Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-08-30 @ 5:22 PM
PIN: 20261260060000
Property Address: 7419 S INGLESIDE AVE
City - Zip: CHICAGO - 60619
2023 Property Class: 211
2023 Township: 70 - Hyde Park
2023 Neighborhood: 70070
2023 Tax District: 70001
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 20 Violations
Violation Inspector Comments Address Category Status View
REPAIR FENCE FRONT GATE BROKE. RUSTED OUT BOTTOM RAIL. 7419 S INGLESIDE AVE COMPLAINT FAILED View
PARAPET PARAPET HAS OPEN MORTAR JOINT AND SPALLING BRICKS NORTH AND SOUTH. 7419 S INGLESIDE AVE COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS WINDOW BROKEN: BASEMENT NORTH ELEVATION. 7419 S INGLESIDE AVE COMPLAINT CLOSED View
PROVIDE GUARD RAIL 42 IN HIGH GUARDRAIL MISSING AROUND DROP OFF TO BASEMENT REAR, ALSO AT STAIR. 7419 S INGLESIDE AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM REAR PORCH: 6X6 COLUMNS RESTING ON CEMENT PADS. RAILS AT STAIRS ARE HORIZONTAL. MISSING JOIST HANGERS AT LANDING. RAIL HEIGHT IS 36". STRINGERS NOT BOLTED. DECK BOARDS WARPED AND CRACKING AT LANDING. RAILS SECURED TO 6X6 AND 4X4'S WITH NAIL ARE INADEQUATE DUE TO WOOD TWISTING AND BOWING CAUSING GAPS AT CONNECTION ON POINTS. RAILS LOOSE GRADE TO 1ST. HANDRAIL BROKEN GRADE TO BASEMENT. 7419 S INGLESIDE AVE COMPLAINT FAILED View
ABANDONED REFRIGERATOR REFRIGERATION ON BACK PORCH 2ND FLR. 7419 S INGLESIDE AVE COMPLAINT CLOSED View
REPAIR COPING COPING - LOOSE TILES, WITH OPEN MORTAR JOINTS. 7419 S INGLESIDE AVE COMPLAINT FAILED View
REPLACE DEFECTIVE FAUCET APT. 1 / BATHROOM - TUB FAUCET LOOSE AND LEAKING. 7419 S INGLESIDE AVE COMPLAINT FAILED View
REPAIR INTERIOR WALLS/CEILING APT. 1 / BATHROOM CEILING AND WALLS - HOLES, WITH WATER DAMAGE. 7419 S INGLESIDE AVE COMPLAINT FAILED View
INT WALL/CEILING CHIP PLASTER BROKEN CEILING PLASTER. 7419 S INGLESIDE AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS FURNACE AREA - MISSING SMOKE DETECTOR. 7419 S INGLESIDE AVE COMPLAINT FAILED View
CARB MONOX DETECT IN RESID FURNACE AREA - MISSING CARBON MONOXIDE DETECTOR. 7419 S INGLESIDE AVE COMPLAINT FAILED View
REPAIR FLOOR SEWAGE PIPE - BROKEN CONCRETE AT BASE. 7419 S INGLESIDE AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM 2-STORY / REAR PORCH: GUARDRAIL SECTION ONLY 36 INCHES HIGH, LOOSE AND PULLING AT 2. RAILING SECTIONS ARE OF "LADDER" TYPE, WITH HORIZONTAL TIES SPACED 8 INCHES APART. 6X6 COLUMNS ERECTED ON TOP OF UNEVEN, LOOSE AND OUT OF PLUMB CEMENT-CONCRETE PADS WITHOUT BASES - FOUNDATION STATUS UNKNOWN. 2X8 LANDING JOISTS ONLY TOE-NAILED TO EDGE BEAMS. STRINGERS MISSING BOLTS AT WALLS. LANDING DECK BOARDS WRAPED AND CRACKED. RAILING SECTIONS ONLY TOE-NAILED TO 4X4 AND 6X6 COLUMNS, WITH GRADE TO 1AND BASEMENT TO GRADE RAILINGS LOOSE AND BROKEN. PLANS AND PERMIT REQUIRED TO REPAIR REAR PORCH. 7419 S INGLESIDE AVE COMPLAINT FAILED View
REPAIR EXTERIOR STAIR REAR BASEMENT TO GRADE STAIRWAY - BROKEN CONCRETE TREADS, WITH MISSING HANDRAIL. 7419 S INGLESIDE AVE COMPLAINT FAILED View
MAINTAIN WINDOW SASH 1-2ND FLOOR - WINDOW SASHES BROKEN AND ROTTING. 7419 S INGLESIDE AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION APT. 2 - NO RESPONSE - UNVERIFIED DETECTORS AND CONDITIONS. 7419 S INGLESIDE AVE COMPLAINT FAILED View
PARAPET PARAPET WALLS - SPALLING BRICKS, WITH OPEN MORTAR JOINTS. 7419 S INGLESIDE AVE COMPLAINT FAILED View
PROVIDE GUARD RAIL 42 IN HIGH REAR BASEMENT STAIRWAY - GUARDRAIL SECTIONS MISSING AT GRADE. 7419 S INGLESIDE AVE COMPLAINT FAILED View
DEFECTIVE OUTLETS APT. 1 / LIVING ROOM, DINING AND BEDROOM - OUTLETS SPARKING AND OUT OF SERVICE. 7419 S INGLESIDE AVE COMPLAINT FAILED View