The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
MAINTAIN OR REPAIR HYDRO ELEVA | FINISH FLOOR IN CAB. | 1438 W CORTLAND ST | PERMIT | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | INSTALL LOW OVERHEAD SIGN ON TOP OF CAR. | 1438 W CORTLAND ST | PERMIT | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | 1ST & 2ND FLOOR FINISH FLOOR IN FRONT OF ELEVATOR. | 1438 W CORTLAND ST | PERMIT | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | MOUNT FIRE EXTINGUSHER UPDATED AND TAGED BY STRIKE MACHINE ROOM DOOR. | 1438 W CORTLAND ST | PERMIT | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | BLOCK IN VENT TOP OF HOISTWAY. | 1438 W CORTLAND ST | PERMIT | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | PERMENATLY LABEL DISCONNECTS CAB LIGHT MAINLINE WHERE FEED FROM ETC.. | 1438 W CORTLAND ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | INSTALL IN CASE OF FIRE SIGNS. | 1438 W CORTLAND ST | PERMIT | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | INSTALL COVER ON DUCT TOP OF HOISTWAY. | 1438 W CORTLAND ST | PERMIT | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | ADJUST DOOR RESTRICTOR TOP OF HOISTWAY. | 1438 W CORTLAND ST | PERMIT | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | ADJUST DOOR RESTRICTOR WEST DOOR. | 1438 W CORTLAND ST | PERMIT | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | INSTALL SUMP PUMP AND COVER ACORDING TO CITY OF CHICAGO PLUMBING CODE. | 1438 W CORTLAND ST | PERMIT | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | INSTAL SINGLE GANG NON GFI OUTLET IN PIT FOR SUMP PUMP. | 1438 W CORTLAND ST | PERMIT | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | PROVIDE GFI OUTLET IN PIT. | 1438 W CORTLAND ST | PERMIT | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | INSTALL HOSES AND PIT CANS IN PIT. | 1438 W CORTLAND ST | PERMIT | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | INSTALL WORKING PHONE24 HOUR 2 WAY COMMUNICATION. | 1438 W CORTLAND ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | PATCH HOLE IN BLOCK BRICK 1ST FLOOR. | 1438 W CORTLAND ST | PERMIT | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | INSTALL MACHINE ROOM DOOR 2 HOUR FIRE RATED WITH CLOSER. | 1438 W CORTLAND ST | PERMIT | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | PROVIDE PERMANET MAXCHINE ROOM DOOR SIGN. | 1438 W CORTLAND ST | PERMIT | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | INSTALL CITY OF CHICAGO FIRE SERVICE KEY BOX BY PHASE ONE SWITCH. | 1438 W CORTLAND ST | PERMIT | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | INSTALL LIGHT 1ST FLOOR ELEVATOR LOBBY. | 1438 W CORTLAND ST | PERMIT | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | PROVIDE VENTILATION MACHINE ROOM. | 1438 W CORTLAND ST | PERMIT | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | INSTALL GUARD ON LIGHT MACHINE ROOM. | 1438 W CORTLAND ST | PERMIT | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | FIRE SERVICE PHASE 2 REAR BUTTONS TO OPERATE REAR DOOR ONLY CLOSE AND OPEN.SAME FOR 1ST FLOOR PH2OPEN AND CLOSE BUTTONS TO OPERATE FRONT DOOR ONLY. | 1438 W CORTLAND ST | PERMIT | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | INSTALL ALL COVERS TOP OF DAR HOISTWAY. | 1438 W CORTLAND ST | PERMIT | PASSED | View |
REPAIR ROOF | ROOF-10 PALLETS OF CONCRETE BLOCK STORED ON FLAT ROOF. | 1438 W CORTLAND ST | COMPLAINT | FAILED | View |
SUBMIT 2 COPY STRUCTURAL RPT | BUILDING ROOF-10 PALLETS OF CONCRETE BLOCK BEING STORED ON FLAT ROOF-CONCENTRATED LOAD;SUBMIT STRUCTURAL ENGINEERS REPORT ON STABILITY OF ROOF STRUCTURE. | 1438 W CORTLAND ST | COMPLAINT | FAILED | View |
EXPOSED WIRING | WEST ELEVATION / 2ND FLOOR EXTERIOR LIGHT FIXTURES-EXPOSED WIRES. | 1438 W CORTLAND ST | COMPLAINT | FAILED | View |
DEMO DEBRIS | WEST LOT- USED LUMBER,ELECTRIC LIGHT FIXTURES. | 1438 W CORTLAND ST | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | WEST ELEVATION,JUNK AND REFUSE ACCUMILATING. | 1438 W CORTLAND ST | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | NORTHWEST ELEVATION / ACCUMULATION OF JUNK AND REFUSE BLOCKING FIRE ESCAPE AND 1ST FLOOR EXIT DOOR OF ADJACENT PROPERTY AT 1907 N.MENDELL ST. | 1438 W CORTLAND ST | COMPLAINT | FAILED | View |
REPAIR ROOF | ROOF-10 PALLETS OF CONCRETE BLOCK STORED ON FLAT ROOF. | 1438 W CORTLAND ST | COMPLAINT | CLOSED | View |
SUBMIT 2 COPY STRUCTURAL RPT | BUILDING ROOF-10 PALLETS OF CONCRETE BLOCK BEING STORED ON FLAT ROOF-CONCENTRATED LOAD;SUBMIT STRUCTURAL ENGINEERS REPORT ON STABILITY OF ROOF STRUCTURE. | 1438 W CORTLAND ST | COMPLAINT | CLOSED | View |
EXPOSED WIRING | WEST ELEVATION / 2ND FLOOR EXTERIOR LIGHT FIXTURES-EXPOSED WIRES. | 1438 W CORTLAND ST | COMPLAINT | CLOSED | View |
DEMO DEBRIS | WEST LOT- USED LUMBER,ELECTRIC LIGHT FIXTURES. | 1438 W CORTLAND ST | COMPLAINT | CLOSED | View |
DEBRIS, EXCESSIVE | WEST ELEVATION,JUNK AND REFUSE ACCUMILATING. | 1438 W CORTLAND ST | COMPLAINT | CLOSED | View |
OBSTRUCTIONS IN EXIT WAY | NORTHWEST ELEVATION / ACCUMULATION OF JUNK AND REFUSE BLOCKING FIRE ESCAPE AND 1ST FLOOR EXIT DOOR OF ADJACENT PROPERTY AT 1907 N.MENDELL ST. | 1438 W CORTLAND ST | COMPLAINT | CLOSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | PROVIDE TEMPERATURE CONTROL MACHINE ROOM. | 1438 W CORTLAND ST | PERMIT | PASSED | View |