The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
| Violation | Inspector Comments | Address | Category | Status | View |
|---|---|---|---|---|---|
| VENT SYSTEM TO PRVNT BACK PRES | SR-071273690 LAUNDRY TUB AND AUTOMATIC CLOTHES WASHER IN BASEMENT. (18-29-903.1)(18-29-106.1&2)PERMIT REQUIRED | 11314 S HARVARD AVE | COMPLAINT | FAILED | View |
| OBTAIN PERMIT FOR PLUMBING | (18-29-106.1&2) | 11314 S HARVARD AVE | COMPLAINT | FAILED | View |
| ENGAG LIC & BOND PLMBNG CNTRC | 1(4.332.010.100) | 11314 S HARVARD AVE | COMPLAINT | FAILED | View |
| ARRANGE PREMISE INSPECTION | 11314 S HARVARD AVE | COMPLAINT | FAILED | View | |
| ATTIC, DISCONTINUE | ATTIC FLOOR ALTERED TO FORM TWO BEDROOMS WITH NEW WALL ERECTED | 11314 S HARVARD AVE | COMPLAINT | FAILED | View |
| EGRESS | ONLY ONE MEANS OF EGRESS IS PROVIDED FOR THE ATTIC FLOOR | 11314 S HARVARD AVE | COMPLAINT | FAILED | View |
| CEILING HEIGHT - 7' | FLOOR TO CEILING HEIGHT OF ATTIC FLOOR LESS THAN 7 FEET | 11314 S HARVARD AVE | COMPLAINT | FAILED | View |
| LIGHT AND VENT | INADEQUATE NATURAL LIGHT & VENTILATION AT THE ATTIC FLOOR | 11314 S HARVARD AVE | COMPLAINT | FAILED | View |
| BASEMENT, DISCONTINUE | BASEMENT FLOOR ALTERED TO FORM TWO BEDROOMS WITH TOILET SYSTEM, NEW WALLS ERECTED | 11314 S HARVARD AVE | COMPLAINT | FAILED | View |
| STAIRWELL ENCLOSURE - BASEMENT | BASEMENT STAIRWAY INADEQUATELY ENCLOSED WITH 1 HOUR RATED DRYWALLS | 11314 S HARVARD AVE | COMPLAINT | FAILED | View |
| BELOW GRADE +2' - BASEMENT | BASEMENT HABITABLE ROOMS NOT PROTECTED AGAINST DAMPERS-SEE MILDEW FORMATIONS ON WALLS OF THE BEDROOMS | 11314 S HARVARD AVE | COMPLAINT | FAILED | View |
| CEILING HEIGHT - 7' - BASEMENT | BASEMENT FLOOR TO CEILING HEIGHT LESS THAN 7 FEET HIGH, THROUGHOUT | 11314 S HARVARD AVE | COMPLAINT | FAILED | View |
| NATURAL LIGHT NEEDED | INADEQUATE NATURAL LIGHT AT BASEMENT FLOOR. NATURAL LIGHT PENETRATION LESS THAN 8% FLOOR AREA SQUARE FOOTAGE DUE TO WALL PARTITIONS | 11314 S HARVARD AVE | COMPLAINT | FAILED | View |
| PAINT SHUT | INADEQUATE VENTILATION TO OUTER AIR AT THE BASEMENT FLOOR. VENTILATION LESS THAN 4% OF FLOOR AREA SQUARE FOOTAGE | 11314 S HARVARD AVE | COMPLAINT | FAILED | View |
| PLANS & PERMITS REQ - CONTRCTR | PLANS & PERMITS IS REQUIERD FOR ALL ALTERATIONS WORK DONE IN THE BASEMENT AND ATTIC FLOORS | 11314 S HARVARD AVE | COMPLAINT | FAILED | View |
| REPAIR INTERIOR WALLS/CEILING | HOLE IN THE 1ST FLOOR BATHROOM CEILING | 11314 S HARVARD AVE | COMPLAINT | FAILED | View |
| OBSTRUCTIONS IN EXIT WAY | REAR BASEMENT EXIT BLOCKED WITH JUNK-USED TIRES | 11314 S HARVARD AVE | COMPLAINT | FAILED | View |
| INSTALL SMOKE DETECTORS | NO SMOKE DETECTOR IN THE BASEMENT FLOOR | 11314 S HARVARD AVE | COMPLAINT | FAILED | View |
| CARB MONOX DETECT IN RESID | NO C.O. DETECTOR AT BASEMENT FURNACE ROOM | 11314 S HARVARD AVE | COMPLAINT | FAILED | View |
| DEBRIS, EXCESSIVE | REAR YARD & UNDER REAR ENCLOSED PORCH: JUNK & DEBRIS ACCUMULATION | 11314 S HARVARD AVE | COMPLAINT | FAILED | View |
| DEFECTIVE OUTLETS | NON-WORKING/DEFECTIVE WALL OUTLET AT 1ST FLOOR KITCHEN | 11314 S HARVARD AVE | COMPLAINT | FAILED | View |
| REPLCE WINDOW PANES, PLEXGLAS | REAR/WEST WINDOW PANE: BROKEN AND BOARDED | 11314 S HARVARD AVE | COMPLAINT | FAILED | View |
| STOP LEAKING WATER | LEAK UNDER KITCHEN SINK AT 1ST FLOOR & BASEMENT LAUNDRY ROOM DUE TO LOOSE PIPE | 11314 S HARVARD AVE | COMPLAINT | FAILED | View |
| SERVICE WALK, PASSAGE, AREAWAY | USED TIRES, FURNITURE, AND JUNK STORED UNDERNEATH REAR ENCLOSED PORCH SYSTEM | 11314 S HARVARD AVE | COMPLAINT | FAILED | View |