Chicago Building Violations Data: 109 Violations
Violation Inspector Comments Address Category Status View
MAINTAIN OR REPAIR HYDRO ELEVA ELEVATORS ARE BEING MODERNIZED IN CONJUCTION WITH PERMIT #100749220. UPON COMPLETION FIREMANS SERVICE RECALL TEST WITH FAID AND EMERGENCY POWER TESTING MUST BE SCHEDULED, PERFORMED, AND ACCEPTED TO FINAL PERMITS 321 N CLARK ST PERMIT PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA REMOVE SHEET METAL SCREWS FROM TOP OF THE HOISTWAY 321 N CLARK ST PERMIT PASSED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE SIGNAGE ON WALL IN PIT AND CAR #10 TOE GUARD ALSO CHAIN WITH SIGN 321 N CLARK ST PERMIT PASSED View
MAINTAIN OR REPAIR ELECT ELEVA CANTER LEDGES IN HOISTWAY 70 DEG. 321 N CLARK ST PERMIT PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA PROVIDE 10 FOOT CANDLES OF ILLUMINATION THROUGHOUT PIT. 321 N CLARK ST PERMIT PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA PROVIDE 19 FOOT CANDLES OF ILLUMINATION THROUGHOUT MACHINE ROOM. 321 N CLARK ST PERMIT PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA REMOVE SPRINKLER AND PIPES FROM MACHINE ROOM 321 N CLARK ST PERMIT PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA PROVIDE A DEEP CATCH PAN UNDER THE PIPES THAT ARE OVER THE CONTROLLER AND DISCONNECTS. DRAIN TO OUTSIDE OF MACHINE ROOM 321 N CLARK ST PERMIT PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA ID FEED LOCATION FOR MAIN LINE AND 110 DISCONNECTS 321 N CLARK ST PERMIT PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA PROVIDE A GFI OUTLET ALONG SIDE CONTROLLERS 321 N CLARK ST PERMIT PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA PROVIDE A VERIFICATION LIGHT AND ALARM FOR THE PHONE LINES 321 N CLARK ST PERMIT PASSED View
MAINTAIN OR REPAIR ELECT ELEVA #3 RELOCATE PIT LIGHT SWITCH INSIDE PIT 321 N CLARK ST PERMIT PASSED View
MAINTAIN OR REPAIR ELECT ELEVA #8 PROPERLY LABEL ALL DISCONNECTS AND SOURCE LOCATION CRKT 321 N CLARK ST PERMIT PASSED View
MAINTAIN OR REPAIR ELECT ELEVA #8 LABEL ALL MACHINE ROOM DOORS & PIT DOORS 321 N CLARK ST PERMIT PASSED View
MAINTAIN OR REPAIR ELECT ELEVA TWO POSITION KEY SWITCH REQUIRED AT LOBBY PANEL 321 N CLARK ST PERMIT PASSED View
MAINTAIN OR REPAIR ELECT ELEVA SHOW OUTSIDE ELEVATOR ON DIAGRAM AT LOBBY PANEL 321 N CLARK ST PERMIT PASSED View
MAINTAIN OR REPAIR ELECT ELEVA REVIEWED HIGH RISE PIT ACCESS, BANQUET HALL HAS WHEELED DECORATIVE CURTAINED WALL FIXTURE RESTRICTING SAFE AND CONVENIENT ACCESS; PROVIDE LIGHTING, CLEAR AND CONSPICUOUS SIGNAGE ON FRAMES, AND INSTRUCTIONS FOR ELEVATOR TECHNICIANS. TO BE RE-INPECTIONM AND RE-VISITED. 321 N CLARK ST PERMIT PASSED View
MAINTAIN OR REPAIR ELECT ELEVA #9 LABEL ALL DISCONNECTS IN MACHINE ROOMS 321 N CLARK ST PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA #9 PATCH HOLES IN MACHINE ROOM AND HOISTWAY 321 N CLARK ST PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA #19 PATCH HOISTWAY 321 N CLARK ST PERMIT PASSED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE ELEVATOR CONTROL PANEL IN LOBBY PURSUANT TO THE CITY OF CHICAGO CODE 321 N CLARK ST PERMIT PASSED View
MAINTAIN OR REPAIR ELECT ELEVA #8 REMOVE CURTAINS IN FROM PIT DOORS & LIGHTS AND EMERGENCY EVAC DOORS, MUST HAVE SAFE ACCESS & EGRESS FROM PITS 321 N CLARK ST PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA #8 PATCH HOISTWAY AS NEEDED 321 N CLARK ST PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA #8 110 HEAVY DUTY DISCINNECT 321 N CLARK ST PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA #9 UNINTENDED TESTS 321 N CLARK ST PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE DRIP PANS UNDER ALL PLUMBING IN THE MACHINE ROOMS 321 N CLARK ST PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA CAULK NEW DOOR JAMBS AS NEEDED 321 N CLARK ST PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE 110V HEAVY DUTY DISONNECTS 321 N CLARK ST PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE FAULT ALARM TO INDICATE POWER FAILURE OR PRESSURE LOSS IN EMERGENCY BRAKE AIR LINES IN THE HIGH RISE 321 N CLARK ST PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA #9 INSTALL MORE LIGHT IN MACHINE ROOM 321 N CLARK ST PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA #9 110 DISCONNECT GROUND WIRE 321 N CLARK ST PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA #3 ADD ADDITIONAL GFI OUTLETS IN PIT 321 N CLARK ST PERMIT PASSED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE GFCI CONVENIENCE OUTLETS IN ALL CONTROLLER SPACES 321 N CLARK ST PERMIT PASSED View
MAINTAIN OR REPAIR ELECT ELEVA #9 PROVIDE GFI OUTLETS IN MACHINE ROOM 321 N CLARK ST PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA #9 ASCENDING CAR TEST 321 N CLARK ST PERMIT FAILED View
POST APPROVED OCCUPANCY CARD SUBMIT AND OBTAIN A NEW OCCUPANCY PLACARD FOR MAIN DINING ROOM. PLACARD ISSUED AS A DUPLICATE FOR 182 PEOPLE DOES NOT MATCH CURRENT LAYOUT OR CALCULATIONS. 321 N CLARK ST COMPLAINT CLOSED View
POST APPROVED OCCUPANCY CARD SUBMIT AND OBTAIN A NEW OCCUPANCY PLACARD FOR MAIN DINING ROOM. PLACARD ISSUED AS A DUPLICATE FOR 182 PEOPLE DOES NOT MATCH CURRENT LAYOUT OR CALCULATIONS. 321 N CLARK ST PERIODIC FAILED View
ARRANGE COMPLETED PERMIT INSP. 321 N CLARK ST PERMIT PASSED View
ADDITIONAL EXIT PROVIDE ADDITIONAL MEANS OF EGRESS AT DINING ROOM (REAR 32" STAIRS LEADING TO GARAGE IS NOT CODE COMPLIANT, ORIGINAL STAIRS). OCCUPANCY EXCEEDS 50PPL, 44" MINIMUM WIDTH STAIRS REQUIRED; CBC SECTION 10(13-160-220) 321 N CLARK ST PERIODIC PASSED View
UNINTERRUPTED EXIT AT GRADE PROVIDE UNINTERRUPTED EGRESS AT WEST STAIRS TO CLARK ST (NEED 2ND EGRESS FOR DINING ROOM AND PATIO, 289PPL TOTAL OCCUPANCY). STAIRS BEING REPAIRED. 321 N CLARK ST PERIODIC PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA PROVIDE FIRE EXTINGUSHER IN MACHINE ROOM CAR # 24 321 N CLARK ST PERMIT PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA PROVIDE MACHINE ROOM DOOR SIGNAGE CAR # 24 321 N CLARK ST PERMIT PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA POPERLY LABEL DISCONNECTS CAR #24 321 N CLARK ST PERMIT PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA CONTACT THE ELEVATOR BUREAU OF THE CITY OF CHICAGO UPON COMPLETION OF MODERNIZATION TO SCHEDULE RE-INSPECTION AND FIRE RECALL TESTING 321 N CLARK ST PERMIT PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA PROVIDE ADDITIONAL LADDER CAR # 24 321 N CLARK ST PERMIT PASSED View
STOP NUISANCE TO NEIGHBORS STOP NUISANCE TO NEIGHBOR (7-[8-010)(7-28-030,2-28-020,7-28-060 NOTICE TO ABATE NUISANCE TO NEIGHBORS EXHAUST FOR 2 KITCHEN HOODS ARE VENTED INTO A UNDERGROUND AREA, PARKING FACILITY & LOADING DOCK, CAUSING A NUISANCE 4(7-26-010) AND 4(7-28-080) 321 N CLARK ST COMPLAINT FAILED View
ARRANGE COMPLETED PERMIT INSP. 321 N CLARK ST PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA LABEL ALL EQUIPMENT, DISCONNECTS WITH SOURCE FEED 321 N CLARK ST PERMIT PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA PATCH AND FIRECAULK ALL GAPS IN HOISTWAY AND MACHINE ROOM 321 N CLARK ST PERMIT PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA INSTALL SELF-CLOSER ON PIT ACCESS 321 N CLARK ST PERMIT PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA REMOVE TEMPORARY DRAIN HOSES IN MACHINE ROOM OR PIPE SOLID 321 N CLARK ST PERMIT PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA INSTALL FASCIA FROM 1 - 2 321 N CLARK ST PERMIT PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA INSTALL ESCAPE PANEL SWITCH 321 N CLARK ST PERMIT PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA INSTALL SMOKE DETECTOR ON LOWER LANDING 321 N CLARK ST PERMIT PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA TIE CAR IN TO LOBBY FIRE PANEL AND TEST ALL FIRE RELATED RECALL FUNCTIONS 321 N CLARK ST PERMIT PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA PROVIDE LOBBY FIRE PANEL WITH A GRAPHIC DISPLAY OF LOCATION OF #23 CAR 321 N CLARK ST PERMIT PASSED View
MAINTAIN OR REPAIR ELECT ELEVA #3 CAB FLOOR 321 N CLARK ST PERMIT PASSED View
MAINTAIN OR REPAIR ELECT ELEVA #3 SIGNAGE ON PIT DOOR 321 N CLARK ST PERMIT PASSED View
MAINTAIN OR REPAIR ELECT ELEVA #3 SELF CLOSER ON PIT DOOR 321 N CLARK ST PERMIT PASSED View
MAINTAIN OR REPAIR ELECT ELEVA #19 INSTALL PIT LIGHT'S , GFI OUTLETS , 321 N CLARK ST PERMIT PASSED View
MAINTAIN OR REPAIR ELECT ELEVA #19 INSTALL HOISTWAY FASCIA AS NEEDED 321 N CLARK ST PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA PROVIDE LOW-OVERHEAD SIGNAGE IN HOISTWAY 321 N CLARK ST PERMIT PASSED View
OBSTRUCTIONS IN EXIT WAY REMOVE PATIO COUCHES AND CANVAS OBSTRUCTING REAR EXIT DOOR AT KITCHEN. 321 N CLARK ST PERIODIC PASSED View
MAINTAIN MECH. VENT SYSTEM MAINTAIN EQUIPMENT GARAGE EXHAUST FAN NOT WORKING 18-28-102.3 321 N CLARK ST COMPLAINT FAILED View
OPEN TYPE VIOLATION (VT 2032) MATERIALS PERFORMANCE GARAGE EXHAUST FANS NOT WORKING PROPERLY BELTS BROKEN/MISSING 1(13-16-060) EQUIPMENT APPEARS TO BE BEYOND REPAIR 321 N CLARK ST COMPLAINT FAILED View
ARRANGE ANNUAL INSP. ARRANGE FOR ANNUAL INSPECTION 13-20-290, 13-20-020 321 N CLARK ST COMPLAINT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE FAID'S AND SCHEDULE FIRE SERVICE RECALL AND EMERGENCY POWER TESTING UPON COMPLETION OF ALL MODERNIZED ELEVATORS AND COMPLIANCE OF ALL OTHER VIOLATIONS 321 N CLARK ST PERMIT PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA PROVIDE A DEEP CATCH PAN UNDER THE HEAT PUMP UNIT. DRAIN TO THE OUTSIDE OF THE MACHINE ROOM. 321 N CLARK ST PERMIT PASSED View
MAINTAIN OR REPAIR ELECT ELEVA ID.AND BRAILLE ON CARS #19 & #20 LOWER LEVELS 321 N CLARK ST PERMIT PASSED View
ARRANGE COMPLETED PERMIT INSP. 321 N CLARK ST PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE GFCI CONVENEINCE OUTLETS IN ALL CONTROL, MACHINE, AND PIT EQUIPMENT SPACES THROUGH OUT BUILDING ASSOCIATED WITH THE MODERNIZATION. 321 N CLARK ST PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE MECHANICAL PROTECTION ON ALL LIGHT BULBS IN ALL CONTROL, MACHINE, AND PIT EQUIPMENT SPACES THROUGH OUT BUILDING ASSOCIATED WITH THE MODERNIZATION. 321 N CLARK ST PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE THE PROPER LIGHTING (ADDITIONAL FIXTURES) IN ALL CONTROL, MACHINE, AND PIT EQUIPMENT SPACES THROUGH OUT BUILDING ASSOCIATED WITH THE MODERNIZATION. 321 N CLARK ST PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA REPAIR ELEVATOR #18 AND RESCHEDULE ACCEPTANCE TESTING;TO INCLUDE CAR & COUNTER WEIGHT GOVERNOR SAFETY, UNITENTIONAL MOTION EMERGENCY BRAKE DOWN, 125% BRAKE TEST, DOWN ETS & NTS..... 321 N CLARK ST PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA DO NOT USE ELEVATOR # 18 UNTIL RE-INSPECTION AND ACCEPTANCE TESTING IS SATIFACTORLY COMPLETED. 321 N CLARK ST PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA INSTALL LOBBY PANEL(ELEVATOR CONTROL PANEL) TO INCLUDE ALL ELEVATORS IN THE BUILDING #1-#24 321 N CLARK ST PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE FIRE SERVICE KEY BOXES ADJACENT TO ALL PHASE I KEY AND AT THE LOBBY ELEVATOR CONTROL PANEL 321 N CLARK ST PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE DIAGRAMIC DEPICTION OF BUILDING INCLUDING THE LOCATION OF ALL ELEVATORS AT ELEVATOR CONTROL PANEL 321 N CLARK ST PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA COMPLETE ALL ESCUSSIONS AND ACCESS HOLES ON ALL HOISTWAY DOORS OF ALL ELEVATORS 321 N CLARK ST PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA MACHINE ROOM LIGHTING 321 N CLARK ST PERMIT PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA GFCI OUTLETS IN MACHINE ROOM 321 N CLARK ST PERMIT PASSED View
MAINTAIN OR REPAIR ELECT ELEVA REMOVE FIRE SPRINKLERS AND ALL RELATED PLUMBING FROM ALL MACHINE ROOMS 321 N CLARK ST PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE SAFE AND CONVENIENT ACCESS TO MACHINE, CONTROLLER, AND ALL CONTROL SPACES 321 N CLARK ST PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE MECHANICAL PROTECTION FOR LIGHT BULBS IN MACHINE ROOMS 321 N CLARK ST PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE GFCI CONVENIENCE OUTLETS IN CONTROLLER SPACES 321 N CLARK ST PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE FAID'S AND SCHEDULE FIRE SERVICE RECALL AND EMERGENCY POWER TESTING UPON COMPLETION OF ALL MODERNIZED ELEVATORS AND COPLIANCE OF ALL OTHER VIOLATIONS 321 N CLARK ST PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA SUPPORT/SECURE BLACK PIPE ROUTED AJACENT TO THE ACCESS POINT FOR CONTROLLERS #5, #6, AND #7 321 N CLARK ST PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA #11- NOT READY FOR INSPECTION 321 N CLARK ST PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA #11- REPAIR OR REPLACE COUNTERWEIGHT SAFETY ROD 321 N CLARK ST PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA #11- RE-TEST COUNTWEIGHT SAFETY TEST 321 N CLARK ST PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA #11- PROVIDE SIGNAGE ON WALL IN PIT / CAR #10 TOE GUARD ALSO CHAIN WITH SIGN 321 N CLARK ST PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA #11- INSTALL PIT BELL 321 N CLARK ST PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA #17- FINISH CAB FLOOR 321 N CLARK ST PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA #17- REPAIR EMERGENCY PHONE 321 N CLARK ST PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA #17- CALK NEW DOOR JAMBS AS NEEDED 321 N CLARK ST PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA #17- EMERGENCY LIGHTS 321 N CLARK ST PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA #17- WORKING PI'S INSIDE CAR 321 N CLARK ST PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA #17- 110 HEAVY DUTY DISONNECT 321 N CLARK ST PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA #17- PERFORM CAR,COUNTERWEIGHT DROP TEST CWT BUFFER TEST 321 N CLARK ST PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA FINISH CAB FLOORS 321 N CLARK ST PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA INSTALL PIT BELLS FOR ALL ELEVATORS 321 N CLARK ST PERMIT PASSED View
ARRANGE COMPLETED PERMIT INSP. ARRANGE INSPECTION (13-12-100,13-176-310,13-184-140,18-28-106.1) 321 N CLARK ST COMPLAINT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE ADDITIONAL LIGHTING AND MECHANICAL PROTECT ALL LIGHT BULBS IN MACHINE ROOMS 321 N CLARK ST PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA #22: REMOVE WIRE FROM TOP OF HOISTWAY 321 N CLARK ST PERMIT PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA BOX OFF PIPES IN THE HOISTWAY 321 N CLARK ST PERMIT PASSED View
MAINTAIN OR REPAIR ELECT ELEVA ADDRESS MONITORING OF THE COMPRESSORS REQUIRED TO OPERATE THE EMERGENCY BRAKING. INDICATION OF POWER LOSS 321 N CLARK ST PERMIT FAILED View
INSTALL EXIT SIGN ORIENT DIRECTION EXIT SIGNAGE ABOVE 6' WIDE DOUBLE DOORS AT WORK CAFE TO DIRECT EGRESS INTO LOBBY, AS SHOWN ON EGRESS PLANS PROVIDED FOR OCCUPANCY PLACARDS. 321 N CLARK ST PERIODIC FAILED View
INSUFFICIENT MEANS OF EGRESS PANIC HARDWARE REQUIRED AT STAIR ACCESS DOORS (31ST AND 32ND FLOORS). PANIC HARDWARE REQUIRED AT 31ST FLOOR WORK CAFE NORTHEAST EXIT DOOR. 321 N CLARK ST PERIODIC FAILED View
ARRANGE PREMISE INSPECTION NO ENTRY FOR ANNUAL INSPECTION. DENIED ENTRY FELT UNSAFE LETTING INSPECTOR IN CALL SUPERVISOR AT 312-743-3559 OR 312-743-3610 321 N CLARK ST PERIODIC FAILED View