Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
DEMO DEBRIS | WEST ELEVATION / BROKEN CONCRETE AND DIRT - STORED UNDER FRONT PORCH. | 11727 S CHURCH ST | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | NORTH ELEVATION / 4 FOOT X 6 FOOT 2 STORY WOOD PORCH / COLUMNS - ERECTED ON CONCRETE SLAB. FOUNDATION STATUS - UNKNOWN. SLAB HAS CRACKS AT VARIOUS LOCATIONS. 2X8 JOISTS SPACED 22 INCHES ON CENTER. JOISTS HAVE 90 * JOIST HANGERS WITH INSUFFICIENT AMOUT OF NAILS INSTALLED INTO HANGERS. ENTIRE 2ND FLOOR DECK SYSTEM HASS COLLAPSED TO THE GROUND. STAIR STRINGERS - FASTENED WITH NAILS ONLY AT UPPER CONNECTIONS. GUARDRAILS - FASTENED TO EXTERIOR WALL WITH NAILS ONLY. 4X4 GUARDRAIL POSTS - FASTENED TO DECKING WITH TOENAILS ONLY. WEST ELEVATION / 1 STORY PORCH WITH AWNING / 4X4 COLUMNS - ERECTED ON SOIL WITH CONRETE POURED AROUND BASES. FOUNDATION STATUS - UNKNOWN. PORCH DECK - LEANING UP TO 1 1/2 INCHES OUT OF LEVEL. STAIRS LEANING - OUT OF LEVEL AS WELL. GUARDRAILS - MEASURE ONLY 33 INCHES HIGH AND ARE FASTENED WITH NAILS ONLY. PLANS AND PERMIT REQUIRED TO REPLACE EXTREMELY DANGEROUS AND HAZARDOUS PORCHS. SUBJECT TO FIELD INSPECTION AND APPROVAL. | 11727 S CHURCH ST | COMPLAINT | FAILED | View |
RMV PLBFIX INSTALLD W/0 PERMIT | ATTIC, KITCHEN SINK BATH TOILET AND LAVATORY REMOVE | 11727 S CHURCH ST | COMPLAINT | FAILED | View |
DEMO DEBRIS | REAR YARD CONSTRUCTION DEBRIS | 11727 S CHURCH ST | COMPLAINT | FAILED | View |
LIGHT AND VENT | BASEMENT DWELLING UNIT / GLASS BLOCK WINDOWS HAVE 8 X 16 INCH VENTS. | 11727 S CHURCH ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | NORTH ELEVATION / 2ND FLOOR WALL - BULGING OUTWARD. | 11727 S CHURCH ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT, 1ST FLOOR AND 2ND FLOOR OR RESTORE THE BUILDING TO THE ORIGINAL STATE. | 11727 S CHURCH ST | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | REMOVE ALL PARTITIONS AND FIXTURES INCLUDING PLUMBING AND ELECTRIC INSTALLED IN THE BASEMENT AND 2ND FLOOR WITHOUT PERMIT. | 11727 S CHURCH ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | FRONT INTERIOR STAIRWAYS AND REAR ENCLOSED PORCH / SMOKE DETECTORS - MISSING. | 11727 S CHURCH ST | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | INTERIOR STAIRWAYS - STAIRWAY WIDTHS - MEASURE ONLY 31 ICHES WIDE AND ARE NOT AT LEAST 36 INCHES WIDE. STAIRS HAVE VARIOUS RISER HEIGHTS, | 11727 S CHURCH ST | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | NORTH ELEVATION / 2ND FLOOR DOOR - COVERED WITH PLYWOOD BECAUSE OF PORCH COLLAPSE. | 11727 S CHURCH ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR ENCLOSED PORCH / STAIR TREADS - LOOSE AND UNSTABLE. 2ND FLOOR DECK - LEANING UP TO 1 1/2 INCHES OUT OF LEVEL. REAR 2ND FLOOR PORCH PACKED WITH BOXES AND BINS AND HOUSHOLD GOODS.PLANS AND PERMIT TO REPLACE REAR WNCLOSED PORCH. | 11727 S CHURCH ST | COMPLAINT | FAILED | View |
CEILING HEIGHT - 7' | 2ND FLOOR CEILING HEIGHT MEASURES ONLY 80 INCHES. DOORWAY TO KITCHEN MEASURES ONLY 71 INCHES HIGH. | 11727 S CHURCH ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY FRUSED AT 2 | 11727 S CHURCH ST | COMPLAINT | FAILED | View |
REPAIR GUTTER & DOWNSPOUT | SOUTH AT EAST DOWNSPOUT MISSING | 11727 S CHURCH ST | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | 2 NORTH AT WEST CRACKED WINDOW | 11727 S CHURCH ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | NORTH AT WEST CRACKED WINDOW | 11727 S CHURCH ST | COMPLAINT | FAILED | View |
POST OWNER INFO ON ABDN BLDG | POST ID | 11727 S CHURCH ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | WEST STAIR ANCHOR LEDGER | 11727 S CHURCH ST | COMPLAINT | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | GARAGE SERVICE DOOR BROKEN OPEN | 11727 S CHURCH ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | NOETH STAIRS HEDGES STRINGERS JOIST, VAIL NOT ANCHORED. UNDERSIZED RAIL NOT 42" STINGER | 11727 S CHURCH ST | COMPLAINT | FAILED | View |
REPAIR / REBUILD SHED | GARAGE ROTTED RAFTERS EAVES FRAMING, GARAGE LEANING SEVERLY OUT OF PLUMB, IN DANGER OF COLLAPSE | 11727 S CHURCH ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | NORTH STAIRS IMPROPER FOOTINGS, JOIST MISSING HANGERS IMPROPER RAILING SYSTEM, ALSO FRONT RAILS, FRONT BROKEN TREADS | 11727 S CHURCH ST | COMPLAINT | FAILED | View |
INSTALL EXTRA SMOKE DETECTORS | NO SMOKE FRONT AND REAR STAIRWELL | 11727 S CHURCH ST | COMPLAINT | FAILED | View |
CONTRARY TO ORIGINAL PLAN | ATTIC NOW BEING USED AS A DWELLING UNIT | 11727 S CHURCH ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | NO PLANS OR PERMITS FOR ATTIC | 11727 S CHURCH ST | COMPLAINT | FAILED | View |
1-HR STAIR ENCLOSURE, <3 STORY | STAIRWELL NOT 1 HOUR | 11727 S CHURCH ST | COMPLAINT | FAILED | View |
1HR SEP-D.U. AND REST OF BLDG | SEPARATION NOT 1 HOUR | 11727 S CHURCH ST | COMPLAINT | FAILED | View |
III-B AND IV-A FIRE RESISTANCE | WOOD LATH AND PLASTER | 11727 S CHURCH ST | COMPLAINT | FAILED | View |
REMOVE GAS LINE AND JET | ATTIC REMOVE GAS LINE FOR COOKING STOVE | 11727 S CHURCH ST | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | NO CARBON MONOXIDE DETECTOR ATTIC AND 1ST FLOOR | 11727 S CHURCH ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO BASEMENT TO VERIFY DETECTORS AND OCCUPANCY | 11727 S CHURCH ST | COMPLAINT | FAILED | View |
UNAPPROVED HEATING DEVICE | 2ND FLOOR DWELING UNIT / USING COOKING STOVE AS A HEATING DEVICE. | 11727 S CHURCH ST | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | 2ND FLOOR DWELLING UNIT / CARBON MONOXIDE DETECTOR - MISSING. | 11727 S CHURCH ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | REAR ENCLOSED PORCH AND ILLEGAL 2ND FLOOR DWELLING UNIT / SMOKE DETECTORS - MISSING. | 11727 S CHURCH ST | COMPLAINT | FAILED | View |
HEAT UNIT ADEQUATELY | 2ND FLOOR DWELLING UNIT / ROOM TEMPERATURES : BEDROOM 1 66F, AT 3:25 PM, BEDROOM 2 65F AT 3:30 PM. HEATING SYSTEM IS OFF AT TIME OF INSPECTION NO HEAT PROVIDED. | 11727 S CHURCH ST | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | NORTH AND EAST ELEVATIONS / GARBAGE BAGS, STORAGE BINS AND JUNK - STORED. | 11727 S CHURCH ST | COMPLAINT | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | BUILDING AT VARIOUS LOCATIONS / SCREENS - MISSING. | 11727 S CHURCH ST | COMPLAINT | FAILED | View |