The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR FENCE | FRONT GATE BROKE. RUSTED OUT BOTTOM RAIL. | 7419 S INGLESIDE AVE | COMPLAINT | FAILED | View |
PARAPET | PARAPET HAS OPEN MORTAR JOINT AND SPALLING BRICKS NORTH AND SOUTH. | 7419 S INGLESIDE AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | WINDOW BROKEN: BASEMENT NORTH ELEVATION. | 7419 S INGLESIDE AVE | COMPLAINT | CLOSED | View |
PROVIDE GUARD RAIL 42 IN HIGH | GUARDRAIL MISSING AROUND DROP OFF TO BASEMENT REAR, ALSO AT STAIR. | 7419 S INGLESIDE AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH: 6X6 COLUMNS RESTING ON CEMENT PADS. RAILS AT STAIRS ARE HORIZONTAL. MISSING JOIST HANGERS AT LANDING. RAIL HEIGHT IS 36". STRINGERS NOT BOLTED. DECK BOARDS WARPED AND CRACKING AT LANDING. RAILS SECURED TO 6X6 AND 4X4'S WITH NAIL ARE INADEQUATE DUE TO WOOD TWISTING AND BOWING CAUSING GAPS AT CONNECTION ON POINTS. RAILS LOOSE GRADE TO 1ST. HANDRAIL BROKEN GRADE TO BASEMENT. | 7419 S INGLESIDE AVE | COMPLAINT | FAILED | View |
ABANDONED REFRIGERATOR | REFRIGERATION ON BACK PORCH 2ND FLR. | 7419 S INGLESIDE AVE | COMPLAINT | CLOSED | View |
REPAIR COPING | COPING - LOOSE TILES, WITH OPEN MORTAR JOINTS. | 7419 S INGLESIDE AVE | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE FAUCET | APT. 1 / BATHROOM - TUB FAUCET LOOSE AND LEAKING. | 7419 S INGLESIDE AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | APT. 1 / BATHROOM CEILING AND WALLS - HOLES, WITH WATER DAMAGE. | 7419 S INGLESIDE AVE | COMPLAINT | FAILED | View |
INT WALL/CEILING CHIP PLASTER | BROKEN CEILING PLASTER. | 7419 S INGLESIDE AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | FURNACE AREA - MISSING SMOKE DETECTOR. | 7419 S INGLESIDE AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | FURNACE AREA - MISSING CARBON MONOXIDE DETECTOR. | 7419 S INGLESIDE AVE | COMPLAINT | FAILED | View |
REPAIR FLOOR | SEWAGE PIPE - BROKEN CONCRETE AT BASE. | 7419 S INGLESIDE AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | 2-STORY / REAR PORCH: GUARDRAIL SECTION ONLY 36 INCHES HIGH, LOOSE AND PULLING AT 2. RAILING SECTIONS ARE OF "LADDER" TYPE, WITH HORIZONTAL TIES SPACED 8 INCHES APART. 6X6 COLUMNS ERECTED ON TOP OF UNEVEN, LOOSE AND OUT OF PLUMB CEMENT-CONCRETE PADS WITHOUT BASES - FOUNDATION STATUS UNKNOWN. 2X8 LANDING JOISTS ONLY TOE-NAILED TO EDGE BEAMS. STRINGERS MISSING BOLTS AT WALLS. LANDING DECK BOARDS WRAPED AND CRACKED. RAILING SECTIONS ONLY TOE-NAILED TO 4X4 AND 6X6 COLUMNS, WITH GRADE TO 1AND BASEMENT TO GRADE RAILINGS LOOSE AND BROKEN. PLANS AND PERMIT REQUIRED TO REPAIR REAR PORCH. | 7419 S INGLESIDE AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | REAR BASEMENT TO GRADE STAIRWAY - BROKEN CONCRETE TREADS, WITH MISSING HANDRAIL. | 7419 S INGLESIDE AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW SASH | 1-2ND FLOOR - WINDOW SASHES BROKEN AND ROTTING. | 7419 S INGLESIDE AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | APT. 2 - NO RESPONSE - UNVERIFIED DETECTORS AND CONDITIONS. | 7419 S INGLESIDE AVE | COMPLAINT | FAILED | View |
PARAPET | PARAPET WALLS - SPALLING BRICKS, WITH OPEN MORTAR JOINTS. | 7419 S INGLESIDE AVE | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | REAR BASEMENT STAIRWAY - GUARDRAIL SECTIONS MISSING AT GRADE. | 7419 S INGLESIDE AVE | COMPLAINT | FAILED | View |
DEFECTIVE OUTLETS | APT. 1 / LIVING ROOM, DINING AND BEDROOM - OUTLETS SPARKING AND OUT OF SERVICE. | 7419 S INGLESIDE AVE | COMPLAINT | FAILED | View |