POST OWNER/MANAGERS NAME/# | OWNER / MANAGEMENT SIGN, MISSING. | 1967 N DAYTON ST | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | NO CURRENT BUILDING REGISTRATION ON FILE. | 1967 N DAYTON ST | PERIODIC | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | NO ENTRY TO ALL DWELLING UNITS. ARRANGE FOR INTERIOR INSPECTION TO VERIFY OCCUPANCY AND DETECTORS. | 1967 N DAYTON ST | PERIODIC | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | 1967 N DAYTON ST, BASEMENT TO 4TH FLOOR, INTERIOR STAIRWAY, TOP OF STAIRWAY, SMOKE DETECTOR, NOT WORKING. | 1967 N DAYTON ST | PERIODIC | FAILED | View |
INSTALL SMOKE DETECTORS | MULTIPLE LOCATIONS, SMOKE DETECTORS, MISSING: 1) BASEMENT, LAUNDRY ROOM, SMOKE DETECTOR, MISSING; 2) 825 W ARMITAGE AVE, GROUND FLOOR, COMMERCIAL SPACE, BACK DOOR AREA, FURNACE INSTALLED, SMOKE DETECTOR, MISSING. | 1967 N DAYTON ST | PERIODIC | FAILED | View |
CARB MONOX DETECT IN RESID | MULTIPLE LOCATIONS, CARBON MONOXIDE DETECTORS, MISSING: 1) BASEMENT, LAUNDRY ROOM, CARBON MONOXIDE DETECTOR, MISSING; 2) 825 W ARMITAGE AVE, GROUND FLOOR, COMMERCIAL SPACE, BACK EXIT AREA, FURNACE INSTALLED, CARBON MONOXIDE DETECTOR, MISSING. | 1967 N DAYTON ST | PERIODIC | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | 1) 1967 N DAYTON ST, BASEMENT TO 4TH FLOOR, INTERIOR STAIWAY, 4TH FLOOR LANDING, ACCUMULATION OF BOXES, ETC., OBSTRUCTING PATH OF EGRESS; 2) 825 W ARMITAGE AVE, GROUND FLOOR, COMMERCIAL SPACE, BACK EXIT AREA, FURNACE INSTALLED, OBSTRUCTING PATH OF EGRESS; 3) SOUTH ELEVATION, FOUR STORY, WOOD PORCH STRUCTURE, 4TH FLOOR LANDING AND STAIRS 3RD TO 4TH FLOOR, ACCUMULATION OF FLOWER POTS, HOSES, ETC., OBSTRUCTING PATH OF EGRESS. | 1967 N DAYTON ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | 1) DANGEROUS AND HAZARDOUS. WEST ELEVATION, MIDDLE OF THE BUILDING, ABOVE ENTRANCE TO 1967 N DAYTON ST, LARGE LIMESTONE MASONRY, SPLIT, SAGIING, SHIFTING, OVER PUBLIC WAY. OBTAIN PLANS AND PERMIT FOR REPAIRS; 2) WEST ELEVATION, MIDDLE OF THE BUILDING, ABOVE ENTRANCE TO 1967 N DAYTON ST, 2ND TO 3RD FLOORS, WASHED OUT MORTAR, SPALLING MASONRY, OVER PUBLIC WAY. OBTAIN PERMIT FOR REPAIRS; 3) DANGEROUS AND HAZARDOUS. WEST ELEVATION, ABOVE 2ND STORY WINDOWS, 2ND AND 3RD WINDOWS FROM NORTH-WEST CORNER'S BAY WINDOWS, LARGE LIMESTONE MASONRY, SEVERELY CRACKED, SPLITING, SHIFTING, SPALLING, OVER PUBLIC WAY. OBTAIN PLANS AND PERMIT FOR REPAIRS; 4) DANGEROUS AND HAZARDOUS. WEST ELEVATION, NORTH-WEST CORNER, ABOVE STOREFRONT, MASONRY, SEVERE BULGING, SHIFTING, STEP FRACTURES, LARGE LIMESTONES, SPLIT, BULGING, OVER PUBLIC WAY. OBTAIN PLANS AND PERMIT FOR REPAIRS; 5) NORTH-EAST CORNER, ABOVE STOREFRONT, AT 1ST WINDOW FROM NORTH-EAST CORNER, MASONRY, CRACKING, SPALLING. OBTAIN PERMIT FOR REPAIRS. | 1967 N DAYTON ST | PERIODIC | FAILED | View |
NO CLOSET/STORAGE UNDER STAIR | SOUTH ELEVATION, FOUR STORY, WOOD PORCH SYSTEM, GROUND LEVEL, UNDER THE STAIR STORAGE. NO ENTRY, OBSERVED FROM PUBLIC WAY. | 1967 N DAYTON ST | PERIODIC | FAILED | View |
REPLACE D&H PORCH | DANGEROUS AND HAZARDOUS. SOUTH ELEVATION, FOUR STORY WOOD PORCH SYSTEM: 1) NO VISIBLE FOOTING UNDER THE COLUMNS; 2) GROUND TO 4TH FLOOR, ALL HANDRAILS, LADDER EFFECT, PICKETS MISSING; 3) GROUND TO 4TH FLOOR, MULTPLE LOCATIONS, STAIR STRINGERS, CUT IN THE SPAN, INADEQUATELY SUPPORTED AT HEADER JOISTS AND COLUMNS; 4) GROUND TO 4TH FLOOR, MULTIPLE LOCATIONS, SUPPORT COLUMNS, HAVE INADEQUATE HALF-LAP JOINTS, PULLING APART, WITH ONLY TWO BOLTS PER JOINT; SPLITTING, CRACKING, DAMAGED WOOD; 4) GROUND TO 4TH FLOOR, MULTIPLE LOCATIONS, BEAMS, PULLING OUT OF FIRE CUTS, IMPROPERLY SUPPORTED AT FIRE CUTS, SQUARE FIRE CUTS USED TO CONNECT BEAMS TO COLUMNS; 5) GROUND TO 4TH FLOOR, MULTIPLE LOCATIONS, LEDGER BEAMS, FASTENED TO THE BUILDING EXTERIOR WALLS WITH EXPANSION TYPE BOLTS; 6) GROUND TO 4TH FLOOR, MULTIPLE LOCATIONS, STAIR TREADS, WINDERS, FACE NAILED ONLY; 7) ENTIRE STRUCTURE, WEAK, UNSTABLE; 8) OBTAIN PLANS AND PERMIT FOR REPLACEMENT. | 1967 N DAYTON ST | PERIODIC | FAILED | View |
PROVIDE SIDEWALK SHED F/PROTCT | IMMEDIATELY PROVIDE SIDEWALK SHED FOR PROTECTION OF PROPERTY AND PASSERSBY FROM UNSAFE CONDITIONS, AS FOLLOWS: 1) WEST ELEVATION, MIDDLE OF THE BUILDING, ABOVE ENTRANCE TO 1967 N DAYTON ST, LARGE LIMESTONE MASONRY, SPLIT, SAGIING, SHIFTING, OVER PUBLIC WAY; 2) WEST ELEVATION, MIDDLE OF THE BUILDING, ABOVE ENTRANCE TO 1967 N DAYTON ST, 2ND TO 3RD FLOORS, WASHED OUT MORTAR, SPALLING MASONRY, OVER PUBLIC WAY; 3) WEST ELEVATION, ABOVE 2ND STORY WINDOWS, 2ND AND 3RD WINDOWS FROM NORTH-WEST CORNER'S BAY WINDOWS, LARGE LIMESTONE MASONRY, SEVERELY CRACKED, SPLITING, SHIFTING, SPALLING, OVER PUBLIC WAY; 4) WEST ELEVATION, NORTH-WEST CORNER, ABOVE STOREFRONT, MASONRY, SEVERE BULGING, SHIFTING, STEP FRACTURES, LARGE LIMESTONES, SPLIT, BULGING, OVER PUBLIC WAY. | 1967 N DAYTON ST | PERIODIC | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | 1967 N DAYTON ST, BASEMENT TO 4TH FLOOR, INTERIOR STAIRWAY, MULTIPLE LOCATIONS, STAIR TREADS, DAMAGED, SPLIT, WORN OUT, SECTIONS OF STAIR NOSING, MISSING. OBTAIN PERMIT FOR REPAIRS. | 1967 N DAYTON ST | PERIODIC | FAILED | View |