The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
TENANT ACCESS TO SERVICE | TENANT REQUIRE 24 HOUR ACCESS TO FUSES AND BREAKERS | 3273 W ARMITAGE AVE | COMPLAINT | FAILED | View |
DEFECTIVE OUTLETS | REPLACE MISSING,WORN AND BROKEN SWITCHES AND RECEPTACLES 2ND FLOOR FRONT UNIT AND THROUGHOUT | 3273 W ARMITAGE AVE | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | REPLACE ALL DEFECTIVE LIGHTING AND COVER BOXES IN COMMON AREAS | 3273 W ARMITAGE AVE | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | INSTALL FUNCTIONAL SMOKE AND CARBON MONOXIDE DETECTORS IN COMMON AREAS AND DWELLINGS 18-27-570.10 (H) (I) | 3273 W ARMITAGE AVE | COMPLAINT | FAILED | View |
FILE BLDG REGISTRATION | (SR#07-01891688 AND (SR#07-01891690) BUILDING NOT REGISTERED FROM 2006-2007 | 3273 W ARMITAGE AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | WEST ELEVATION/AT GRADE-SPALLING BRICKS AND WASHED OUT MORTAR | 3273 W ARMITAGE AVE | PERIODIC | FAILED | View |
PARAPET | WEST ELEVATION/PACAPET T REAR-WASHED OUT MORTAR | 3273 W ARMITAGE AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH-FOUNDATION STATUS UNKNOWN, 6X6 AND 4X4 COLUMNS RESTING ON CONCRETE SLAB, LOOKOUT BEAMS TO NAILED INTO COLUMNS WITH GAP AT CONNECTION, 2X6 JOIST SPAN 11 FEET, STRINGERS INADEQUATELY SUPPORTED (MISSING BOLTS, RAILING ONLY 34 INCHES HIGH, RAILING AT 2ND FLOOR STAIRS WITH HORIZONTAL/PICKETS, WOOD DRY ROTTED THRU-OUT-PLANS AND PERMIT REQUIRED FOR ALL PORCH REPAIRS. | 3273 W ARMITAGE AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | REAR STAIRS TO BASEMENT-HAND RAILS MISSING | 3273 W ARMITAGE AVE | PERIODIC | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | INTERIOR OF BUILDING /2ND AND 3RD FLOOR CORRIDOR SMOKE DETECTORS | 3273 W ARMITAGE AVE | PERIODIC | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | FRONT STAIRS FROM 1ST TO 2ND-SECTION OF HANDRAIL MISSING | 3273 W ARMITAGE AVE | PERIODIC | FAILED | View |
DEFECTIVE FIXTURES | INTERIOR OF BUILDING/2ND FLOOR-ALL LIGHT FIXTURES BROKEN | 3273 W ARMITAGE AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING-NO RESPONSE, UNVERIFIED DETECTORS, UNABLE TO INSPECT DWELLING UNITS AND BASEMENT. | 3273 W ARMITAGE AVE | PERIODIC | FAILED | View |
INSTALL DOOR VIEWING DEVICE | APARTMENT ENTRANCE DOORS/BUILDING THRU-OUT-MISSING VIEWING DEVICES. | 3273 W ARMITAGE AVE | PERIODIC | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | FRONT STAIRS FROM 1ST TO 2ND-SECTION OF HANDRAIL MISSING | 3273 W ARMITAGE AVE | PERIODIC | FAILED | View |
REMV OBSTR FROM DRAINAGE SYSTM | THATS CAUSING BACK UP | 3273 W ARMITAGE AVE | COMPLAINT | FAILED | View |
REPAIR CATCH BASIN | 3273 W ARMITAGE AVE | COMPLAINT | FAILED | View | |
PRV CAST IRON COVER FOR BASIN | 3273 W ARMITAGE AVE | COMPLAINT | FAILED | View | |
REPAIR PORCH SYSTEM | REAR EXTERIOR PORCH / COLUMNS - SOME ERECTED ON SERVICE WALK FOUNDATION STATUS UNKNOWN. COLUMNS FROM 2ND TO 3RD FLOOR CRACKED ON 6X6 BEAM AT 1ST FLOOR. UNDERSIZED 6X6 BEAMS SPAN 10 FEET, AND SAGGING. BEAMS OPEN AT FIRECUTS AND NAILED ONLY SOME COLUMNS ARE STACKED AND OUT OF PLUMB. UNDERSIZED 2X6 DECK JOISTS SPAN 11 FEET. STRINGERS SOME ARE NAILED ONLY. RAILING SECTIONS ARE 34 INCHES HIGH. SOME RAILING SECTIONS ARE LADDER STYLE REQUIRED TO REPAIR REAR EXTERIOR PORCH. | 3273 W ARMITAGE AVE | PERIODIC | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | REAR EXTERIOR STAIRWELL BASEMENT TO GRADE SECTIONS OF GUARD RAILS MISSING. | 3273 W ARMITAGE AVE | PERIODIC | FAILED | View |
PROVIDE | REAR EXTERIOR PORCH / NO CURB OR BALLARDS SEPARATING PORCH FROM REAR SIDE PARKING LOT. (SEC. 7-28-06) | 3273 W ARMITAGE AVE | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | BUILDING - NOT REGISTERED FROM 2006- THRU 2008. | 3273 W ARMITAGE AVE | PERIODIC | FAILED | View |
TENANT ACCESS TO SERVICE | PROVIDE 24 HOUR ACCESS TO TENANTS FOR FUSES AND BREAKERS | 3273 W ARMITAGE AVE | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | 2ND AND 3RD FLOOR CORRIDORS | 3273 W ARMITAGE AVE | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | INSTALL FUNCTIONAL SMOKE DETECTORS IN STAIRWAYS AND ALL REQUIRED AREAS 18-27-570.10 (H) | 3273 W ARMITAGE AVE | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | REAR EXTERIOR STAIRWELL BASEMENT TO GRADE SECTIONS OF GUARD RAILS MISSING. | 3273 W ARMITAGE AVE | PERIODIC | FAILED | View |
PROVIDE | REAR EXTERIOR PORCH / NO CURB OR BALLARDS SEPARATING PORCH FROM REAR SIDE PARKING LOT. (SEC. 7-28-06) | 3273 W ARMITAGE AVE | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | REGISTER BUILDING FOR 2013. | 3273 W ARMITAGE AVE | PERIODIC | FAILED | View |
NOTIFY DOB, USE OF VACANT LND | 1ST FLOOR VACANT AND SECURE | 3273 W ARMITAGE AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING POST FULL MANAGEMENT SIGN ADDRES MISSING | 3273 W ARMITAGE AVE | PERIODIC | FAILED | View |
DEBRIS, EXCESSIVE | REAR JUNK | 3273 W ARMITAGE AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH MISSING BLOCKS | 3273 W ARMITAGE AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY BASEMENT,2ND 3RD | 3273 W ARMITAGE AVE | PERIODIC | FAILED | View |
CHIMNEY | WEST CHIMNEY; LOOSE BRICKS AND MORTAR MISSING. | 3273 W ARMITAGE AVE | PERIODIC | FAILED | View |
CHIMNEY CAPPING | WEST CHIMNEY CAPPING; MISSING. | 3273 W ARMITAGE AVE | PERIODIC | FAILED | View |
PARAPET | NORTH ELEVATION PARAPET WALL,MORTAR MISSING,LOOSE AND CHIP BRICKS,WEST PARAPET WALL,MORTAR MISSING.[DANGEROUS CONDITION] | 3273 W ARMITAGE AVE | PERIODIC | FAILED | View |
REPAIR COPING | NORTH COPING METAL FLASHING; BENT AND LOOSE. | 3273 W ARMITAGE AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | SOUTH PORCH; LOOKOUTS TOE NAIL TO SUPPORTS AND PULLING AWAY,NO FOOTINGS,2X6 DECK JOIST UNDER SIZE FOR SPAN,HORIZONTAL GUARD RAILS AND UNDER SIZE,LEDGER BOARD PULLING AWAY FROM THE WALL,UPRIGHTS BUTT JOINTS,TREADS AND DECKING WOOD SPLIT,STRINGERS NOT SITTING FLUSH ON DECKING SITTING ON BOX STEP.[SUBMIT PLANS AND PERMITS TO REPLACE]. | 3273 W ARMITAGE AVE | PERIODIC | FAILED | View |
NOTIFY DOB, USE OF VACANT LND | 2ND AND 3RD FLR.APARTMENTS VACANT AND OPEN. | 3273 W ARMITAGE AVE | PERIODIC | FAILED | View |
INSTALL SMOKE DETECTORS | BUILDING INTERIOR NO SMOKE DETECTOR. | 3273 W ARMITAGE AVE | PERIODIC | FAILED | View |
CARB MONOX DETECT IN RESID | BUILDING INTERIOR NO CARBON MONOXIDE. | 3273 W ARMITAGE AVE | PERIODIC | FAILED | View |
CARPETING | BUILDING INTERIOR CARPET; UNSANITARY CONDITION. | 3273 W ARMITAGE AVE | PERIODIC | FAILED | View |
REPAIR FLOOR | 2ND AND 3RD FLR.CORRIDOR UNDER CARPET; WEAK FLOORING. | 3273 W ARMITAGE AVE | PERIODIC | FAILED | View |
EXPOSED WIRING | 2ND AND 3RD FLR.APARTMENTS; EXPOSED WIRING. | 3273 W ARMITAGE AVE | PERIODIC | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | BUILDING INTERIOR 2ND AND 3RD FLR.DRYWALL; BROKEN. | 3273 W ARMITAGE AVE | PERIODIC | FAILED | View |
PERMIT REQUIRED | NO PERMIT TO REDUCE WEST WINDOW SIZE. | 3273 W ARMITAGE AVE | PERIODIC | FAILED | View |
MAINTAIN WINDOW | WEST ELEVATION WINDOW FRAMES; BROKEN. | 3273 W ARMITAGE AVE | PERIODIC | FAILED | View |
ARRANGE PERMIT INSP. | 3273 W ARMITAGE AVE | PERMIT | FAILED | View | |
ARRANGE PERMIT INSP. | 3273 W ARMITAGE AVE | PERMIT | FAILED | View | |
TENANT ACCESS TO SERVICE | TENANTS REQUIRED 24 HOURS ACCESS TO ALL BREAKERS AND FUSES POWER OFF 2ND TIME IN A MONTH DANGEROUS AND HAZARDOUS | 3273 W ARMITAGE AVE | COMPLAINT | FAILED | View |
EXPOSED WIRING FIXTURES | ALL STAIRWAYS AND HALLWAYS | 3273 W ARMITAGE AVE | COMPLAINT | FAILED | View |
PROPER SIZE OCP | TO PREVENT BLOWING FUSES BREAKERS AT 2A | 3273 W ARMITAGE AVE | COMPLAINT | FAILED | View |
EXPOSED WIRING | ALL APARTMENTS PROVIDE PROPER WIRING METHODS PERMITS REQUIRED | 3273 W ARMITAGE AVE | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | PROVIDE ACCESS TO ALL AREAS FOR COMPLETE INSPECTION 13-12-400 | 3273 W ARMITAGE AVE | COMPLAINT | FAILED | View |
CLEAN CATCH BASIN | 3273 W ARMITAGE AVE | COMPLAINT | FAILED | View | |
LICENSED BONDED PLMBG CONTRCTR | 3273 W ARMITAGE AVE | COMPLAINT | FAILED | View | |
ARRANGE PERMIT INSP. | 3273 W ARMITAGE AVE | PERMIT | FAILED | View |