The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR EXTERIOR WALL | EXTERIOR WALL REPAIR-(1) SOUTH ELEVATION LINTELS RUSTED CAUSING DAMAGE TO SURROUNDING BRICK AND TERRA COTTA, SOME PIECES HAVE SPALLED HAVE SPALLED OFF OR REMOVED, AT VARIOUS LOCATIONS, (2) SOUTH ELEVATION OVER MAIN ENTRANCE AT 2ND-4TH FLOOR CRACKING OF BRICK AND SILLS (3) SOUTH ELEVATION SEVERE WASHED OUT MORTAR (4) EAST ELEVATION CONCRETE SPALLING EXPOSED REBAR, (5) SEVERE WASHED OUT MORTAR ON EAST ELEVATION, (6) EAST ELEVATION TERRA COTTA WATER MARK BAND SPALLING ABOVE 2ND FLOOR WINDOW HEADS (7) NORTH ELEVATION CONCRETE OLD PATCH REPAIRS FAILING, CRACKING AT VARIOUS LOCATIONS, (8) NORTH ELEVATION SEVERE WASHED OUT MORTAR, (9) AT NORTH ELEVATION AT CONCRETE TOWER (STAIR) PARAPET BULGING AT CORNERS TOWER LOCATED IN CENTER OF BUILDING, (10) CENTER AREA/LIGHT WELL OF BUILDING WHERE METAL STACK IS LOCATED SEVERE WASHED OUT MORTAR, SPALLING BRICK, (11) WEST ELEVATION BRICK PIERS CRACKS TEMP REPAIRS, SEVERE WASHED OUT MORTAR, (12) WEST ELEVATION NEAR SOUTHWEST CORNER LINTELS BOWING, RUSTED LARGE WIDOW JOINTS | 564 W RANDOLPH ST | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE CAR NUMBER ON ALL HOISTWAY ENTRANCES AT ALL LOBBIES | 564 W RANDOLPH ST | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | COORDINATE WITH PACKWAY ELEVATOR CO TO CONFIGURE THE PASSENGER ELEVATORS AND MASTER FIRE RECALL UTILIZING FEOKL KEYS AND KEY SWITCHES. | 564 W RANDOLPH ST | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | CONTACT THE CITY OF CHICAGO ELEVATOR BUREAU TO SCHEDULE FIREMANS SECURITY TESTING INCLUDING FAID RECALLS' | 564 W RANDOLPH ST | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | RECONFIGURE HITCH PLATE ARRANGEMENT TO BE UNDER CROSSHEAD. | 564 W RANDOLPH ST | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE TOE GUARD ON BOTTOM TERMINAL LANDING SILL | 564 W RANDOLPH ST | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | REMOVE SPRINKLERHEADS FROM OVERHEAD | 564 W RANDOLPH ST | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE FIRE EXTINGUISHER IN MACHINE ROOM | 564 W RANDOLPH ST | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | STENCIL(IDENTIFY) DISCONNECTS MACHINE, CONTROLLER, GOVERNOR, CROSSHEAD AND PIT EQUIPMENT | 564 W RANDOLPH ST | PERMIT | PASSED | View |
ARRANGE COMPLETED PERMIT INSP. | ARRANGE COMPLETE PERMIT INSPECTION CODE 13-176-310 | 564 W RANDOLPH ST | COMPLAINT | PASSED | View |
PROVIDE | PROVIDE TWO SEPARATE KITCHEN EXHAUST HOODS ONE FOR CHARBROILER AND ONE FOR GREASE COOKING COMBINING THE TWO IS DANGEROUS AND HAZARDOUS | 564 W RANDOLPH ST | COMPLAINT | PASSED | View |
PROVIDE | PROVIDE CANOPY-TYPE COMMERCIAL COOKING HOODS SHALL EXHAUST A MINIMUM QUANTITY OF AIR CODE CHARBROILERS-QUANTITY OF AIR 300 X HORIZONTAL SURFACE AREA DEEP FAT FRYERS-QUANTITY OF AIR 150 X HORIZONTAL SURFACE AREA YOUR EXHAUST FAN IS ONLY 8137 | 564 W RANDOLPH ST | COMPLAINT | PASSED | View |
ARRANGE FOR RE-INSPECTION | NEED PRV ON STULZ UNIT | 564 W RANDOLPH ST | PERMIT | PASSED | View |
ARRANGE PERMIT INSP. | 564 W RANDOLPH ST | PERMIT | PASSED | View | |
INSTALL VENT/AS SHOWN ON PLANS | NUMEROUS ITEMS TO COMPLETE (FINAL APPL) | 564 W RANDOLPH ST | PERMIT | PASSED | View |
ARRANGE FOR RE-INSPECTION | MECHANICAL JOINTS,WRONG MECHANICAL CONTRACTOR ON PERMIT | 564 W RANDOLPH ST | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | EXTEND HANDRAIL ON LADDER GOING TO ROOF ACCESS DOOR | 564 W RANDOLPH ST | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PLACE METAL TUBE AROUND LADDER TO PREVENT FALL | 564 W RANDOLPH ST | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | DO FULL INSPECTION OF FORE SERVICE FLOW SWITCH IN PEOPLE'S APARTMENT | 564 W RANDOLPH ST | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ADD SWITCH TO ACCESS DOOR AND TIE TO SAFETY CIRCUIT | 564 W RANDOLPH ST | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ADD CATWALK TO TOP OF ELEVATOR SHAFT WITH LIGHT | 564 W RANDOLPH ST | PERMIT | PASSED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF THE BUILDING - NO RESPONSE, UNVERIFIED DETECTORS AND CONDITIONS. NO ENTRY FOR 2016 ANNUAL INSPECTION. | 564 W RANDOLPH ST | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | DRYWALL ALL ENTRANCES WITH 2 HOUR FIRE RATING. | 564 W RANDOLPH ST | PERMIT | PASSED | View |
REPLCE WINDOW PANES, PLEXGLAS | SOUTH ELEVATION, 1ST FLOOR CH DISTILLERY BAR - EXTERIOR GLASS PANEL BOARDED UP. | 564 W RANDOLPH ST | COMPLAINT | CLOSED | View |
MAINTAIN WINDOW | SOUTH ELEVATION, 1ST FLOOR CH DISTILLERY BAR - STOREFRONT FRAME BENT, METAL FRAME AROUND WINDOW - BOLTS AT COLUMN MISSING. | 564 W RANDOLPH ST | COMPLAINT | CLOSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | FIX INSPECTION BOX ON TOP OF ELEVATORS | 564 W RANDOLPH ST | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | FIX DOOR RESTRICTOR | 564 W RANDOLPH ST | PERMIT | PASSED | View |
PRV SOFT-SODER/FUSABLE PLUG | VENT LINE NEEDS TO BE BRAZED | 564 W RANDOLPH ST | PERIODIC | FAILED | View |