The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
| Violation | Inspector Comments | Address | Category | Status | View |
|---|---|---|---|---|---|
| ARRANGE FOR REINSPECTION REGAR | INTERIOR OF BUILDING - NO RESPONSE, UNVERIFIED DETECTORS OCCUPANCY AND CONDITIONS.- UNABLE TO GAIN ENTRY, FRONT AND REAR SECURITY DOOR, UNABLE TO PERFORM 2016 ANNUAL INSPECTION. | 1657 W HURON ST | PERIODIC | FAILED | View |
| POST OWNER/MANAGERS NAME/# | MISSING OWNER¿S INFORMATION. | 1657 W HURON ST | PERIODIC | FAILED | View |
| REPAIR PORCH SYSTEM | 3 STORY WOOD PORCH, - SOUTH ELEVATION, - COLUMNS ERECTED ON TOP OF CONCRETE SLAB, WITH NO BASES, FOUNDATION STATUS UNKNOWN.- COLUMNS HAVE INADEQUATE HALF - LAP JOINTS FASTENED WITH ( 2 ) ½¿ BOLTS ONLY SPLICE IS LESS THE 18¿, 4X4 COLUMNS HAVE INADEQUATE HALF-LAP JOINTS FASTENED WITH NAILS ONLY, LEDGER BEAMS FASTENED TO BUILDING EXTERIOR WALLS WITH NAILS ONLY, - CONNECTIONS THROUGHOUT THE ENTIRE PORCH INCLUDING AT ROOF LINE ARE MADE WITH COMMON NAILS; THROUGHOUT PORCH MISSING STEEL ANGLE BRACKETS, - LEDGER BEAMS ARE NOT ATTACHED TO MASONRY AT ALL FLOORS. - AT 2ND AND 3RD FLOORS TWO PORTIONS OF THE PORCH CANTILIVER WITH 2X8'S ATTACHED WITH PRE-ENGINEER BRACKETS, THOSE CONNECTIONS ARE VERY WEAK AND CONNECTED TO OTHER MEMBERS WITH NAIL PLATES.PLANS AND PERMIT ARE REQUIRED TO REPAIR PORCH. | 1657 W HURON ST | PERIODIC | FAILED | View |
| REPAIR PORCH SYSTEM | (1) NO FOOTINGS COLUMNS NOT SECURE (2) NO BOLTS ON STRINGERS, WORN (3) NO BOLTS OR STRAPS ON BEAM TO COLUMN CONNECTIONS (4) NO JOIST HANGERS, WORN (5) NO BOLTS ON LEDGER BOARDS (6) CANTERLEVERED DECK NOT PROPERLY SUPPORTED BRACING/KICKERS NOT BOLTED PROPERLY MISSING BOLTS (7) BEAMS MISSING STRAPS IN POCKETS (8) NO BLOCKING BETWEEN JOIST (9) GUARDRAILS NOT PROPERLY SECURE TO BUILDING OR COLUMNS WORN (10) COLUMNS TWISTING AT VARIOUS LOCATIONS (11) TOP OF GUARDRAILS LOOSE (12) PICKETS AT THIRD LEVEL DAMAGED ALL WORN (13) TREADS WORN, LOOSE (14) PORCH IS 4 STORIES TOP OF DECK IS ON ROOF OF BUILDING (15) REMOVE OBSTRUCTION OF GATE BETWEEN SECOND AND THIRD FLOOR | 1657 W HURON ST | PERIODIC | FAILED | View |
| PLANS & PERMITS REQ - CONTRCTR | ADDITIONAL INFORMATION: SUBMIT PLANS FOR,PORCH DECK | 1657 W HURON ST | PERIODIC | FAILED | View |
| REPAIR EXTERIOR WALL | ADDITIONAL INFORMATION: EXTERIOR WALL,MORTAR WASHED OUT | 1657 W HURON ST | PERIODIC | FAILED | View |
| SUBMIT 2 COPY STRUCTURAL RPT | ADDITIONAL INFORMATION: STRUCTURAL REPORT,ROOF DECKCOMMENTS: ROOF MUST SUPPORT ROOF DECK BUT PORCH CANNOT BE CONNECTED TO PORCH | 1657 W HURON ST | PERIODIC | FAILED | View |
| PROVIDE GUARD RAIL 42 IN HIGH | ADDITIONAL INFORMATION: GUARDRAIL 3 FEET HIGH,MISSINGCOMMENTS: HANDRAIL | 1657 W HURON ST | PERIODIC | FAILED | View |
| PROVIDE | PROVIDE PERMIT FOR REAR 12' ELECTROMECHANIC FENCE, NO PERMIT ON FILE FOR ELECTRIC FENCE. | 1657 W HURON ST | PERIODIC | FAILED | View |