The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
| Violation | Inspector Comments | Address | Category | Status | View |
|---|---|---|---|---|---|
| CARPETING | INTERIOR STAIR CARPET UNSANITARY | 5401 S ELLIS AVE | PERIODIC | PASSED | View |
| REPAIR CORNICE | CORNICE WASHED MORTAR JOINTS 1ST,3RD SCATTERED LOCATION FRONT | 5401 S ELLIS AVE | COMPLAINT | FAILED | View |
| REPAIR WINDOW SILLS | WINDOW SILLS WASH OUT MORTAR JOINTS REAR | 5401 S ELLIS AVE | COMPLAINT | FAILED | View |
| REPAIR EXTERIOR WALL | EXTERIOR WALL FRACTURES AT MORTAR JOINTS FRONT, WASHED OUT MOTAR JOINTS REAR | 5401 S ELLIS AVE | COMPLAINT | FAILED | View |
| REPAIR PORCH SYSTEM | REAR PORCH MISSING HATCH COVER | 5401 S ELLIS AVE | COMPLAINT | FAILED | View |
| OBSTRUCTIONS IN EXIT WAY | REAR BURGLER GATES ON APARTMENT DOORS | 5401 S ELLIS AVE | COMPLAINT | FAILED | View |
| ABANDONED REFRIGERATOR | REAR PORCH REFRIGERATORS | 5401 S ELLIS AVE | COMPLAINT | FAILED | View |
| DEBRIS, EXCESSIVE | REAR PORCH REFRIGERATORS AND MICROWAVE | 5401 S ELLIS AVE | COMPLAINT | FAILED | View |
| ARRANGE PREMISE INSPECTION | NO ENTRY TO INTERIOR | 5401 S ELLIS AVE | COMPLAINT | FAILED | View |
| REPAIR WINDOW SILLS | REAR / WINDOW SILLS - OPEN MORTAR JOINT . | 5401 S ELLIS AVE | PERIODIC | FAILED | View |
| REPAIR GUTTER & DOWNSPOUT | SOUTH ELEVATION , GUTTERS AND DOWNSPOUTS RUSTED , FLAKING PAINT , LEAKING AT JOINTS . | 5401 S ELLIS AVE | PERIODIC | FAILED | View |
| ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - NO RESPONSE, UNVERIFIED DETECTORS AND CONDITIONS. | 5401 S ELLIS AVE | PERIODIC | FAILED | View |
| FILE BLDG REGISTRATION | BUILDING - NOT REGISTERED 2016 YEAR . | 5401 S ELLIS AVE | PERIODIC | FAILED | View |
| STOP/REMOVE NUISANCE | NORTH AND EAST ELEVATION , PHONE AND CABLE LINES , LOOSE , HANGING , BROKEN AND LOOSE RACEWAYS , OPEN CABINETS , ENTANGLEMENT HAZARD . | 5401 S ELLIS AVE | PERIODIC | FAILED | View |
| REPAIR CORNICE | WEST ELEVATION LIMESTONE AND BRICK CORNICE , OPEN MORTAR JOINTS , WASHED OUT MORTAR . | 5401 S ELLIS AVE | PERIODIC | FAILED | View |
| MAINTAIN PROJECTIONS | WEST ELEVATION AT GRADE , IRON WINDOW GRATES RUSTED AND FLAKING PAINT . | 5401 S ELLIS AVE | PERIODIC | FAILED | View |
| REPAIR EXTERIOR DOOR | DOUBLE FRONT ENTRY DOORS , ROTTED , SAGGING , LOOSE GLASS , NOT FIT IN FRAMES , NOT SEALED FOR AIR INFILTRATION ,REQUIRE REPLACEMENT . | 5401 S ELLIS AVE | PERIODIC | FAILED | View |
| MAINTAIN WINDOW | BASEMENT WOOD WINDOW SCREEN FRAMES ALL ELEVATION ROTTED WITH FLAKING PAINT . | 5401 S ELLIS AVE | PERIODIC | FAILED | View |
| OBSTRUCTIONS IN EXIT WAY | MOST REAR EXIT DOORS - BURGLAR GATES. | 5401 S ELLIS AVE | PERIODIC | FAILED | View |
| REPAIR EXTERIOR DOOR, RESET | THREE NORTH PORCH ENTRY DOORS , SAGGING , LOOSE GLASS , NOT FIT IN FRAME . | 5401 S ELLIS AVE | PERIODIC | FAILED | View |
| POST OWNER/MANAGERS NAME/# | OWNERSHIP INFORMATION SIGN MISSING. | 5401 S ELLIS AVE | PERIODIC | FAILED | View |
| REPAIR INTERIOR WALLS/CEILING | CEILING WATER DAMAGES AT SKYLIGHT. | 5401 S ELLIS AVE | PERIODIC | FAILED | View |
| REPAIR INTERIOR WALLS/CEILING | CEILING WATER DAMAGES. | 5401 S ELLIS AVE | PERIODIC | FAILED | View |
| INSTALL SMOKE DETECTORS | BOILER ROOM MISSING SMOKE DETECTOR. | 5401 S ELLIS AVE | PERIODIC | FAILED | View |
| OBSTRUCTIONS IN EXIT WAY | APT DOORS BURGLAR BARS | 5401 S ELLIS AVE | PERIODIC | FAILED | View |
| REPAIR WINDOW SILLS | ALL ELEVATION WINDOW SILLS OPEN JOINTS | 5401 S ELLIS AVE | PERIODIC | FAILED | View |
| REPAIR PORCH SYSTEM | EAST PORCH TREAD WINDERS LOOSE,STRINGERS WOOD SPLIT,PERMIT FOR REPAIRS | 5401 S ELLIS AVE | PERIODIC | FAILED | View |
| REPAIR DOOR, INT. | APT. DOORS 8 AND 9 WOOD SPLIT | 5401 S ELLIS AVE | PERIODIC | FAILED | View |
| REPAIR INTERIOR STAIR SYSTEM | INTERIOR STAIR SECTION 1-12, RAILS LOOSE | 5401 S ELLIS AVE | PERIODIC | FAILED | View |
| CARPETING | ALL INTERIOR STAIRS CARPET LOOSE AND UNSANITARY | 5401 S ELLIS AVE | PERIODIC | FAILED | View |
| DEBRIS, EXCESSIVE | SOUTH AND EAST PORCH AREAS JUNK AND DEBRIS | 5401 S ELLIS AVE | PERIODIC | FAILED | View |
| KEEP FIXTUR CLEAN AND SANITARY | APT.5 BATHROOM TUB RUSTED, APT.20,KITCHEN SINK RUSTED | 5401 S ELLIS AVE | PERIODIC | FAILED | View |
| OBSTRUCTIONS IN EXIT WAY | REAR DOORS AND APARTMENT DOORS BURGLAR BARS | 5401 S ELLIS AVE | PERIODIC | PASSED | View |
| FILE BLDG REGISTRATION | NOT REGISTERED 2006 | 5401 S ELLIS AVE | PERIODIC | PASSED | View |
| REPAIR EXTERIOR DOOR | NORTH EXTERIOR DOOR BROKEN | 5401 S ELLIS AVE | PERIODIC | PASSED | View |
| SERVICE WALK, PASSAGE, AREAWAY | SERVICE WALK BROKEN CONCRETE | 5401 S ELLIS AVE | PERIODIC | PASSED | View |
| REPAIR PORCH SYSTEM | SOUTH WEST PORCH RAILS RAIL WALL SUPPORT STRINGER ROTTED DECKING TREADS RISERS WOOD SPLIT IMPROPER PICKETS SOUTH EAST PORCH RAILS DECKING STRINGER ROTTED EAST PORCH IMPROPER PICKETS RAILS ROTTED TREADS STRINGER 4X4 UPRIGHTS DECKING WOOD SPLIT AND WORN OUT RAIL WALL SUPPORT ROTTED | 5401 S ELLIS AVE | PERIODIC | PASSED | View |
| REPAIR EXTERIOR WALL | PORCH AREA JUNK AND DEBRIS | 5401 S ELLIS AVE | PERIODIC | PASSED | View |
| REPAIR LINTELS | LINTELS RUSTED AND SAGGING | 5401 S ELLIS AVE | PERIODIC | PASSED | View |
| PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND PERMITS FOR REPAIRS | 5401 S ELLIS AVE | PERIODIC | PASSED | View |
| REPAIR EXTERIOR DOOR FRAME | NORTH EXTERIOR DOOR FRAMES | 5401 S ELLIS AVE | PERIODIC | PASSED | View |
| REPAIR INTERIOR WALLS/CEILING | 5401 APARTMENT 2S KITCHEN BATHROOM WALL AND CEILING 5401 30-33 INTERIOR STAIR CEILING WATER DAMAGE | 5401 S ELLIS AVE | PERIODIC | PASSED | View |
| REPAIR DOOR HARDWARE | 5401-33 APARTMENT DOOR KNOB STRIP | 5401 S ELLIS AVE | PERIODIC | PASSED | View |
| REMV OBSTR FROM DRAINAGE SYSTM | 5401-33 APARTMENT BATHROOM SINK CLOG | 5401 S ELLIS AVE | PERIODIC | PASSED | View |
| REPLACE DEFECTIVE PLBG FIXTURE | 5401-30 APARTMENT BATHROOM TUB KITCHEN SINK PAINT CHIP | 5401 S ELLIS AVE | PERIODIC | PASSED | View |
| INT WALL/CEILING CHIP PLASTER | 5401-41 APARTMENT BATHROOM CEILING AND WALL LIVINGROOM PORCH SECTION 30 IMPROPER PICKETS DECKING TREADS STRINGER LOOSE AND SPLIT WORN OUT | 5401 S ELLIS AVE | PERIODIC | PASSED | View |
| ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING MOST APTS. ¿ NO RESPONSE. UNABLE TO VERIFY DETECTORS, AND CONDITIONS. UNABLE TO INSPECT ALL ENCLOSED PORCHES. NOTE: UNABLE TO INSPECT INTERIOR COURT YARD AREA. | 5401 S ELLIS AVE | COMPLAINT | FAILED | View |
| RELOCATE SMOKE DETECTOR | APT. 10 /SMOKE DETECTOR - RELOCATE SMOKE DETECTOR INSTALLED TOO LOW 16 INCHES FROM CEILING ON THE WALL. | 5401 S ELLIS AVE | COMPLAINT | FAILED | View |
| REPAIR INTERIOR STAIR SYSTEM | NORTH ELEVATION [AT WEST] /INTERIOR STAIRWELL [GRADE TO 3RD. FL.] - GUARD AND STAIR RAIL SECTIONS - LOOSE AND PULLING. TREADS /GRADE TO 3RD. FL. - LOOSE.NORTH ELEVATION [AT CENTER OF BUILDING] /INTERIOR STAIRWELL [GRADE TO 1ST. FL.] - GUARD AND STAIR RAIL SECTIONS - LOOSE AND PULLING. TREADS /GRADE TO 3RD. FL. - LOOSE.NORTH ELEVATION [AT EAST] /INTERIOR STAIRWELL [GRADE TO 1ST. FL.] - GUARD AND STAIR RAIL SECTIONS - LOOSE AND PULLING. TREADS /GRADE TO 3RD. FL. - LOOSE.EAST ELEVATION [CENTER OF BUILDING] AND SOUTH ELEVATION [AT WEST] /INTERIOR STAIRWELL [GRADE TO 1ST. FL.] - GUARD AND STAIR RAIL SECTIONS - LOOSE AND PULLING. TREADS /GRADE TO 3RD. FL. - LOOSE.PERMIT REQUIRED. | 5401 S ELLIS AVE | COMPLAINT | FAILED | View |
| REPAIR PORCH SYSTEM | NORTH ELEVATION [AT WEST] /3 STORY ENCLOSED PORCH. [REAR OF APT. 10]STAIRS [GRADE TO 3RD. FL.] /TREADS - LOOSE.RAILINGS /STAIR RAILING SECTIONS - LOOSE AND PULLING; DEFLECTING UNDER LOAD; WITH TOP AND BOTTOM RAILS PULLING.EAST ELEVATION /3 STORY OPEN PORCH WITH ROOF.DECK JOISTS [AT 2ND. FL. [APT #32] /DECK JOIST - LOCATED ABOVE EXTERIOR DOOR, WITH OPEN POCKETS AND SHIFTED BRICK.STAIRS /TREADS [2ND. TO 3RD. FL.] - LOOSE, SAGGING - TRIP HAZARD.RAILINGS /STAIR RAILING SECTIONS [GRADE TO 1ST. FL.] - LOOSE AND PULLING; DEFLECTING UNDER LOAD; WITH TOP AND BOTTOM RAILS PULLING.SOUTH ELEVATION /3 STORY OPEN PORCHES WITH ROOF.SOUTH PORCH [AT EAST].COLUMNS /HALF-LAP JOINTS, WITH ONLY 3 BOLT USED OF 1/2 INCHES IN DIAMETER.DECK JOISTS //POCKETS LEFT WITH VOIDS, MORTAR MISSING, WOOD SHIMS LEFT IN PLACE UNDERNEATH JOISTS INSIDE THE JOIST POCKET.SOUTH PORCH [AT WEST].DECK JOISTS //POCKETS LEFT WITH VOIDS, MORTAR MISSING.PERMIT REQUIRED. | 5401 S ELLIS AVE | COMPLAINT | FAILED | View |
| REPAIR EXTERIOR DOOR | WEST ELEVATION /EXTERIOR DOOR - OFF HINGES. | 5401 S ELLIS AVE | COMPLAINT | FAILED | View |
| REPAIR COPING | NORTH ELEVATION /COPING - WASHED OUT MORTAR. | 5401 S ELLIS AVE | COMPLAINT | FAILED | View |
| POST OWNER/MANAGERS NAME/# | BUILDING /OWNER¿S I.D. SIGN ¿ INCOMPLETE ADDRESS POSTED. | 5401 S ELLIS AVE | COMPLAINT | FAILED | View |
| REPAIR EXTERIOR WALL | EAST ELEVATION /EXTERIOR WALL - WASHED OUT MORTAR. | 5401 S ELLIS AVE | COMPLAINT | FAILED | View |
| INSPECT CONSTRUCTION WORK | COORDINATE INSPECTION WITH DEPARTMENT OF BUILDINGS FOR PERMIT # 100582705. | 5401 S ELLIS AVE | COMPLAINT | FAILED | View |
| FILE BLDG REGISTRATION | BUILDING NOT REGISTERED FROM 2016-17. | 5401 S ELLIS AVE | COMPLAINT | FAILED | View |
| REPAIR LINTELS | NORTH AND WEST ELEVATIONS /METAL WINDOW LINTELS - SAGGING, DEFLECTING, WITH GAPS ABOVE IT.PERMIT REQUIRED.MOST WINDOW LINTELS CAPPED WITH METAL, UNABLE TO INSPECT MOST CONDITIONS. NOTE: REMOVE METAL WRAP COVERING LINTELS, WRAP IS CAUSING PREMATURE FAILURE. | 5401 S ELLIS AVE | COMPLAINT | FAILED | View |
| ROACHES | APARTMENT #51 - ROACH INFESTATION . | 5401 S ELLIS AVE | COMPLAINT | FAILED | View |
| REPAIR/REPLACE SMOKE DETECTORS | APARTMENT #51 - SMOKE DETECTOR OUT OF SERVICE DATE . | 5401 S ELLIS AVE | COMPLAINT | FAILED | View |
| REPAIR EXTERIOR DOOR HARDWARE | APARTMENT #51 - REAR DOOR , TENANT HAS NO KEY . | 5401 S ELLIS AVE | COMPLAINT | FAILED | View |
| REPLACE DEFECTIVE PLBG FIXTURE | APARTMENT #51 - BATHROOM SINK RUSTED AND UNSANITARY . | 5401 S ELLIS AVE | COMPLAINT | FAILED | View |
| INSPECT CONSTRUCTION WORK | PERMIT # 1003883054 ISSUED 2/28/2011 FOR PORCH REPAIRS , NO PLANS OR PERMITS AVAILABLE FOR INSPECTORS REVIEW AT TIME OF INSPECTION . | 5401 S ELLIS AVE | PERIODIC | FAILED | View |
| REPAIR EXTERIOR WALL | BRICK AND STONE FRONT ENTRY AT WEST CENTER , DISPLACED BRICKS AND STONES , PARAPET LEANING BACK . MASONRY PERMIT REQUIRED FOR REPAIRS .SOUTHEAST CORNER AT GRADE , SPALLED BRICKS OPEN MORTAR JOINTS . | 5401 S ELLIS AVE | PERIODIC | FAILED | View |
| FILE BLDG REGISTRATION | BUILDING - NOT REGISTERED 2016 YEAR . | 5401 S ELLIS AVE | PERIODIC | FAILED | View |
| REPAIR CORNICE | WEST ELEVATION LIMESTONE AND BRICK CORNICE , OPEN MORTAR JOINTS , WASHED OUT MORTAR . | 5401 S ELLIS AVE | PERIODIC | FAILED | View |
| REPAIR EXTERIOR DOOR, RESET | THREE NORTH PORCH ENTRY DOORS , SAGGING , LOOSE GLASS , NOT FIT IN FRAME . | 5401 S ELLIS AVE | PERIODIC | FAILED | View |
| REPAIR SCREENS | ALL ELEVATIONS AND FLOORS , WINDOW SCREENS , TORN , LOOSE , MISSING , HOLES . | 5401 S ELLIS AVE | PERIODIC | FAILED | View |
| MAINTAIN WINDOW | BASEMENT WOOD WINDOW SCREEN FRAMES ALL ELEVATION ROTTED WITH FLAKING PAINT . | 5401 S ELLIS AVE | PERIODIC | FAILED | View |
| MAINTAIN PROJECTIONS | WEST ELEVATION AT GRADE , IRON WINDOW GRATES RUSTED AND FLAKING PAINT . | 5401 S ELLIS AVE | PERIODIC | FAILED | View |
| ROACHES | BUILDING - ROACH INFESTATION . | 5401 S ELLIS AVE | PERIODIC | FAILED | View |
| CARPETING | FRONT ENTRY STAIRWAYS , CARPETING , TORN , LOOSE , STAINED , ODORS . | 5401 S ELLIS AVE | PERIODIC | FAILED | View |
| REPAIR SKYLIGHT | FRONT ENTRY STAIRWAYS , SKYLIGHTS CRACKED , BROKEN GLASS , LEAKING . | 5401 S ELLIS AVE | PERIODIC | FAILED | View |
| REPAIR INTERIOR WALLS/CEILING | FRONT ENTRY STAIRWAYS , WALLS DIRTY AND STAINED . | 5401 S ELLIS AVE | PERIODIC | FAILED | View |
| STOP/REMOVE NUISANCE | NORTH AND EAST ELEVATION , PHONE AND CABLE LINES , LOOSE , HANGING , BROKEN AND LOOSE RACEWAYS , OPEN CABINETS , ENTANGLEMENT HAZARD . | 5401 S ELLIS AVE | PERIODIC | FAILED | View |
| REPAIR GUTTER & DOWNSPOUT | SOUTH ELEVATION , GUTTERS AND DOWNSPOUTS RUSTED , FLAKING PAINT , LEAKING AT JOINTS . | 5401 S ELLIS AVE | PERIODIC | FAILED | View |
| REPAIR/REPLACE SMOKE DETECTORS | FRONT ENTRY STAIRWAYS , SMOKE DETECTORS OUT OF SERVICE DATE . | 5401 S ELLIS AVE | PERIODIC | FAILED | View |
| DEBRIS, EXCESSIVE | PORCH AREA JUNK AND DEBRIS | 5401 S ELLIS AVE | PERIODIC | PASSED | View |
| OBSTRUCTIONS IN EXIT WAY | APT DOORS BURGLAR BARS | 5401 S ELLIS AVE | PERIODIC | FAILED | View |
| REPAIR EXTERIOR DOOR | DOUBLE FRONT ENTRY DOORS , ROTTED , SAGGING , LOOSE GLASS , NOT FIT IN FRAMES , NOT SEALED FOR AIR INFILTRATION ,REQUIRE REPLACEMENT . | 5401 S ELLIS AVE | PERIODIC | FAILED | View |
| REPAIR EXTERIOR DOOR, RESET | NORTH ELEVATION /EXTERIOR DOORS - TOO SMALL FOR FRAME, WITH GAPS AT BOTTOM. | 5401 S ELLIS AVE | COMPLAINT | FAILED | View |
| REPAIR SCREENS | ALL ELEVATION / SCEEN - MISSING | 5401 S ELLIS AVE | PERIODIC | FAILED | View |
| REPAIR PORCH SYSTEM | EAST ELEVATION / REAR 3 STORY WOOD PORCH / 3RD FLOOR AT WINDERS / GUARDRAIL - LOOSE AT WALL CONNECTION. BOTTOM BRACKET - MISSING NAILS. STAIR TREADS - CRACKED AT WINDERS. SOUTH ELEVATION / EASTERN 3 STORY WOOD PORCH - LOOSE PICKETS.SOUTH ELEVATION / CENTER PORCH - LOOSE PICKETS. | 5401 S ELLIS AVE | PERIODIC | FAILED | View |
| ILLUMINATE EXIT AREAS | SOUTH EELVATION / EASTERN PORCH .LIGHT AT GRADE - NOT ILLUMINATED. NORTH ELEVATION / CENTER PORCH AT 2ND FLOOR / LIGHT - NOT ILLUMINATED. | 5401 S ELLIS AVE | PERIODIC | FAILED | View |
| MAINTAIN WINDOW | NORTH AND WEST ELEVATION / 1ST FL DOOR PANE - MADE OF PVC | 5401 S ELLIS AVE | PERIODIC | FAILED | View |
| REPAIR EXTERIOR DOOR | NORTH ELEVATION CENTER INTERIOR STAIR / EXTERIOR DOOR - DOES NOT LATCH | 5401 S ELLIS AVE | PERIODIC | FAILED | View |
| INSTALL SMOKE DETECTORS | NORTH ELEVATION CENTER INTERIOR STAIR / SMOKE DETECTOR - MISSING .10 YEAR SMOKE REQUIRED . | 5401 S ELLIS AVE | PERIODIC | FAILED | View |
| SCREEN OUTER DOORS, WINDOWS | NORTH ELEVATION CENTER INTERIOR STAIR / SCREEN DOOR - BROKEN | 5401 S ELLIS AVE | PERIODIC | FAILED | View |