The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER INFO ON ABDN BLDG | 11906 S MICHIGAN AVE | COMPLAINT | CLOSED | View | |
VACANT BUILDING - REGISTER | 11906 S MICHIGAN AVE | COMPLAINT | CLOSED | View | |
SUBMIT FOR APPROVAL PLANS | 11906 S MICHIGAN AVE | COMPLAINT | CLOSED | View | |
MAINTAN BLDG IN SAFE CONDITION | 11906 S MICHIGAN AVE | COMPLAINT | CLOSED | View | |
REPAIR/WRECK DANGER RESID PREM | 11906 S MICHIGAN AVE | COMPLAINT | CLOSED | View | |
WATCHMAN | 11906 S MICHIGAN AVE | COMPLAINT | CLOSED | View | |
REPAIR PORCH SYSTEM | REAR 2 STORY OPEN WOOD PORCH - COLUMNS ERECTED ON CONCRETE SLABS AND CONCRETE BLOCKS , ONE 4 X 4 COLUMN AT STAIRS - LOOSE AND FLOATING ABOVE CONCRETE - FOUNDATION STATUS UNKNOWN. TWISTED COLUMNS , STACKED COLUMNS. 6 X 6 BEAMS WITH OPEN FIRE CUTS , ONE AT CENTER PULLING AWAY FROM BEAM AND ONLY NAILED. LEDGER BEAM ONLY NAILED TO BUILDING AND SUPPORTED BY ONE 6 X 6 BEAM IN MIDDLE. 2 X 8 BEAMS ONLY NAILED TO COLUMNS. UNDERSIZED 2 X 8 DECK JOISTS OVERSPANNED AT 15' [ WEST ELEVATION ] . 2 X 8 DECK JOISTS ONLY NAILED TO LEDGER BEAM AND RIM JOISTS , SPACED 21'' TO 34'' ON CENTERS [ SOUTH ELEVATION ]. UNDERSIZED STRINGERS OVERSPANNED AT 16' AND ONLY NAILED TO COLUMNS AND JOISTS. GUARDRAILS AND HANDRAILS - LOOSE WITH LOOSE AND MISSING PICKETS. STAIR TREADS AND DECKING - SPLIT , WORN , AND ROTTED. DECK SWAYS 2'' TO 4'' - UNSTABLE AND WEAK - PORCH IS MIISING BRACING. PLANS AND PERMIT REQUIRED FOR PORCH REPAIRS. | 11906 S MICHIGAN AVE | COMPLAINT | FAILED | View |
PARAPET | NORTH , WEST , AND SOUTH PARAPETS - WASHED OUT MORTAR , SHIFTING BRICKS , AND SPALLING BRICKS. | 11906 S MICHIGAN AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | NORTH WALL - WASHED OUT MORTAR AND SPALLING BRICKS. EAST ABOVE 2ND FLOOR WINDOWS - LIMESTONE WITH OPEN MORTAR JOINTS. | 11906 S MICHIGAN AVE | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | SOUTH AND WEST SERVICE WALKS AT PORCH AREA - UNEVEN , COLLAPSING SURFACES WITH BROKEN AND FRACTURED CONCRETE. | 11906 S MICHIGAN AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | SOUTH AT 1ST AND EAST AT 2ND - WINDOWS - BROKEN / CRACKED PANES. | 11906 S MICHIGAN AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | SOUTH AT 1ST AND EAST AT 2ND - WINDOW FRAMES - ROTTED WITH PEELING PAINT. | 11906 S MICHIGAN AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW SASH | SOUTH AT 1ST AND EAST AT 2ND - WINDOW SASHES ROTTED WITH PEELING PAINT. | 11906 S MICHIGAN AVE | COMPLAINT | FAILED | View |
REPAIR WINDOW SILLS | EAST AT 2ND - STONE WINDOW SILLS - OPEN MORTAR JOINTS. | 11906 S MICHIGAN AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING OWNER' S ID SIGN - MISSING. | 11906 S MICHIGAN AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | 1ST FLOOR - NORTH UNIT - CARBON MONOXIDE DETECTOR - MISSING. | 11906 S MICHIGAN AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | BUILDING INTERIOR - NO RESPONSE - MOST APARTMENTS AND BASEMENT - UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO INSPECT BASEMENT STAIRWAY OR VERIFY COMPLAINT OF BAD ODOR AND LEAKS - [PER OWNER / MANAGER- NO INTERIOR STAIRWAYS ]. | 11906 S MICHIGAN AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO RESPONSE TO INTERIOR TO VERIFY OCCUPANCY, DETECTORS, REAR, AND COMPLAINT OF UNIT 2 RODENTS, RATS, AND NO HOT WATER. | 11906 S MICHIGAN AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING MISSING OWNERSHIP/ MANAGEMENT INFORMATION NAME, PHONE, AND ADDRESS. | 11906 S MICHIGAN AVE | COMPLAINT | FAILED | View |
REPAIR SCREENS | FRONT 2ND FLOOR MISSING WINDOW SCREENS. | 11906 S MICHIGAN AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | NORTH ELEVATION 2ND FLR.WINDOW PANE; BROKEN. | 11906 S MICHIGAN AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR FRAME | SOUTH ELEVATION EXTERIOR DOOR FRAME; BROKEN. | 11906 S MICHIGAN AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | POST OWNERSHIP ON BUILDING. | 11906 S MICHIGAN AVE | COMPLAINT | FAILED | View |
PARAPET | SOUTH EXTERIOR WALL; BUCKLING OUT [SUBMIT PERMITS TO RESET BRICKS]. | 11906 S MICHIGAN AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | 1ST FLR.KITCHEN CEILING; WATER DAMAGE. | 11906 S MICHIGAN AVE | COMPLAINT | FAILED | View |
REPAIR FLOOR | 1ST FLR.AREA,FLOOR TILE BROKEN,WOOD FLOORING BROKEN,BATHROOM FLOOR CAVING IN. | 11906 S MICHIGAN AVE | COMPLAINT | FAILED | View |
RESET LOOSE FIXTURE | 1ST FLR.BATHROOM TOILET AND SINK; LOOSE. | 11906 S MICHIGAN AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO BASEMENT AND 2ND FLR.APARTMENTS. | 11906 S MICHIGAN AVE | COMPLAINT | FAILED | View |
1HR FLR OVER BSMT, 1 OR 2 DU | BASEMENT CEILING - EXPOSED WOOD LATH. | 11906 S MICHIGAN AVE | COMPLAINT | FAILED | View |
PARAPET | SOUTH PARAPET WALL AT 11908 S./ - LEANNING TOWARD ROOF.MASONRY PERMIT REQUIRED FOR REPAIRS. | 11906 S MICHIGAN AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | SOUTH ELEVATION EXTERIOR DOOR; BROKEN. | 11906 S MICHIGAN AVE | COMPLAINT | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | WINDOW SCREENS; MISSING. | 11906 S MICHIGAN AVE | COMPLAINT | FAILED | View |