| FLAKY INTERIOR PAINT | PEELING LOOSE PAINT - WINDOWS, ALL EXPOSED WOOD TRIM | 6225 S SEELEY AVE | COMPLAINT | FAILED | View |
| REPAIR EXTERIOR DOOR | FRONT DOOR - DAMAGED STEEL PANEL - BENT, PEELING OF DOOR | 6225 S SEELEY AVE | COMPLAINT | FAILED | View |
| REPAIR EXTERIOR DOOR HARDWARE | FRONT DOOR - MISSING LOCK | 6225 S SEELEY AVE | COMPLAINT | FAILED | View |
| REPAIR EXTERIOR WALL | OPEN JOINTS - WASHED OUT MORTAR - WEST ELEVATION/LOOSE SIDING REAR. | 6225 S SEELEY AVE | COMPLAINT | FAILED | View |
| SERVICE WALK, PASSAGE, AREAWAY | BROKEN SERVICE WALK FRONT & SOUTH REAR | 6225 S SEELEY AVE | COMPLAINT | FAILED | View |
| REPAIR EXTERIOR STAIR | FRONT STAIR - PLATFORM CRACK, OPEN JOINT - EXCESSIVE. | 6225 S SEELEY AVE | COMPLAINT | FAILED | View |
| POST OWNER/MANAGERS NAME/# | NO MANAGEMENT SIGN POSTED | 6225 S SEELEY AVE | COMPLAINT | FAILED | View |
| PARAPET & COPING | PARAPET - LOOSE MORTAR/MISSING BROKEN COPING - NORTH - SOUTH | 6225 S SEELEY AVE | COMPLAINT | FAILED | View |
| REPAIR PORCH SYSTEM | REAR - 2 STORY PORCH/IMPROPER FOOTINGS/LOOKOUT DISCONNECTED GROUND LEVEL/NO STEEL STRAPS, ANGEL STEEL PLATES/NO BOLTS, NO JOIST HANGERS/GUARDRAILS IMPROPER HEIGHT, MISSING PICKETS. WORN SPLIT TREADS, COLUMN SPLICE NOT BOLTED. (NO PLANS REQUIRED - PERMIT ONLY - REPAIR) | 6225 S SEELEY AVE | COMPLAINT | FAILED | View |
| REPLCE WINDOW PANES, PLEXGLAS | 1ST FLOOR FRONT - BROKEN PANE | 6225 S SEELEY AVE | COMPLAINT | FAILED | View |
| REPAIR/REBUILD GARAGE OR SHED | GARAGE - ROTTED EAVES, ROTTED ROOF, RUSTED OVERHEAD DOOR | 6225 S SEELEY AVE | COMPLAINT | FAILED | View |
| ARRANGE PREMISE INSPECTION | NO INTERIOR ENTRY - PER COMPLAINT | 6225 S SEELEY AVE | COMPLAINT | FAILED | View |
| PLANS & PERMITS REQ - CONTRCTR | REMOVING REAR ENCLOSED PORCH. | 6225 S SEELEY AVE | COMPLAINT | FAILED | View |
| BLANK-TEXT MUST CITE CODE SECT | STOP ALL WORK ON PREMISES UNTIL PLANS ARE APPROVED AND PERMIT IS OBTAINEDSECTION 12-080, 13-32-035. | 6225 S SEELEY AVE | COMPLAINT | FAILED | View |
| CHIMNEY | CHIMNEY -WASHED OUT MORTAR. | 6225 S SEELEY AVE | COMPLAINT | FAILED | View |
| MAINTAIN WINDOW | NORTH WINDOWS - PEELING PAINT. | 6225 S SEELEY AVE | COMPLAINT | FAILED | View |
| REPAIR EXTERIOR WALL | NORTH, SOUTH AND WEST EXTERIOR WALLS - WASHED OUT MORTAR.SOUTH ELEVATION - STEP CRACK (1ST FLOOR). | 6225 S SEELEY AVE | COMPLAINT | FAILED | View |
| REPLACE D&H PORCH | REAR 2 STORY PARTIALLY ENCLOSED WOOD PORCH: COLUMNS ERTECTED ON TOP OF CONCRETE BASES; FOUNDATION STATUS UNKNOWN.; CENTER COLUMN IS ROTTED AT GRADE.; RIM JOIST, STRINGERS AND RAILINGS ARE FASTENED WITH NAILS ONLY.; GUARDRAILS ARE ONLY 36" HIGH.; GUARDRAIL END POST TO WALL ARE FASTENED WITH NAILS ONLY.; RAILINGS MISSING PICKETS.; TREADS ARE ONLY 9-1/2" WIDE.; COLUMNS HALF-LAP CONNECTIONS ARE FASTENED WITH NAILS ONLY.; PORCH AND 1ST FLOOR RIM JOIST ARE DEFLECTING.; PORCH IS IN D&H CONDITION.PLANS AND PERMIT ARE REQUIRED TO REPAIR OR REPLACE D&H PORCH. | 6225 S SEELEY AVE | COMPLAINT | FAILED | View |
| ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - ENTRY REFUSED, UNABLE TO VERIFY DETECTORS AND INTERIOR CONDITIONS. | 6225 S SEELEY AVE | COMPLAINT | FAILED | View |
| PARAPET | NORTH, SOUTH AND WEST PARAPET WALLS - WASHED OUT MORTAR. | 6225 S SEELEY AVE | COMPLAINT | FAILED | View |
| PROVID SELF CLSING SCREEN DVCE | FRONT - SCREEN DOOR - MISSING CLOSER | 6225 S SEELEY AVE | COMPLAINT | FAILED | View |
| REPAIR OR REPLACE | GARAGE - ROTTED EAVES, ROTTED ROOF, RUSTED OVERHEAD DOOR | 6225 S SEELEY AVE | COMPLAINT | FAILED | View |