The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
HEAT UNIT ADEQUATELY | APT. 1: 65 DEGREES F, HEATING SYSTEM OFF DURING TIME OF INSPECTION, 1:26 PM | 3103 W 25TH ST | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | APT. 1: NO CARBON MONOXIDE DETECTOR DURING TIME OF INSPECTION , 1:26 PM | 3103 W 25TH ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | NORTH ELEVATION 1 STORY PORCH SYSTEM DOESN'T MEET CITY CODE FOR 100 LBS PER SQ. FT. UNDERSIZED JOISTS, UPRIGHTS, IMPROPER BEAM POCKET CONNECTIONS, IMPROPERLY CUT STRINGERS. NO FOOTING. | 3103 W 25TH ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | OBTAIN PLANS AND PERMITS BEFORE STARTING WORK. | 3103 W 25TH ST | COMPLAINT | FAILED | View |
ROACHES | 2ND FLOOR KITCHEN ROACHES OBSERVED. | 3103 W 25TH ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | POST OWNER OR MANAGEMENT ON FRONT OF BUILDING ON A SIGN WITH PHONE NUMBER. | 3103 W 25TH ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | MISSING SMOKE DETECTOR. | 3103 W 25TH ST | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | MISSING CARBON DETECTOR. | 3103 W 25TH ST | COMPLAINT | FAILED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | GAS SERVICE-SHUT OFF, HOT WATER PROVIDED AT 52F. | 3103 W 25TH ST | COMPLAINT | FAILED | View |
PROVIDE | PROVIDE ONE FURNACE FOR EACH RESIDENCE PER CODE (18-28-918.9.1 | 3103 W 25TH ST | COMPLAINT | FAILED | View |
ARRANGE COMPLETED PERMIT INSP. | 3103 W 25TH ST | COMPLAINT | FAILED | View | |
SUBMIT PLANS/GET VENT PERMIT | 3103 W 25TH ST | COMPLAINT | FAILED | View | |
REPAIR PORCH SYSTEM | NORTH ELEVATION 2 STORY WOOD PORCH 4X4 COLUMNS ARE SITTING ON DIRT AND CONCRETE SLABS,FOUNDATIONS UNKNOWN,TOP AND BOTTOM GUARDRAILS ARE ONLY TOENAILED TO COLUMNS WITH SOME BROKEN AND MISSING PICKETS,2X6 JOIST ARE SPANNING OVER 8FT,TREADS ARE ONLY 91/4 " IN DEPTH SUBMIT PLANS AND OBTAIN PERMIT BEFORE REPAIRING OR REPLACING PORCH. | 3103 W 25TH ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNER I.D SIGN POSTED. | 3103 W 25TH ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | UNABLE TO GAIN ENTRY TO VERIFY OCCUPANCY,DETECTORS ANMD COMPLAINT OF BROKEN WALLS AND FLOORS AND RATS. | 3103 W 25TH ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNER I.D SIGN POSTED. | 3103 W 25TH ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | NORTH ELEVATION 2 STORY WOOD PORCH HAS 4X4 COLUMNS BEING SUPPORTED BY THE GROUND AND CONCRETE SLAB.ALL CONNECTIONS ARE FASTENED WITH NAILS.STINGERS ARE OVERCUT.TREADS ARE 91/4" IN DEPTH.JOIST ARE SPANNING OVER 8FT.GUARD AND HANDRAILS ARE VERY UNSTABLE.SUBMIT PLAN AND OBTAIN PERMIT TO REPAIR PORCH.SOUTH ELEVATION BACK STAIRS HANDRAILS ARE UNDER 30" HIGH AND GUARDRAILS ARE 32" HIGH.PICKETS ARE 10" ON CENTER.OBTAIN PERMIT FOR REPAIRS. | 3103 W 25TH ST | COMPLAINT | FAILED | View |
PROVIDE GUTTER & DOWNSPOUT | EAST ELEVATION SECTIOS OF DOWNSPOUTS MISSING. | 3103 W 25TH ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO RESPONSE/ENTRY TO VERIFY OCCUPANCY AND DETECTORS.UNABLE TO GAIN ENTRY TO VERIFY COMPLAINT OF ROOF LEAKING AND SQUIRRELS IN HOUSE. | 3103 W 25TH ST | COMPLAINT | FAILED | View |
VACANT BUILDING - REGISTER | 3103 W 25TH ST | COMPLAINT | CLOSED | View | |
MORTGAGEES REGISTER VACANT BLD | 3103 W 25TH ST | COMPLAINT | CLOSED | View | |
MORTGAGEES MUST BOARD VACANT | 3103 W 25TH ST | COMPLAINT | CLOSED | View | |
MAINTAN BLDG IN SAFE CONDITION | 3103 W 25TH ST | COMPLAINT | CLOSED | View | |
WATCHMAN | 3103 W 25TH ST | COMPLAINT | CLOSED | View | |
VACANT BUILDING - REGISTER | 3103 W 25TH ST | COMPLAINT | CLOSED | View | |
POST OWNER INFO ON ABDN BLDG | 3103 W 25TH ST | COMPLAINT | CLOSED | View | |
REPAIR EXTERIOR STAIR | SOUTH ELEVATION STAIR SYSTEM DOESN'T MEET CITY CODE UNDERSIZED HANDRAILS IMPROPER BEAM POCKET CONNECTIONS, IMPROPERLY CUT STRINGER. | 3103 W 25TH ST | COMPLAINT | FAILED | View |
REPAIR GUTTER & DOWNSPOUT | EAST ELEVATION SECTIONS OF DOENSPOUTS MISSING. | 3103 W 25TH ST | COMPLAINT | FAILED | View |
REPAIR/WRECK DANGER RESID PREM | 3103 W 25TH ST | COMPLAINT | CLOSED | View | |
OBTAIN OR POST PERMIT | 3103 W 25TH ST | COMPLAINT | CLOSED | View |