REPAIR PORCH SYSTEM | REAR PORCH SYSTEM WITH THE FOLLOWING DEFECTS/DEFICIENT CONDITIONS (1) LANDING AND FLIGHT OF STAIRS INCLUDING DECKS WAY OUT OF LEVEL DUE TO FOOTING FAILURE. (2) COLUMNS EXPOSED SECTIONS) WITH BUTT JOINTS (3)STRINGER CONNECTIONS NOT BOLTED, SOME SCABBING TO SHORE-UP SECTIONS. TREADS WORN/ROTTED. (4) BEAM CONNECTION AT FIRE OUT SPREADING AND WITHOUT TIE STRAPS (5) PLANS/PERMITS REQUIRED. | 1434 S KOSTNER AVE | PERIODIC | FAILED | View |
1-HR STAIR ENCLOSURE, <3 STORY | REAR PORCH SYSTEM ENCLOSED, SEE EXPOSED WALL FRAMING AT FLIGHT OF STAIRS, PARTITIONS ERECTED TO SEPARATE DECK FROM STAIRS IS 1/2" DRY WALL, INTERIOR DOOR/ FRAME. | 1434 S KOSTNER AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | WEST-STAIRS FROM GRADE TO 1ST FL IMPROPERLY CONSTRUCTED (1) 4X4 SITTING ON TOP OF WOOD STUBS, NOT ANCHORED (2) STRINGERS OVER CUT AT TREAD. (3) JOISTS NOT ANCHORED AT POSTS/WALL. (4) PERMIT REQUIRED. | 1434 S KOSTNER AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | EAST AND WEST-NEWLY POURED CONCRETE STEPS AND RETAINING WALLS WITHOUT GUARD RAILS AND HAND RAILS. | 1434 S KOSTNER AVE | PERIODIC | FAILED | View |
1-HR HEATING PLANT SEPARATION | EAST AND WEST-NEWLY POURED CONCRETE STEPS AND RETAINING WALLS WITHOUT GUARD RAILS AND HAND RAILS. | 1434 S KOSTNER AVE | PERIODIC | FAILED | View |
HEATING PLANT/BOILER ROOM DOOR | BOILER RM - MISSING RATED DOOR /FRAME ASSEMBLY. | 1434 S KOSTNER AVE | PERIODIC | FAILED | View |
CARB MONOX DETECT IN RESID | BOILER RM-MISSING CARBON MONOXIDE DETECTOR. | 1434 S KOSTNER AVE | PERIODIC | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | 6FT WOOD/IRON FENCE ERECTED WITH-OUT PERMIT. | 1434 S KOSTNER AVE | PERIODIC | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | ALL LEVELS OF INTERIOR LIVING AREA-REPAIR DAMAGE WALLS/CEILINGS, MOST APPARENT IN KITCHEN AND BATHS (2) DAMAGED ACOUSTICAL PANEL CEILINGS (3) INTERIOR STAIRWELL | 1434 S KOSTNER AVE | PERIODIC | FAILED | View |
SCAVENGER SERVICE | REMOVE JUNK AND DEBRIS - FRONT YARD, PORCH LANDINGS AND REAR BSMT. AREA. | 1434 S KOSTNER AVE | PERIODIC | FAILED | View |
REPAIR FLOOR | REPAIR FLOOR FINISH - 1ST FL APT. | 1434 S KOSTNER AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR, RESET | REPLACE/REPAIR DAMAGED ENTRY DOORS - 1ST FL REARS, 2ND FL. | 1434 S KOSTNER AVE | PERIODIC | FAILED | View |
ARRANGE PERMIT INSP. | 1434 S KOSTNER AVE | PERMIT | PASSED | View | |
REPLCE WINDOW PANES, PLEXGLAS | 3RD FL. KITCHEN WINDOW FACING PORCH - BROKEN PANES. | 1434 S KOSTNER AVE | PERIODIC | FAILED | View |