Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR EAVES | WEST ELEVATIONS - ROOF EAVES ROTTING. | 3016 N HOYNE AVE | COMPLAINT | PASSED | View |
MAINTAIN WINDOW | EAST ELEVATION, 1ST FLOOR - STORM WINDOW NOT SECURED. 2ND FLOOR STORM WINDOW MISSING SASH, GLASS LOOSE. | 3016 N HOYNE AVE | COMPLAINT | PASSED | View |
SCREEN OUTER DOORS, WINDOWS | EAST ELEVATION, 2ND FLOOR - MISSING WINDOW SCREEN. | 3016 N HOYNE AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR STAIR | EAST ELEVATION, FRONT EXTERIOR STAIRS FROM GRADE TO 1ST FLOOR - 2X6 LEDGER BOARD NAILED ONLY. SINGLE 2X6 BEAMS WEAK AND SAGGING. ENTIRE DECK SAGGING. RAILINGS ONLY 34 INCHES HIGH WITH 13 1/2 INCH GAPS BETWEEN RAILS. | 3016 N HOYNE AVE | COMPLAINT | PASSED | View |
REPLACE D&H PORCH | WEST ELEVATION, REAR 3 STORY OPEN WOOD PORCH SYSTEM - COLUMNS OVER NOTCHED AT 4X6 BEAM CONNECTIONS. END OF BEAM ROTTING. CENTER COLUMN ROTTING. NORTH COLUMN HALF LAP JOINT UNDERSIZED AT ONLY 8 INCHES. 2ND FLOOR BEAMS ROTTING AND PULLING FROM COLUMN BEAM SEATS. 2X8 LEDGER BOARDS NAILED ONLY. ENTIRE 1ST AND 2ND FLOOR DECKS ROTTING, SAGGING AND WEAK. RIM JOIST AND STRINGERS SCABBED AND ROTTING. RAILINGS HAVE WEAK PULLING CONNECTIONS. MOST RAILINGS ONLY 36 INCHES HIGH SOME WITH GAPS OF 16 INCHES BETWEEN RAILS. PLANS AND PERMIT REQUIRED TO REPLACE EXTERIOR PORCH. | 3016 N HOYNE AVE | COMPLAINT | PASSED | View |