Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
ARRANGE PREMISE INSPECTION | NO ENTRY INTERIOR, NO ACCESS INTERIOR PORTION OF REAR PORCHES. | 931 W WINONA ST | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO INTERIOR AND PORCH | 931 W WINONA ST | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH INSUFFICIENT STRINGER CONSTRUCTION, INSUFFICIENT STRINGER ANCHORS. OPEN STRINGER/RISERS. MISSING JOIST HANGERS CENTER 4X4 COLUMN FOR STRINGER WITH NO FOUNDATION, 4X4 IS FLOATING. INSUFFICIENT BEAM TO COLUMNS CONNECTIONS. IMPROPER HANDRAIL DESIGN. INSUFFICIENT RAILING ANCHORS. CANTILERED LANDING BEFORE 3 INSUFFICIENT SUPPORT AND ANCHORS, DOES NOT MEET REQUIREMENTS. PORCH FOUNDATION AND RETAINING WALL WITH FRACTURES UNDER AND AROUND COLUMNS OBTAIN COMPLETE PLANS AND PERMIT. | 931 W WINONA ST | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH INSUFFICIENT STRINGER CONSTRUCTION, INSUFFICIENT STRINGER ANCHORS. OPEN STRINGER/RISERS. MISSING JOIST HANGERS CENTER 4X4 COLUMN FOR STRINGER WITH NO FOUNDATION, 4X4 IS FLOATING. INSUFFICIENT BEAM TO COLUMNS CONNECTIONS. IMPROPER HANDRAIL DESIGN. INSUFFICIENT RAILING ANCHORS. CANTILERED LANDING BEFORE 3 INSUFFICIENT SUPPORT AND ANCHORS, DOES NOT MEET REQUIREMENTS. PORCH FOUNDATION AND RETAINING WALL WITH FRACTURES UNDER AND AROUND COLUMNS OBTAIN COMPLETE PLANS AND PERMIT. | 931 W WINONA ST | PERIODIC | FAILED | View |