE - STAIRWAY AND EXIT SIGNS MISSING BATTERY BACK-UP . | 5701 N SHERIDAN RD | PERIODIC | FAILED | View |
PROVIDE | PROVIDE PER CODE SECTION 13-76-075 STAIRWELL IDENTIFICATION . STAIRWELL IDENTIFICATION MISSING AT EACH FLOOR ON INTERIOR SIDE OF STAIRWELL . UPPER AND LOWER LEVELS OF GARAGE , FLOORS LEVELS NOT MARKED WITH SIGNAGE AND GARAGE ONLY STAIRS MISSING SIGNAGE . | 5701 N SHERIDAN RD | PERIODIC | FAILED | View |
I-A I-B I-C AND II FIRE RESIST | UPPER AND LOWER LEVELS OF PARKING GARAGE - REMOVE ALL WOOD PARTITIONS , WOOD STORAGE UNITS AND SHEDS CONSTRUCTED IN GARAGE AND RETURN TO ORIGINAL STATE OR PROVIDE PLANS AND OBTAIN PERMIT FOR RENOVATION . | 5701 N SHERIDAN RD | PERIODIC | FAILED | View |
PROVIDE | PROVIDE PER SECTION CODE 13-196-204 ONE WAY AND TWO WAY VOICE COMMUNICATION SYSTEMS. ONE WAY AND TWO WAY VOICE COMMUNICATION SYSTEMS , INSTALLATION NOT COMPLETE AT TIME OF LIFE SAFETY INSPECTION . | 5701 N SHERIDAN RD | PERIODIC | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | LOWER LEVEL OF PARKING GARAGE - CONCRETE CEILING ,SPALLED, LOOSE , FLAKING MASONRY COATING , WITH SPALLED AREAS WITH RUSTED AND EXPOSED REBARS . LOOSE PREVIOUS REPAIRS . MASONRY REPAIR PERMIT REQUIRED . | 5701 N SHERIDAN RD | PERIODIC | FAILED | View |
DEBRIS, EXCESSIVE | UPPER AND LOWER LEVELS OF PARKING GARAGE - REMOVE COMBUSTIBLE STORAGE AND EXCESSIVE DEBRIS . | 5701 N SHERIDAN RD | PERIODIC | FAILED | View |
WORK NOT ALLOWED | REMOVE ALL WOOD FRAMED PARTITIONS (SMALL STORAGE ROOM ) INSTALLED AT THE SOUTH CORRIDOR ( ACROSS FROM HAIR SALON WINDOWS ) WITHOUT A PERMIT . | 5701 N SHERIDAN RD | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | CODE DATA TAGS LOCATED ON CONTROLLERS MUST BE FILLED OUT. THEY ARE CURRENTLY BLANK - ELEVATORS | 5701 N SHERIDAN RD | PERIODIC | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | MAINTAIN A CURICUT FIVE SERVICE MONTHLY TEST LOG ON SUTE (PRIVIDED) - ALL EVEVATORS | 5701 N SHERIDAN RD | PERIODIC | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | NORTH TOWER PASSENGER ELEVATORS OD NOT RESPOND TO PHASE 1 COMMAND - REPAIR SAME | 5701 N SHERIDAN RD | PERIODIC | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | REPAIR MALFUNCTIONING DOOR RESTRICTORS ON ELEVATORS 3,4,5,6,7, AND 8 | 5701 N SHERIDAN RD | PERIODIC | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | REPAIR MALFUNCATIONING 2- WAY COMMUNICATION (PHONE) IN ELEVATOR CAB #5 | 5701 N SHERIDAN RD | PERIODIC | PASSED | View |
SELF-CLOSE DOOR >4 STORY RES. | ALL FLOORS - APARTMENT DOORS NOT CLOSING AND LATCHING . | 5701 N SHERIDAN RD | PERIODIC | FAILED | View |
1HR PUB.CORRIDOR IN MULT. D.U. | BASEMENT , FIRST AND SECOND FLOORS , ALL DOORS IN CORRIDORS REQUIRE FIRE RATED DOOR AND SELF CLOSING DEVICES . NORTH AND SOUTH LAUNDRY ROOMS , PUMP ROOM , TENANT STORAGE ROOMS , BIKE STORAGE ROOM ( FULL GLASS DOOR ), SOUTH HAIR SALON , NORTH MINI MART ( FULL GLASS DOOR ) , ELECTRICAL ROOMS , AT & T ROOMS AND EQUIPMENT ROOMS . SECOND FLOOR NORTH AND SOUTH LAUNDRY ROOMS AND FIRST FLOOR HAIR SALON AT SOUTH - LARGE GLASS HALF WALL WINDOWS NOT FIRE RATED . | 5701 N SHERIDAN RD | PERIODIC | FAILED | View |
CLASS B DOOR IN STAIRWELL | SOUTH BASEMENT AND SOUTH FIRST FLOOR STAIRWAY DOORS MISSING FIRE RATED TAGS . | 5701 N SHERIDAN RD | PERIODIC | FAILED | View |
ROACHES | UNIT #16H - DEAD ROACH INSIDE BATHROOM VANITY | 5701 N SHERIDAN RD | COMPLAINT | CLOSED | View |
ARRANGE PREMISE INSPECTION | UNABLE TO INSPECT COMPLETE INTERIOR, STAIRWELLS, APARTMENTS, BASEMENT, AND GARAGE. UNVERIFIED DETECTORS AND CONDITIONS. | 5701 N SHERIDAN RD | COMPLAINT | FAILED | View |
REPAIR ROOF | LOBBY ROOF/SOUTHWEST CORNER - CHIPPED OFF SECTION OF CONCRETE SLAB, WITH EXPOSED AND RUSTING RE-BARS.SOUTH TOWER/1ST FLOOR ROOF/SOUTH ELEVATION - CHIPPED OFF SECTIONS OF CONCRETE SLAB, WITH EXPOSED AND RUSTING RE-BARS. NORTH TOWER/1ST FLOOR ROOF/NORTH ELEVATION - CHIPPED OFF SECTIONS OF CONCRETE SLAB, WITH EXPOSED AND RUSTING RE-BARS. | 5701 N SHERIDAN RD | COMPLAINT | FAILED | View |
STRUCTURAL MEMBER, PIER BLOCK | NORTH TOWER/SOUTHWEST CORNER AND NORTH ELEVATION/3RD FLOOR CONCRETE SLABS - CHIPPED-OFF SECTIONS OF CONCRETE, WITH EXPOSED AND RUSTING RE-BARS.SOUTH TOWER/SOUTH ELEVATION/3RD FLOOR CONCRETE SLAB - CHIPPED-OFF SECTIONS OF CONCRETE, WITH EXPOSED AND RUSTING RE-BARS. | 5701 N SHERIDAN RD | COMPLAINT | FAILED | View |
REPAIR FENCE | NORTHWEST CORNER/PARKING LOT CONCRETE FENCE - SOUTHERN CONCRETE PANEL OUT OF PLUMB AND LEANING DUE WEST. | 5701 N SHERIDAN RD | COMPLAINT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ALL ELEVATORS: PERFORM CATEGORY 5 TEST. TAG AND DOCUMENT AS REQUIRED. | 5701 N SHERIDAN RD | PERIODIC | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | BASEMENT PARKING GARAGE -EXIT DOORS AT NORTH AND SOUTH ARE LOCKED AND REQUIRE A KEY TO EXIT INTO BUILDING AT EGRESS SIDE . NO FAIL SAFE INSTALLED . | 5701 N SHERIDAN RD | PERIODIC | FAILED | View |
PROVIDE | PROVIDE PER SECTION CODE 18-27-700.6 EMERGENCY LIGHTING . EMERGENCY LIGHTING MISSING IN NORTH BASEMENT BOILER / PUMP ROOMS . ELECTRICAL PERMIT REQUIRED . | 5701 N SHERIDAN RD | PERIODIC | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | INTERIOR OF BUILDING MOST APARTMENTS NO RESPONSE. UNVERIFIED DETECTORS AND CONDITIONS. UNVERIFIED COMPLAINT OF APT. 4T - MICE. | 5701 N SHERIDAN RD | PERIODIC | PASSED | View |