Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR HANDRAILS | REPLACE HANDRAILS (42" MIN.) | 6347 N RIDGE AVE | COMPLAINT | FAILED | View |
ALL HANDRAIL SUPPORTS | REANCHOR HANDRAILS | 6347 N RIDGE AVE | COMPLAINT | FAILED | View |
SEND EX. METAL LETTER | EXPOSED METAL LETTER | 6347 N RIDGE AVE | COMPLAINT | FAILED | View |
REPAIR STRINGER CHANNELS | REPAIR CHANNELS (WALKWAY) | 6347 N RIDGE AVE | COMPLAINT | FAILED | View |
REPAIR CHECKER PLATE | REPLACE CHECKER PLATES | 6347 N RIDGE AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | SOUTH ELEVATION /EXTERIOR WALL - SHIFTED BRICK SECTIONS WITH WASHED OUT MORTAR; DEFLECTIONS WITH OPEN MORTAR JOINTS UNDER BALCONY CONNECTIONS. WEST ELEVATION /EXTERIOR WALL - LARGE OPEN MORTAR JOINTS AT BASE OF WALL. NORTH ELEVATION /EXTERIOR WALL - SPALLED BRICK SECTIONS WITH WASHED OUT MORTAR. | 6347 N RIDGE AVE | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | NORTH ELEVATION /SERVICE WALK - LARGE FRACTURES IN CONCRETE WALKWAY NEAR COLUMN LOCATION. | 6347 N RIDGE AVE | COMPLAINT | FAILED | View |
PROVIDE | PROVIDE PER CODE SECTION 14A-6-603.3 THROUGH 14A-6-603.3.4. RAISED EXTERIOR WALKWAYS PERMANENTLY INSTALLED ON THE EXTERIOR OF A BUILDING. PROVIDE CRITICAL EXAMINATION REPORT ON EXPOSED METAL STRUCTURES BY A REGISTERED DESIGN PROFESSIONAL WITHIN 2 YEARS AFTER ITS INSTALLATION AND AT LEAST ONCE EVERY 5 YEARS AFTER THE INITIAL INSPECTION. THE REGISTERED DESIGN PROFESSIONAL MUST PREPARE THE SIGNED AND SEALED WRITTEN REPORT ON THE EXTERNAL STRUCTURAL CONDITION AND INTEGRITY OF THE EXPOSED METAL STRUCTURE AND PROVIDE TO OWNER. PROJECTIONS SUCH AS CANOPIES, MARQUEES, AWNINGS, MUST BE MAINTAINED IN GOOD REPAIR AND BE PROPERLY ANCHORED. METAL SURFACES SUBJECT TO RUST OR CORROSION MUST BE COATED TO INHIBIT SUCH RUST AND CORROSION, AND SURFACES WITH RUST OR CORROSION MUST BE STABILIZED AND COATED TO INHIBIT FUTURE RUST AND CORROSION. SEND REPORTS TO: DEPARTMENT OF BUILDINGS CODE COMPLIANCE GROUP, 2045 W. WASHINGTON BLVD. CHICAGO, IL 60612. (14A-6-603.3 THROUGH 14A-6-603.3.4, 14X-3-303.2, 14X-3-303.9, 14X-5-505.12, 14R-3-307, 14R-3-307.6 AND 14A-4-404.8) | 6347 N RIDGE AVE | COMPLAINT | FAILED | View |
REPAIR BALCONY | NORTH AND SOUTH ELEVATIONS /RAISED EXTERIOR WALKWAYS - SEVERELY CORRODED WITH BUILD UP THROUGHOUT; LANDINGS - RUSTED AND SCALING; METAL RAILINGS LOOSE AND PULLING; UNDERSIDE OF BALCONIES - SPALLED CONCRETE SECTIONS. | 6347 N RIDGE AVE | COMPLAINT | FAILED | View |