Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-22 @ 9:03 PM
PIN: 13354040040000
Property Address: 3273 W ARMITAGE AVE
City - Zip: CHICAGO - 60647
2023 Property Class: 212
2023 Township: 71 - Jefferson
2023 Neighborhood: 71180
2023 Tax District: 71169
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 57 Violations
Violation Inspector Comments Address Category Status View
TENANT ACCESS TO SERVICE TENANT REQUIRE 24 HOUR ACCESS TO FUSES AND BREAKERS 3273 W ARMITAGE AVE COMPLAINT FAILED View
DEFECTIVE OUTLETS REPLACE MISSING,WORN AND BROKEN SWITCHES AND RECEPTACLES 2ND FLOOR FRONT UNIT AND THROUGHOUT 3273 W ARMITAGE AVE COMPLAINT FAILED View
DEFECTIVE FIXTURES REPLACE ALL DEFECTIVE LIGHTING AND COVER BOXES IN COMMON AREAS 3273 W ARMITAGE AVE COMPLAINT FAILED View
SEE INSPECTOR COMMENTS INSTALL FUNCTIONAL SMOKE AND CARBON MONOXIDE DETECTORS IN COMMON AREAS AND DWELLINGS 18-27-570.10 (H) (I) 3273 W ARMITAGE AVE COMPLAINT FAILED View
FILE BLDG REGISTRATION (SR#07-01891688 AND (SR#07-01891690) BUILDING NOT REGISTERED FROM 2006-2007 3273 W ARMITAGE AVE PERIODIC FAILED View
REPAIR EXTERIOR WALL WEST ELEVATION/AT GRADE-SPALLING BRICKS AND WASHED OUT MORTAR 3273 W ARMITAGE AVE PERIODIC FAILED View
PARAPET WEST ELEVATION/PACAPET T REAR-WASHED OUT MORTAR 3273 W ARMITAGE AVE PERIODIC FAILED View
REPAIR PORCH SYSTEM REAR PORCH-FOUNDATION STATUS UNKNOWN, 6X6 AND 4X4 COLUMNS RESTING ON CONCRETE SLAB, LOOKOUT BEAMS TO NAILED INTO COLUMNS WITH GAP AT CONNECTION, 2X6 JOIST SPAN 11 FEET, STRINGERS INADEQUATELY SUPPORTED (MISSING BOLTS, RAILING ONLY 34 INCHES HIGH, RAILING AT 2ND FLOOR STAIRS WITH HORIZONTAL/PICKETS, WOOD DRY ROTTED THRU-OUT-PLANS AND PERMIT REQUIRED FOR ALL PORCH REPAIRS. 3273 W ARMITAGE AVE PERIODIC FAILED View
REPAIR EXTERIOR STAIR REAR STAIRS TO BASEMENT-HAND RAILS MISSING 3273 W ARMITAGE AVE PERIODIC FAILED View
REPAIR/REPLACE SMOKE DETECTORS INTERIOR OF BUILDING /2ND AND 3RD FLOOR CORRIDOR SMOKE DETECTORS 3273 W ARMITAGE AVE PERIODIC FAILED View
REPAIR INTERIOR STAIR SYSTEM FRONT STAIRS FROM 1ST TO 2ND-SECTION OF HANDRAIL MISSING 3273 W ARMITAGE AVE PERIODIC FAILED View
DEFECTIVE FIXTURES INTERIOR OF BUILDING/2ND FLOOR-ALL LIGHT FIXTURES BROKEN 3273 W ARMITAGE AVE PERIODIC FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING-NO RESPONSE, UNVERIFIED DETECTORS, UNABLE TO INSPECT DWELLING UNITS AND BASEMENT. 3273 W ARMITAGE AVE PERIODIC FAILED View
INSTALL DOOR VIEWING DEVICE APARTMENT ENTRANCE DOORS/BUILDING THRU-OUT-MISSING VIEWING DEVICES. 3273 W ARMITAGE AVE PERIODIC FAILED View
REPAIR INTERIOR STAIR SYSTEM FRONT STAIRS FROM 1ST TO 2ND-SECTION OF HANDRAIL MISSING 3273 W ARMITAGE AVE PERIODIC FAILED View
REMV OBSTR FROM DRAINAGE SYSTM THATS CAUSING BACK UP 3273 W ARMITAGE AVE COMPLAINT FAILED View
REPAIR CATCH BASIN 3273 W ARMITAGE AVE COMPLAINT FAILED View
PRV CAST IRON COVER FOR BASIN 3273 W ARMITAGE AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM REAR EXTERIOR PORCH / COLUMNS - SOME ERECTED ON SERVICE WALK FOUNDATION STATUS UNKNOWN. COLUMNS FROM 2ND TO 3RD FLOOR CRACKED ON 6X6 BEAM AT 1ST FLOOR. UNDERSIZED 6X6 BEAMS SPAN 10 FEET, AND SAGGING. BEAMS OPEN AT FIRECUTS AND NAILED ONLY SOME COLUMNS ARE STACKED AND OUT OF PLUMB. UNDERSIZED 2X6 DECK JOISTS SPAN 11 FEET. STRINGERS SOME ARE NAILED ONLY. RAILING SECTIONS ARE 34 INCHES HIGH. SOME RAILING SECTIONS ARE LADDER STYLE REQUIRED TO REPAIR REAR EXTERIOR PORCH. 3273 W ARMITAGE AVE PERIODIC FAILED View
PROVIDE GUARD RAIL 42 IN HIGH REAR EXTERIOR STAIRWELL BASEMENT TO GRADE SECTIONS OF GUARD RAILS MISSING. 3273 W ARMITAGE AVE PERIODIC FAILED View
PROVIDE REAR EXTERIOR PORCH / NO CURB OR BALLARDS SEPARATING PORCH FROM REAR SIDE PARKING LOT. (SEC. 7-28-06) 3273 W ARMITAGE AVE PERIODIC FAILED View
FILE BLDG REGISTRATION BUILDING - NOT REGISTERED FROM 2006- THRU 2008. 3273 W ARMITAGE AVE PERIODIC FAILED View
TENANT ACCESS TO SERVICE PROVIDE 24 HOUR ACCESS TO TENANTS FOR FUSES AND BREAKERS 3273 W ARMITAGE AVE COMPLAINT FAILED View
DEFECTIVE FIXTURES 2ND AND 3RD FLOOR CORRIDORS 3273 W ARMITAGE AVE COMPLAINT FAILED View
SEE INSPECTOR COMMENTS INSTALL FUNCTIONAL SMOKE DETECTORS IN STAIRWAYS AND ALL REQUIRED AREAS 18-27-570.10 (H) 3273 W ARMITAGE AVE COMPLAINT FAILED View
PROVIDE GUARD RAIL 42 IN HIGH REAR EXTERIOR STAIRWELL BASEMENT TO GRADE SECTIONS OF GUARD RAILS MISSING. 3273 W ARMITAGE AVE PERIODIC FAILED View
PROVIDE REAR EXTERIOR PORCH / NO CURB OR BALLARDS SEPARATING PORCH FROM REAR SIDE PARKING LOT. (SEC. 7-28-06) 3273 W ARMITAGE AVE PERIODIC FAILED View
FILE BLDG REGISTRATION REGISTER BUILDING FOR 2013. 3273 W ARMITAGE AVE PERIODIC FAILED View
NOTIFY DOB, USE OF VACANT LND 1ST FLOOR VACANT AND SECURE 3273 W ARMITAGE AVE PERIODIC FAILED View
POST OWNER/MANAGERS NAME/# BUILDING POST FULL MANAGEMENT SIGN ADDRES MISSING 3273 W ARMITAGE AVE PERIODIC FAILED View
DEBRIS, EXCESSIVE REAR JUNK 3273 W ARMITAGE AVE PERIODIC FAILED View
REPAIR PORCH SYSTEM REAR PORCH MISSING BLOCKS 3273 W ARMITAGE AVE PERIODIC FAILED View
ARRANGE PREMISE INSPECTION NO ENTRY BASEMENT,2ND 3RD 3273 W ARMITAGE AVE PERIODIC FAILED View
CHIMNEY WEST CHIMNEY; LOOSE BRICKS AND MORTAR MISSING. 3273 W ARMITAGE AVE PERIODIC FAILED View
CHIMNEY CAPPING WEST CHIMNEY CAPPING; MISSING. 3273 W ARMITAGE AVE PERIODIC FAILED View
PARAPET NORTH ELEVATION PARAPET WALL,MORTAR MISSING,LOOSE AND CHIP BRICKS,WEST PARAPET WALL,MORTAR MISSING.[DANGEROUS CONDITION] 3273 W ARMITAGE AVE PERIODIC FAILED View
REPAIR COPING NORTH COPING METAL FLASHING; BENT AND LOOSE. 3273 W ARMITAGE AVE PERIODIC FAILED View
REPAIR PORCH SYSTEM SOUTH PORCH; LOOKOUTS TOE NAIL TO SUPPORTS AND PULLING AWAY,NO FOOTINGS,2X6 DECK JOIST UNDER SIZE FOR SPAN,HORIZONTAL GUARD RAILS AND UNDER SIZE,LEDGER BOARD PULLING AWAY FROM THE WALL,UPRIGHTS BUTT JOINTS,TREADS AND DECKING WOOD SPLIT,STRINGERS NOT SITTING FLUSH ON DECKING SITTING ON BOX STEP.[SUBMIT PLANS AND PERMITS TO REPLACE]. 3273 W ARMITAGE AVE PERIODIC FAILED View
NOTIFY DOB, USE OF VACANT LND 2ND AND 3RD FLR.APARTMENTS VACANT AND OPEN. 3273 W ARMITAGE AVE PERIODIC FAILED View
INSTALL SMOKE DETECTORS BUILDING INTERIOR NO SMOKE DETECTOR. 3273 W ARMITAGE AVE PERIODIC FAILED View
CARB MONOX DETECT IN RESID BUILDING INTERIOR NO CARBON MONOXIDE. 3273 W ARMITAGE AVE PERIODIC FAILED View
CARPETING BUILDING INTERIOR CARPET; UNSANITARY CONDITION. 3273 W ARMITAGE AVE PERIODIC FAILED View
REPAIR FLOOR 2ND AND 3RD FLR.CORRIDOR UNDER CARPET; WEAK FLOORING. 3273 W ARMITAGE AVE PERIODIC FAILED View
EXPOSED WIRING 2ND AND 3RD FLR.APARTMENTS; EXPOSED WIRING. 3273 W ARMITAGE AVE PERIODIC FAILED View
REPAIR INTERIOR WALLS/CEILING BUILDING INTERIOR 2ND AND 3RD FLR.DRYWALL; BROKEN. 3273 W ARMITAGE AVE PERIODIC FAILED View
PERMIT REQUIRED NO PERMIT TO REDUCE WEST WINDOW SIZE. 3273 W ARMITAGE AVE PERIODIC FAILED View
MAINTAIN WINDOW WEST ELEVATION WINDOW FRAMES; BROKEN. 3273 W ARMITAGE AVE PERIODIC FAILED View
ARRANGE PERMIT INSP. 3273 W ARMITAGE AVE PERMIT FAILED View
ARRANGE PERMIT INSP. 3273 W ARMITAGE AVE PERMIT FAILED View
TENANT ACCESS TO SERVICE TENANTS REQUIRED 24 HOURS ACCESS TO ALL BREAKERS AND FUSES POWER OFF 2ND TIME IN A MONTH DANGEROUS AND HAZARDOUS 3273 W ARMITAGE AVE COMPLAINT FAILED View
EXPOSED WIRING FIXTURES ALL STAIRWAYS AND HALLWAYS 3273 W ARMITAGE AVE COMPLAINT FAILED View
PROPER SIZE OCP TO PREVENT BLOWING FUSES BREAKERS AT 2A 3273 W ARMITAGE AVE COMPLAINT FAILED View
EXPOSED WIRING ALL APARTMENTS PROVIDE PROPER WIRING METHODS PERMITS REQUIRED 3273 W ARMITAGE AVE COMPLAINT FAILED View
SEE INSPECTOR COMMENTS PROVIDE ACCESS TO ALL AREAS FOR COMPLETE INSPECTION 13-12-400 3273 W ARMITAGE AVE COMPLAINT FAILED View
CLEAN CATCH BASIN 3273 W ARMITAGE AVE COMPLAINT FAILED View
LICENSED BONDED PLMBG CONTRCTR 3273 W ARMITAGE AVE COMPLAINT FAILED View
ARRANGE PERMIT INSP. 3273 W ARMITAGE AVE PERMIT FAILED View