The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR EXTERIOR STAIR | FRONT STAIRS GRADE TO 1ST LOOSE RAILS, 4X4 COLUMNS NOT SET ON PROPER FOOTINGS, JOIST TOO SMALL FOR SPAN, NOT PROPERLY ATTACHED TO BUILDING. REAR GRADE TO 1ST LOOSE RAILS NOT PROPERLY ATTACHED TO BUILDING | 816 W MARQUETTE RD | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | OBTAIN PERMITS FOR REPAIRS TO FRONT AND REAR STAIRS. | 816 W MARQUETTE RD | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | REAR BUILDING NO ENTRY | 816 W MARQUETTE RD | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | FRONT BUILDING NO ENTRY | 816 W MARQUETTE RD | COMPLAINT | FAILED | View |
REPAIR CORNICE | FRONT BUILDING FRONT FIRST FLOOR EXTERIOR WINDOW CONFIGURATION HAS BEEN REPLACED WITH DOUBLE SLIDING DOORS | 816 W MARQUETTE RD | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | FRONT BUILDING PROVIDE PLANS AND PERMITS | 816 W MARQUETTE RD | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT BUILDING REAR PORCH GUARD RAIL UNDER 42 INCHES | 816 W MARQUETTE RD | COMPLAINT | FAILED | View |
PROVIDE | FRONT BUILDING OWNER MUST PROVIDE PROOF OF INSURANCE AS REQUIRED BY (13-12-1250C) MINIMUM OF 300.00 LIABILITY INSURANCE ON BUILDING | 816 W MARQUETTE RD | COMPLAINT | FAILED | View |
REPAIR DOWNSPOUT | FRONT BUILDING MISSING DOWNSPOUT NOT CONNECTED TO SEWER | 816 W MARQUETTE RD | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | FRONT BUILDING REPLACE EFFECTIVE LIGHT FIXTURES FORNT AND REAR EXTERIOR ENTRANCES | 816 W MARQUETTE RD | COMPLAINT | FAILED | View |
DEFECTIVE METER EQUIPMENT | FRONT BUILDING REPLACE DEFECTIVE POWER SERVICE WITH RUSTED AND DAMAGED METER SOCKET INSTALL PUBLIC METER | 816 W MARQUETTE RD | COMPLAINT | FAILED | View |
REPAIR DOWNSPOUT | REAR BUILDING MISSING DOWNSPOUT NOT CONNECTED TO SEWER | 816 W MARQUETTE RD | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | REAR BUILDING REPLACE DEFECTIVE LIGHT FIXTURE ON FRONT EXTERIOR | 816 W MARQUETTE RD | COMPLAINT | FAILED | View |
REPAIR ROOF | FRONT PORCH- ROOF CANOPY- ROTTED SHEETING | 816 W MARQUETTE RD | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | DECKING LOOSE AND ROTTED COLUMNS NOT CENTERED ON FOOTINGS, METAL COLUMN CONNECTOR BRACKET MISSING, GUARD RAILS UNDERSIZED UPPER AND LOWER NAILS IMPROPER TOP RAIL ALL AT FRONT PORCH ALSO UNDERSIZED JOIST 2X6 SPANNING OVER 7 FEET SHOULD BE 2 X 6. | 816 W MARQUETTE RD | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT PORCH STAIRS IMPROPERLY FASTENED TO WRONG STRUCTURAL ELEMENT USING METAL CLIPS AND DRYWALL SCREWS TO FASTEN STRINGER TO UNSUPPORTED BEAM, INSUFFICIENT TREAD SIZE. | 816 W MARQUETTE RD | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | 816 W MARQUETTE RD | COMPLAINT | FAILED | View | |
UNINTERRUPTED EXIT AT GRADE | SIDE GATE LOCATED WITH CHAIN. | 816 W MARQUETTE RD | COMPLAINT | FAILED | View |
PROVIDE | FRONT BUILDING OWNER HAS NOT REGISTERED VACANT BUILDING AS REQUIRED BY (13-12-125A) | 816 W MARQUETTE RD | COMPLAINT | FAILED | View |
FRONT BUILDING (18-27-210.8) INSTALL GFCI ON EXTERIOR OF BUILDING | 816 W MARQUETTE RD | COMPLAINT | FAILED | View | |
REPAIR PORCH SYSTEM | REAR BUILDING REAR PORCH EXTERIOR WEST VERTICAL POST NOT SECURED | 816 W MARQUETTE RD | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR BUILDING FRONT EXTERIOR STAIRS MISSING HAND RAILS | 816 W MARQUETTE RD | COMPLAINT | FAILED | View |