Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | BUILDING - NO OWNER'S I.D. SIGN POSTED. | 7941 S GREEN ST | COMPLAINT | PASSED | View |
SCREEN OUTER DOORS, WINDOWS | ALL ELEVATIONS/ VARIOUS WINDOWS - MISSING SCREENS. | 7941 S GREEN ST | COMPLAINT | PASSED | View |
REPAIR EXTERIOR WALL | NORTH ELEVATION/ EXTERIOR WALL - FRACTURED MASONRY NEAR WEST END.NORTH AND SOUTH ELEVATIONS/ EXTERIOR WALLS - SEVERE WASHED OUT MORTAR. | 7941 S GREEN ST | COMPLAINT | PASSED | View |
PARAPET | FRONT ELEVATION/ PARAPET WALL - WASHED OUT MORTAR.SOUTH ELEVATION/ PARAPET WALL - SPALLING AND LOOSE BRICKS WITH WASHED OUT MORTAR; LEANING INWARD. (FALLING MASONRY OVER PUBLIC SERVICE WALK)DANGEROUS AND HAZARDOUS CONDITIONS.PERMIT REQUIRED FOR MASONRY REPAIRS TO SOUTH PARAPET WALL. | 7941 S GREEN ST | COMPLAINT | FAILED | View |
CHIMNEY | SOUTH ELEVATION/ CHIMNEY - SPALLING AND LOOSE BRICKS WITH WASHED OUT MORTAR. | 7941 S GREEN ST | COMPLAINT | PASSED | View |
CHIMNEY CAPPING | SOUTH ELEVATION/ CHIMNEY - MISSING CAPPING. | 7941 S GREEN ST | COMPLAINT | PASSED | View |
OBSTRUCTIONS IN EXIT WAY | SOUTH ELEVATION/ BASEMENT ENTRY WAY - GATED AND PAD LOCKED. | 7941 S GREEN ST | COMPLAINT | PASSED | View |
PROVIDE GUARD RAIL 42 IN HIGH | SOUTH ELEVATION/ GRADE TO BASEMENT STAIRWAY - GUARD RAILS ONLY 31 INCHES HIGH.REAR ELEVATION/ GRADE TO BASEMENT STAIRWAY - MISSING GUARD RAILS. | 7941 S GREEN ST | COMPLAINT | PASSED | View |
REPAIR EXTERIOR STAIR | REAR GRADE TO BASEMENT STAIRWAY - MISSING HAND RAILS. | 7941 S GREEN ST | COMPLAINT | PASSED | View |
REPLACE D&H PORCH | REAR PARTIALLY ENCLOSED 2-STORY WOOD PORCH/ CORNER COLUMNS - DOUBLE NOTCHED FOR RIM JOISTS AND HEADER JOISTS AND ROTTED. CENTER COLUMN - TWISTED OUT OF PLUMB. 1ST AND 2ND FLOOR DECKS - EXCESSIVE SLOPES. BEAMS - ONLY NAILED TO COLUMNS. 2ND FLOOR CENTER BEAM - PULLING AWAY FROM COLUMN WITH ONLY 1/4 INCH OF WOOD REMAINING. UNDERSIZED 2X8 DECK JOISTS SPAN 13 FEET. UNDERSIZED 2X6 ROOF JOISTS SPAN 10 FEET.HEADER JOISTS - ONLY NAILED TO COLUMNS AND ROTTED. STRINGERS - UPPER ENDS INADEQUATELY SUPPORTED WITH NAILS ONLY AND ALL STRINGERS ARE ROTTED. RAILINGS - ROTTED; ONLY 30 TO 34 INCHES HIGH AND ONLY NAILED TO COLUMNS AND POSTS. STAIR RAILINGS - ROTTED, ONLY 25 INCHES HIGH AND ONLY NAILED TO COLUMNS AND POSTS.DECK BOARDS - ROTTED THROUGHOUT. UNABLE TO INSPECT THE ENCLOSED PORTION.DANGEROUS AND HAZARDOUS CONDITIONS.PLANS AND PERMIT REQUIRED TO REPLACE REAR PORCH. | 7941 S GREEN ST | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | REAR PARTIALLY ENCLOSED 2-STORY WOOD PORCH/ CORNER COLUMNS - DOUBLE NOTCHED FOR RIM JOISTS AND HEADER JOISTS AND ROTTED. CENTER COLUMN - TWISTED OUT OF PLUMB. 1ST AND 2ND FLOOR DECKS - EXCESSIVE SLOPES. BEAMS - ONLY NAILED TO COLUMNS. 2ND FLOOR CENTER BEAM - PULLING AWAY FROM COLUMN WITH ONLY 1/4 INCH OF WOOD REMAINING. UNDERSIZED 2X8 DECK JOISTS SPAN 13 FEET. UNDERSIZED 2X6 ROOF JOISTS SPAN 10 FEET.HEADER JOISTS - ONLY NAILED TO COLUMNS AND ROTTED. STRINGERS - UPPER ENDS INADEQUATELY SUPPORTED WITH NAILS ONLY AND ALL STRINGERS ARE ROTTED. RAILINGS - ROTTED; ONLY 30 TO 34 INCHES HIGH AND ONLY NAILED TO COLUMNS AND POSTS. STAIR RAILINGS - ROTTED, ONLY 25 INCHES HIGH AND ONLY NAILED TO COLUMNS AND POSTS.DECK BOARDS - ROTTED THROUGHOUT. UNABLE TO INSPECT THE ENCLOSED PORTION.DANGEROUS AND HAZARDOUS CONDITIONS.PLANS AND PERMIT REQUIRED TO REPLACE REAR PORCH. | 7941 S GREEN ST | COMPLAINT | PASSED | View |
PARAPET | FRONT ELEVATION/ PARAPET WALL - WASHED OUT MORTAR.SOUTH ELEVATION/ PARAPET WALL - SPALLING AND LOOSE BRICKS WITH WASHED OUT MORTAR; LEANING INWARD. (FALLING MASONRY OVER PUBLIC SERVICE WALK)DANGEROUS AND HAZARDOUS CONDITIONS.PERMIT REQUIRED FOR MASONRY REPAIRS TO SOUTH PARAPET WALL. | 7941 S GREEN ST | COMPLAINT | PASSED | View |
STOP/REMOVE NUISANCE | NORTH AND SOUTH ELEVATIONS/ BASEMENT WINDOWS - METAL BARS OVER WINDOWS. | 7941 S GREEN ST | COMPLAINT | PASSED | View |
MAINTAIN WINDOW SASH | NORTH ELEVATION/ WINDOW SASHES - ROTTED WITH PEELING PAINT. | 7941 S GREEN ST | COMPLAINT | PASSED | View |
MAINTAIN WINDOW | NORTH ELEVATION/ WINDOW FRAMES - ROTTED WITH PEELING PAINT. | 7941 S GREEN ST | COMPLAINT | PASSED | View |